Extron electronic HSA 822 user manual Maintenance and Modifications, cont’d Replacing the Bezels

Page 16

Maintenance and Modifications, cont’d

Replacing the Bezels

The HSA 822 ships with RJ-45 connector bezel plug-ins in a variety of colors and a black, blank bezel. Replace a bezel as follows:

1.

Remove the top and bottom screws on the right and left

 

sides of the AAP panel (figure 3-1). Retain the screws. Lift

 

the panel away from the enclosure as far as the connected

 

cables allow and then allow the panel to dangle,

 

supported by its connected cables.

 

The center screws on each side of the AAP panel do not

 

fasten the AAP panel in place. They secure the

 

AC power outlet.

 

Ensure that the edges of the AAP panels do not scratch

 

the finished surface of the top panel flange when

 

removing the panels.

2.

With a tweeker, push down on and

 

gently twist on the front of each RJ-45

 

connector detent to disconnect the

 

connector from the rear of the AAP panel

 

plug-in.

3.

Pinch the top and bottom bezel detents

 

together and push the bezel through the

 

AAP panel.

4.

Snap a replacement bezel in place. If

 

necessary, replace the connector icon by

 

prying the old icon off of the connector plug-in with a

 

tweeker (figure 3-3) and snapping a new icon in place.

Icon Labels

Figure 3-3 — Changing the connector icon

5. Replace the AAP panel in the surface mount enclosure and secure it in place with the screws removed in step 1. If you lose an AAP panel screw, four spare screws are stored in the underside of the enclosure.

Removing and Replacing the Enclosure

The procedures for replacing the gas lift and adjusting the levelling of the top surface require removing the HSA 822 from the table. Remove and replace the surface mount enclosure for maintenance as follows:

 

 

 

Ensure that AC power is disconnected before

 

 

 

servicing the HSA unit.

1.

On the underside of the clamshell and in the enclosure, cut

 

the tie wraps that route the AAP cables out of the way.

2.

Disconnect the IEC power cord and RJ-45 connectors from

 

the underside of the surface mount enclosure.

3.

On both AAP panels, remove the top and bottom screws

 

on the right and left sides of the AAP panel (figure 3-1,

 

page 3-2). Retain the screws. Lift the panels away from

 

the enclosure as far as the connected cables allow and then

 

allow the panels to dangle, supported by their connected

 

cables.

 

 

 

The center screws on each side of the AAP panel do not

 

 

 

 

fasten the AAP panel in place. They secure the AC

 

 

power outlet.

 

 

Ensure that the edges of the AAP panels do not

 

CAUTION

 

 

 

scratch the finished surface of the top panel flange

 

 

 

or the furniture in which the HSA 822 is installed

 

 

 

when removing the panels.

4.

To ensure that the bottom RJ-45 connectors match up with

 

the AAP panel RJ-45 connectors when the maintenance is

 

complete, tag the internal CAT 6 cables to define their

 

installation location (top or bottom and side A or B).

 

Also tag the side of the enclosure itself (A or B).

5.

With a tweeker, inside the AAP panels,

 

push down on and gently twist on the

 

front of each RJ-45 connector detent to

 

disconnect the connector from the rear of

 

the AAP panel plug-in.

6.

Disconnect any cables from the rear of

 

the existing AAPs. Carefully pull the

 

cables through and out the bottom of the

 

surface mount enclosure.

7.

Set the AAP panels aside.

3-4 HSA 822 Hideaway® Enclosure • Maintenance and Modifications

HSA 822 Hideaway® Enclosure • Maintenance and Modifications 3-5

Image 16
Contents Hideaway Surface Access Enclosure HSAPrecautions Extron’s WarrantyPage Table of Contents Introduction Table of Contents, cont’dHSA 822 Hideaway Enclosure Introduction About the HSA 822 Hideaway EnclosureFeatures InstallationIntroduction, cont’d Installation Overview InstallationPreparing the Routing Template Other installation surface. Mark the location Place the routing template assembly on the table, centeredOnce the template assembly is positioned properly, secure Assembly to the table with C-clamps figureInstallation, cont’d Clean the HSA. Strong solvents will ruin someDo not use isopropyl alcohol or other solvents to FinishesInstallation, cont’d Cabling and Installing the AAPs Bottom panel features Installation, cont’d Cabling the EnclosureAn RJ-11 telephone plug can be connected to the RJ-45 jack Installation, cont’d Routing the AAP Cables BezelsMaintenance and Modifications ThreeMaintenance and Modifications Replacing an AAPMaintenance and Modifications, cont’d Replacing the Bezels Removing and Replacing the EnclosureMaintenance and Modifications, cont’d Replacing the Gas Lift Insert the shaft end of the replacement gas lift through Reconnect the interior AC power cablesWith the top panel bracket detached from the lifting Platform, the bracket will be floppy atop the gas liftAdjusting the height of the top surface Height adjustment locking screw slotsAdjusting the top surface level Reference InformationSpecifications Reference InformationPart Numbers GeneralTemplate, Replacement Parts, and Accessories Interface AccessoriesTop Plate Dimensions Reference Information, cont’d Included PartsPackaging for Shipment Reference Information, cont’dPackaging for Shipment Figure B-1 HSA 822 return kitFigure B-3 Installing protective strips Packaging for Shipment, Cont’dFigure B-6 Placing the HSA in the shipping carton Packaging for Shipment, Cont’d