Network Technologies SM-nXm-15V-LCD operation manual Ethernet Operations, Setup Options

Page 16

NTI VEEMUX VIDEO MATRIX SWITCH

Ethernet Operations

Key Selection

1)Set Unit IP Address

2)Set Unit Subnet Mask

3)Set Unit Default Gateway

4)Set Unit Website Timeout

5)Read Unit IP Address

6)Read Unit Subnet Mask

7)Read Unit Default Gateway

8)Read Unit Website Timeout

Description

-enter the desired IP address in xxx.xxx.xxx.xxx format

-number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are accepted

-enter the desired IP address in xxx.xxx.xxx.xxx format

-number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are accepted

-enter the desired default gateway

-number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are accepted

-set the website timeout; timeout = numeric string of timeout in seconds

- Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800 0 = no timeout

-read the unit IP address in xxx.xxx.xxx.xxx format

-read the unit subnet mask in xxx.xxx.xxx.xxx format

-read the unit default gateway in xxx.xxx.xxx.xxx format

-read the current website timeout period in seconds

- Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800 0 = no timeout

Setup Options

Key Selection

1)select Com port current: (COM1:)

2)select Baud rate current: (9600)

3)set unit Address current:

(1)

Description

-select PC serial port

-the current PC serial port is displayed in parentheses

-select PC serial port baud rate

-the current baud rate is displayed in parentheses

-select the unit address

-the current address is displayed in parentheses

For any selection that requires user input, the user is prompted. When commands are sent to the matrix unit, the command string and matrix unit responses are echoed to the screen. All commands generated by the program are formatted according to the information provided in sections above. If any transmission problems are detected, an error message is displayed.

Press <Esc> or <Enter> to back out to the main menu and press again to exit.

12

Image 16
Contents SM-nXm-15V-LCD Trademark Table of Contents Table of Figures Introduction Basic OperationSupported Web Browsers CompatibiltyDefault User Name and Passwords MaterialsCables Materials Supplied with this kitPower ON/OFF switch Features and FunctionsFront View of SM-8X8-15V-LCD Installation Connect the Sources and MonitorsConnect RS232 9D-male RS232 connectorConnect to the Ethernet Power Up LED MatrixControl Options Front Panel LCD with Keypad ControlEscape back to the main display Used to enter numbers. # Output user number can be enteredRS232 Control Scan ModeRemote Connection Command Protocol Baud RateUnit Address RS232 Matrix-Y-1 CPU Serial PortCommand Definitions Contd AutostatusMain Options SerTest- RS232 Interface Test ProgramMatrix Operations Setup Options Ethernet OperationsCommand Reply Description Ethernet ControlTelnet Interface Telnet 192.168.1.30Enter the Password Web InterfaceVideo Switch Web interface SwitchSetup Pages Web interface SetupWeb interface Serial Setup Video Input NamesScan Mode Output NamesUpdate Firmware Web interface Update FirmwareUpdate Web Server Change PasswordHelp Logout Web interface LogoutDevice Discovery Tool Device Discovery ToolFeatures And Functions Infrared ControlKeypad LCD DisplayChange the Switch How To Use The IRTPower on with SYS, in or OUT keys Power on with 2 key Change Output Port Change Input PortSet Configuration Battery Replacement SpecificationsIRT Troubleshooting Insert 2 new AA cell batteriesDDC Support RS232 Upgrade of the Front Panel LCD Firmware Following will be neededNTI Veemux Video Matrix Switch RS232 Connection Cables Pinout of RS232 port on VeemuxWiring Schematic of Matrix-Y-1 cable Arrows indicate signal directionPinout for Matrix Y-1 Cable Rack Mounting InstructionsSpecifications NTI Desktop Size Rack Units Rack Size In. WxDxHTroubleshooting Safety StatementsWarranty Information Index