TOA Electronics FPS-S1U, FPS1000-24 Series operation, Remote On/Off control at parallel operation

Page 39

13.1.4 Remote On/Off control at parallel operation

The paralleled racks can be turned On or Off via a single On/Off control. Refer to Fig 13-5 for typical application. The Signal Return function of all the paralleled racks should be connected together to create a common Signal Return bus. The Signal Return bus may be connected to the -V or the +V potential or floated. In any case do not connect the Signal Return bus to different potentials.

ON/OFF

 

FPS-S1U #1 A, B, C 5, 15, 25

2.6 mA / Installed unit

 

SIG.

 

 

 

RETURN

11

 

 

 

2.6 mA / Installed unit

 

 

ON/OFF

5, 15, 25

 

FPS-S1U #2

A, B, C

 

 

SIG.

ON

OFF

 

RETURN

11

 

 

ON/OFF

5, 15, 25

 

 

 

 

FPS-S1U #3

A, B, C

2.6 mA / Installed unit

 

 

SIG.

11

 

 

RETURN

 

 

Fig 13-5: Remote On/Off control at parallel operation

13.2 Series operation

Two FPS-S1U racks with the same output voltage rating can be connected in series to increase the output voltage or to create a bipolar voltage source. It is recommended to connect diodes in parallel with each output to prevent reverse voltage in case of failure in one of the power supplies.

Each diode should be rated to at least the power supply rated output voltage and output current. Refer to Fig 13-6 and 13-7 for a typical series connection of power supplies.

CAUTION

Series operation is not applicable for units with I2C bus option.

FPS-S1U #1

 

+S

 

+V

 

 

 

 

 

ON/ ON/

ON/

(*)

 

-V

SIG. OFF OFF OFF

-S

RTN

A

B

C

11

5

15

25

 

FPS-S1U #2

 

+S

 

+V

 

 

 

 

 

ON/ ON/

ON/

(*)

 

-V

SIG. OFF OFF OFF

RTN

A

B

C

-S

11 5 15 25

+S

+V

LOAD

-V

-S

(*) Diodes are user supplied

Fig 13-6: Series connection for increased output voltage

FPS-S1U #1

 

+S

 

+V

 

 

 

 

 

ON/ ON/

ON/

(*)

 

-V

SIG. OFF OFF OFF

RTN

A

B

C

-S

11

5

15

25

 

FPS-S1U #2

 

+S

 

+V

 

 

 

 

 

ON/ ON/

ON/

(*)

 

-V

SIG. OFF OFF OFF

RTN

A

B

C

-S

+V LOAD

COMMON

-V

11

5 15 25

(*) Diodes are user supplied

Fig 13-7: Series connection for Bipolar output voltage

36

Image 39
Contents FPS Series 1000W In 1U FPS1000 Series Table of Contents Disclaimer WarrantyLimitation of Warranty Warranty ServiceFPS1000 Power Supply and FPS-S1U Rack Safety Instructions Safety Symbols FPS1000 Series Specifications Outline Drawings FPS 1000 Series Outline Drawings FPS 1000/P Series Outline Drawings FPS1000 Power Supply Installation Connecting the Load Load WiringCurrent Carrying Capacity Noise and Impedance Effects Inductive loadsMaking the load connections Repackaging for Shipment Input/Output connector informationFunctions and Features FPS10004.7KΩ Dcok signalACFail signal Remote On/Off controlRemote Sensing Basic Connections for Operation Connecting single load, Local sensingConnecting Single Load, Remote Sensing Connecting Multiple loads, radial distribution methodGrounding outputs Multiple loads connection with distribution terminalsOutput voltage trimming at parallel operation Parallel and Series OperationParallel operation Parallel operation with Remote sensingRemote On/Off control at parallel operation Signal Return bus at parallel operationSeries connection for positive and negative output voltage Series operationI2C BUS Interface Option Block diagram of the I2C option Operation and functions 7.4.1. Digital statusEeprom functions Analog functions 4 A/D ScalingOutput current readback FPS1000 Typical application diagramFPS1000 Maintenance FPS-S1U 19 Rack Single Output Maximum output power Chapter FPS-S1U Rack SpecificationsFPS-S1U Rack Mounting FPS-S1U Rack InstallationRear panel description Control and monitoring signals connectorSCL I2C Blank panels Modules locationFPS-S1U and FPS-S1U/P Outline Drawings FPS-S1U/P Outline Drawing Multiple loads connection Basic Connections for Operation FPS-S1U RackSupervisory signals 12.4 On/Off controlOutput voltage trimming Parallel operation with Remote sensing Output voltage trimming at parallel operation Signal Return bus at parallel operationRemote On/Off control at parallel operation FPS-S1U I2C BUS Interface Option IntroductionAddressing A0, A1, A2 Adjustments and Calibration FPS-S1U MaintenanceUnits under warranty Periodic maintenanceFPS-T1U 19 Rack Triple Output Chapter FPS-T1U Rack SpecificationsFPS-T1U Rack Mounting FPS-T1U Rack InstallationFPS-T1U Rear panel J1A, J2B, J3C Conector Description Modules location FPS-T1U and FPS-T1U/P Outline Drawings FPS-T1U/P Outline Drawing 19.2 On/Off control Basic Connections for Operation FPS-T1U RackOutput Voltag Trimming Load Series operation Module a Module B Module C FPS-T1U I2C BUS Interface OptionFPS-T1U Maintenance