Network Technologies SM-nXm-15V-LCD operation manual RS232 Control, Scan Mode, Remote Connection

Page 12

NTI VEEMUX VIDEO MATRIX SWITCH

Scan Mode

Scan Mode causes an output port to automatically switch from one input port to the next consecutive input port after a specified period of time (referred to as the dwell time). Port switching will continue indefinitely and no ports will be skipped, whether there are video sources connected to them or not. If desired, the VEEMUX can be configured to skip the scanning of specific ports using the RS232 Command Protocol (page 9) or Telnet (page 13).

Dwell time settings can be any value from 0 seconds (000) to 255 seconds. A setting of 000 seconds (the default setting) disables Scan Mode for that output port. If Scan Mode is disabled for a specific port, then the video to that output will only change as decided by the administrator.

To configure Scan Mode from the front panel LCD:

Press MENU, the following lines will be displayed:

1)Set Baud Rate

2)Set Unit Addr

Press MENU again, the following line will be displayed:

3)Set Scan Mode

Press 3 to select that menu item. The following request will be displayed:

Select Port

Select the output to be programmed using the numeric keys, then press ENTER. The display will show the current Dwell Time value for that output and ask for a new value.

Current Time: 16

New Time:

Using the numeric keys, enter a value between 0 and 255 and press ENTER. Leading zeros are allowed (000) but the number should not exceed 3 digits. The Scan Mode dwell setting value 0 will disable Scan Mode for that output port.

Scan Mode settings can also be configured through the RS232 Command Protocol (page 10), Telnet commands (page 13), or through the Web Interface (page 18).

NOTE: Scan Mode configuration settings can only be saved if they are assigned a memory location via the Keypad Control (page 7). Otherwise when the power is cycled to the VEEMUX, all Scan Mode settings will be erased.

TIP: If the Scan mode settings are stored as memory location 0, they will be loaded each time the VEEMUX is powered ON.

RS232 Control

RS232 enables the VEEMUX to be remotely controlled via RS232. To control the VEEMUX via RS232 the user has three options:

write a program that runs on a PC using the Command Protocol (page 9)

use the Matrix Switcher's Control Program (page 11) provided on the CD

use the SerTest program (page 11) provided on the CD

Remote Connection

The RS232 Interface is designed to control the switch via serial (RS232) daisy chain connection from any host computer or other controller with an RS232 communications port. There is, however, a restriction that must be followed:

The pin outs for the DB-9 connector on the unit are as follows:

RS232 Connector (DB-9 FEMALE)

PIN

SIGNAL

FUNCTION

PIN

SIGNAL

FUNCTION

1

None

no connection

6

DTR

Data Terminal Ready

2

TXD

Transmit Data (RXD at host)

7

CTS

Clear to Send

3

RXD

Receive Data (TXD at host)

8

RTS

Request to Send

4

DSR

Data Set Ready

9

none

no connection

5

GND

Signal Ground

 

 

 

8

Image 12
Contents SM-nXm-15V-LCD Trademark Table of Contents Table of Figures Introduction Basic OperationSupported Web Browsers CompatibiltyDefault User Name and Passwords MaterialsCables Materials Supplied with this kitFeatures and Functions Power ON/OFF switchFront View of SM-8X8-15V-LCD Installation Connect the Sources and Monitors9D-male RS232 connector Connect RS232Connect to the Ethernet Power Up LED MatrixControl Options Front Panel LCD with Keypad ControlEscape back to the main display Used to enter numbers. # Output user number can be enteredScan Mode RS232 ControlRemote Connection Command Protocol Baud RateUnit Address RS232 Matrix-Y-1 CPU Serial PortCommand Definitions Contd AutostatusSerTest- RS232 Interface Test Program Main OptionsMatrix Operations Setup Options Ethernet OperationsCommand Reply Description Ethernet ControlTelnet Interface Telnet 192.168.1.30Enter the Password Web InterfaceVideo Switch Web interface SwitchSetup Pages Web interface SetupWeb interface Serial Setup Video Input NamesScan Mode Output NamesUpdate Firmware Web interface Update FirmwareChange Password Update Web ServerHelp Logout Web interface LogoutDevice Discovery Tool Device Discovery ToolFeatures And Functions Infrared ControlKeypad LCD DisplayHow To Use The IRT Change the SwitchPower on with SYS, in or OUT keys Power on with 2 key Change Output Port Change Input PortSet Configuration Battery Replacement SpecificationsIRT Troubleshooting Insert 2 new AA cell batteriesDDC Support RS232 Upgrade of the Front Panel LCD Firmware Following will be neededNTI Veemux Video Matrix Switch RS232 Connection Cables Pinout of RS232 port on VeemuxWiring Schematic of Matrix-Y-1 cable Arrows indicate signal directionPinout for Matrix Y-1 Cable Rack Mounting InstructionsSpecifications NTI Desktop Size Rack Units Rack Size In. WxDxHTroubleshooting Safety StatementsWarranty Information Index