TOA Electronics FPS1000-24, FPS1000-12, FPS1000-32, FPS-S1U, FPS-T1U, FPS1000-48 Safety Symbols

Page 6

FPS1000 Instruction Manual

ATTENTION:

Risque de choc et de danger e'lectriques. Le de'branchement d'une seule alimenttation stabilise'e ne de'branche uniquement qu'un module "Alimentation Stabilise'e".

Pour isoler completement le module en cause, il faut de'brancher toutes les alimentations stabilise'es.

SAFETY SYMBOLS

CAUTION Risk of Electrical Shock.

Instruction manual symbol. The instrument will be marked with this symbol when it is necessary for the user to refer to the instruction manual.

Indicates hazardous voltage.

Indicates ground terminal.

Protective Ground Conductor Terminal

Denotes hazard. An attention to a procedure is called. Not following the procedure correctly could result in personal injury. A WARNING sign should not be skipped and all indicated conditions must be fully understood and met.

Denotes hazard. An attention to a procedure is called. Not following the procedure correctly could result in damage to the equipment.

ENERGY HAZARD

The FPS1000, FPS-S1U and the FPS-T1Uproducts are capable of providing hazardous energy.

Manufacturers final equipment must provide protection to service personnel against inadvertent contact with these models output terminals. If set such that hazardous energy can occur then the output terminals or connections therefore must not be user accessible.

OVERCURRENT PROTECTION:

A readily accessible Listed branch circuit overcurrent protective device rated 20 A must be incorporated in the building wiring.

SERIAL OPERATION

The FPS-T1U product is capable of providing hazardous voltage output in case of the serial connection of two or more FPS1000 units in the rack. Manufacturers final equipment must provide protection to service personnel against inadvertent contact with these models output terminals. If set such that hazardous voltage can occur then the output terminals or connections therefore

FUSES

There are no user replaceable fuses in the FPS1000, FPS-S1U and the FPS-T1Uproducts. Internal fuses are sized for fault protection and if a fuse was opened it would indicate that service is required. Fuse replacement should be made by qualified technical personnel.

FPS-S1U and FPS-T1U racks contains no fuses. FPS1000 fuses rating are described below. F101: F20A H 250Vac

F102: 6.3A 400Vdc

SICHERHEITSHINWEISE

Vor Anschluss an die Netzversorgung ist die Aufstellanleitung zu beachten!

1.Absicherung: F101: F20A H 250VAC, F102: 6.3A 400VDC

2.Der maximale Ableitstrom der Gesamtanlage darf 3.5mA nicht ueberschreiten.

3.Die Gehaeuseabdeckung darf nur im stromlosen Zustand geoeffnet werden.

ACHTUNG:

Sicherungen duerfen nur durch geschulte Service Personen getauscht werden.

3

Image 6
Contents FPS Series 1000W In 1U FPS1000 Series Table of Contents Warranty Service WarrantyLimitation of Warranty DisclaimerFPS1000 Power Supply and FPS-S1U Rack Safety Instructions Safety Symbols FPS1000 Series Specifications Outline Drawings FPS 1000 Series Outline Drawings FPS 1000/P Series Outline Drawings FPS1000 Power Supply Installation Connecting the Load Load WiringCurrent Carrying Capacity Noise and Impedance Effects Inductive loadsMaking the load connections Input/Output connector information Repackaging for ShipmentFunctions and Features Remote On/Off control Dcok signalACFail signal FPS10004.7KΩRemote Sensing Connecting Multiple loads, radial distribution method Connecting single load, Local sensingConnecting Single Load, Remote Sensing Basic Connections for OperationMultiple loads connection with distribution terminals Grounding outputsParallel operation with Remote sensing Parallel and Series OperationParallel operation Output voltage trimming at parallel operationSignal Return bus at parallel operation Remote On/Off control at parallel operationSeries operation Series connection for positive and negative output voltageI2C BUS Interface Option Block diagram of the I2C option Operation and functions 7.4.1. Digital statusEeprom functions Analog functions 4 A/D ScalingOutput current readback Typical application diagram FPS1000FPS1000 Maintenance FPS-S1U 19 Rack Single Output Chapter FPS-S1U Rack Specifications Maximum output powerFPS-S1U Rack Installation FPS-S1U Rack MountingControl and monitoring signals connector Rear panel descriptionSCL I2C Modules location Blank panelsFPS-S1U and FPS-S1U/P Outline Drawings FPS-S1U/P Outline Drawing Basic Connections for Operation FPS-S1U Rack Multiple loads connectionSupervisory signals 12.4 On/Off controlOutput voltage trimming Parallel operation with Remote sensing Signal Return bus at parallel operation Output voltage trimming at parallel operationRemote On/Off control at parallel operation FPS-S1U I2C BUS Interface Option IntroductionAddressing A0, A1, A2 Periodic maintenance FPS-S1U MaintenanceUnits under warranty Adjustments and CalibrationFPS-T1U 19 Rack Triple Output FPS-T1U Rack Specifications ChapterFPS-T1U Rack Installation FPS-T1U Rack MountingFPS-T1U Rear panel J1A, J2B, J3C Conector Description Modules location FPS-T1U and FPS-T1U/P Outline Drawings FPS-T1U/P Outline Drawing Basic Connections for Operation FPS-T1U Rack 19.2 On/Off controlOutput Voltag Trimming Load Series operation FPS-T1U I2C BUS Interface Option Module a Module B Module CFPS-T1U Maintenance