Tripp Lite UL2601-1 owner manual UL Classification for Medical Equipment

Page 10

Specifications

Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

 

 

OMNISMART350HG

OMNISMART450HG

OMNISMART700HG

Output Capacity (VA/Watts):

330/225

450/280

700/425

Battery Runtime

 

 

 

(Half Load/Full Load) Minutes:

46/18

38/14

22/9

Battery Recharge Time:

2-4 hrs.

2-4 hrs.

2-4 hrs.

Approvals:

UL1778, UL2601-1

UL1778

UL1778

 

FCC Class B and Part 68

FCC Class B

FCC Class B

Modem/Fax Protection:

2 lines

None

None

External Battery Type:

None

None

None

 

SMART700HG

SMART1200XLHG

Output Capacity (VA/Watts):

700/450

1000/750

Battery Runtime

 

 

(Half Load/Full Load) Minutes:

42/18

28+/11+

Battery Recharge Time:

2-4 hrs.

2-4 hrs.

Approvals:

UL1778, UL2601-1

UL1778, UL2601-1

 

FCC Class A

FCC Class A

Modem/Fax Protection:

None

None

External Battery Type:

None

BP36V27

ALL MODELS:

 

 

Input Voltage/Frequency (120V/60 Hz); Output Waveform Line Mode (filtered sinewave); Output Waveform Battery Mode (PWM sine wave); AC Surge Suppression (exceeds IEEE 587 Cat. A & B standards); AC Noise Attenuation (>40 dB); AC Protection Modes (H to N, H to G, N to G).

UL CLASSIFICATION FOR MEDICAL EQUIPMENT:

Class I, Type B, Ordinary Equipment, Continuous Operation.

UL1778 APPROVAL:

All the UPS systems described in this manual are UL1778 listed. All meet strict requirements for UPS protection. They provide battery backup during blackouts, switching between utility power and battery backup power in 2-4 milliseconds. All are designed to produce extremely low leakage to ground. In addition, all have hospital-grade plugs and receptacles that reduce the possibility of accidental equipment disconnection. All are suitable for use in hospitals, outside patient care areas.

UL2601-1 APPROVAL:

Several of the UPS models described in this manual are UL 2601-1 listed (see specifications). They incorporate Faraday-shielded isola- tion transformers that reduce the cumulative leakage current of all connected equipment to below 300 microamps. These models are suitable for use in hospitals, including inside patient care areas.

FCC CLASS A RADIO/TV INTERFERENCE NOTICE:

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when operated in a com- mercial environment. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. Operation of this equipment is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The user must use shielded cables and connectors with this product. Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

FCC CLASS B RADIO/TV INTERFERENCE NOTICE (U.S. ONLY):

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference using one or more of the following measures: reorient or relocate the receiving antenna; increase the separation between the equipment and the receiver; connect the equipment into an outlet on a circuit different from that which the receiver is connected; consult the dealer or an experienced radio/television technician for help. The user must use shielded cables and connectors with this product. Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

10

Image 10
Contents SmartPro & OmniSmart UPS Connection Warnings Important Safety InstructionsUPS Location Warnings Equipment Connection WarningsBattery Warnings Select UPS Operating Mode Plug your equipment into Your UPSQuick Installation optional External Batteries Select Models OnlyButtons Indicator Lights Other UPS Features Storage ServicePower Sensitivity Adjustment Select Models Only Automatic Voltage RegulationUL Classification for Medical Equipment 93-2010 Page Manual de operación Advertencias sobre la conexión del UPS Importantes instrucciones de seguridadAdvertencias sobre la colocación del UPS Advertencias sobre la conexión del equipoImportantes instrucciones de seguridad continuación Advertencias sobre las bateríasSistema UPS Enchufe su equipo alSelección del modo de Operación del UPS Instalación rápida optativa Baterías externas Sólo para algunos modelosBotones Luces indicadoras Operación básica continuaciónVoltage Regulation regulación de voltaje, sólo para Otras características del sistema UPS Conexión equipotencial sólo para ciertos modelos Fusible de entrada sólo para ciertos modelosRegulación automática de voltaje Almacenamiento ServicioFicha técnica continuación Certificación UL2601-1Page Guide de lutilisateur Mises en garde relatives au raccord du système UPS Mises en garde relatives à lemplacement du système UPSImportantes consignes de sécurité Mises en garde relatives au raccord de léquipementImportantes consignes de sécurité suite Mises en garde relatives à la batterieChoix du mode dexploitation du système UPS Branchez votre matériel à votre système UPSInstallation rapide facultative Batteries externes Configurations Prédéterminées seulementCommutateurs Exploitation de base suite « Battery Power » alimentation de batterie Ce voyantVoyants lumineux Autres fonctions Port USB configurations prédéterminées seulementPorte de remplacement de la batterie Bornes c.a. de qualité hôpitalRégulation de tension automatique Entreposage EntretienSpécifications suite Homologation UL2601-193-2010

UL2601-1 specifications

The Tripp Lite UL2601-1 is a highly regarded medical-grade power conditioner and surge protector designed to meet the demanding requirements of healthcare environments. Specifically engineered to protect sensitive electronic equipment, this device ensures both safety and performance in clinical settings where equipment reliability is paramount.

One of the standout features of the UL2601-1 is its compliance with various safety standards, including UL 60601-1 and IEC 60601-1. These certifications guarantee that the device meets stringent criteria for electrical safety, critical for protecting both patients and healthcare professionals when using medical devices such as monitors, imaging machines, and more.

The Tripp Lite UL2601-1 offers 6 NEMA outlets, providing ample capacity to manage multiple devices. Each outlet is magnetically isolated to prevent electrical noise, ensuring that sensitive medical equipment operates without interference. Additionally, the built-in 2,400 joules surge protection helps safeguard against power spikes that could cause damage to connected devices.

Another notable technology feature of the UL2601-1 is its EMI/RFI suppression. This system effectively filters electromagnetic and radio frequency interference, significantly enhancing the performance of medical devices by maintaining signal integrity. The device also includes a detachable power cord, which makes it easy to replace in the event of wear and tear while providing flexibility in installation.

In terms of user-friendly characteristics, the Tripp Lite UL2601-1 is equipped with a front-panel LED indicator that monitors power and surge protection status. This feature enables users to quickly ascertain the operational health of the device, further enhancing the reliability of the system in sensitive environments.

The compact design of the UL2601-1 allows for versatile placement options, whether it’s on a countertop, in a medical cart, or mounted in a rack. Additionally, the device is built for durability, featuring a robust housing that can withstand the rigors of a clinical atmosphere.

In summary, the Tripp Lite UL2601-1 is an essential solution for healthcare facilities looking to ensure the safety and efficacy of their medical equipment. With its advanced features, safety certifications, and user-friendly characteristics, it stands as a reliable choice for medical professionals dependent on protecting their sensitive electronic devices.