Network Technologies SM-nXm-15V-LCD Ethernet Control, Telnet Interface, Telnet 192.168.1.30

Page 17

NTI VEEMUX VIDEO MATRIX SWITCH

ETHERNET CONTROL

Telnet Interface

The Telnet Interface enables the user to control the switch using telnet client through an Ethernet connection. The telnet server listens on port 2000. To access the telnet interface, using the current IP address type the following in a command shell:

telnet 192.168.1.30 2000

The VEEMUX will prompt the user for a password. The user must enter the password followed by <Enter>.

The factory default password is "admin".

With a proper password sent the VEEMUX will respond with:

Password Successful

Connection Established

The following commands are now available:

 

Command

 

Reply

 

Description

 

 

 

 

 

 

 

H(elp) or

 

Displays the list of

 

Help

 

h(elp)

 

commands

 

 

 

 

 

 

 

 

User is prompted to

 

 

 

CP

 

introduce the password

 

Change password

 

 

 

twice

 

 

 

CS nn,mm

 

*<CR>

 

Connect One Output (User Port) To Input (Video source)

 

 

 

 

 

 

 

CA nn

 

*<CR>

 

Connect All Outputs To Input

 

 

 

 

 

 

 

RO nn

 

*<CR>mm<CR>

 

Read Connection For Output.

 

 

 

Returns the number of the input (mm) connected to output nn

 

 

 

 

 

 

CC nn

 

*<CR>nn<CR>

 

Save Matrix Connections Into Memory Bank nn

 

 

 

nn should be between 00 and 99

 

 

 

 

 

 

RC nn

 

*<CR>nn<CR>

 

Restore Matrix Connections From Memory Bank nn

 

 

 

nn should be between 00 and 99

 

 

 

 

 

 

CB nn

 

*<CR>

 

Change baud rate of serial line, nn=12(00),24(00),48(00),96(00)

 

 

 

Factory default is 9,600.

 

 

 

 

 

 

RS

 

*<CR>

Reset Unit

 

 

 

 

 

 

RV 00

 

*<CR>string\0<CR>

Read NTI Version String

 

 

 

 

 

 

 

RU

 

*<CR>nn,mm<CR>

 

Read Unit Size

 

 

 

Returns the number of inputs(nn) and the number of outputs (mm)

 

 

 

 

 

 

Ss nn,dwt

*<CR>

 

Set value of Scan Mode dwell time (see pg. 8) for specific Output (nn)

 

 

dwt = 000-255 (seconds) 000= disable Scan Mode

 

 

 

 

 

 

Gs nn

 

*<CR>

 

Read set Scan Mode dwell time value (dwt) for specific Output (nn) in

 

 

dwt<CR>

 

seconds (see also "Scan Mode" on page 8)

 

 

 

 

 

Sa nn,mm

 

*<CR>

 

Set scan list of individual output nn to all inputs mm

 

 

 

 

 

 

 

Sc nn

 

*<CR>

 

Clear scan list of individual output nn

 

 

 

 

 

 

S+ nn,mm

*<CR>

 

Add input mm to Scan List of output nn

 

 

 

 

 

 

 

S- nn,mm

 

*<CR>

 

Remove input mm from Scan List of output nn

 

 

 

 

 

 

 

Sx nn

 

*<CR>oooxoxxxooooxxx<

 

Display the Scan List of output nn (o=skip x=don't skip)

 

 

CR>

 

 

 

 

 

 

 

<Ctrl>-<X>

 

Good Bye.

 

Quit telnet session

 

(see note 4 below)

 

Connection to host lost.

 

 

 

 

 

13

Image 17
Contents SM-nXm-15V-LCD Trademark Table of Contents Table of Figures Basic Operation IntroductionSupported Web Browsers CompatibiltyMaterials Default User Name and PasswordsCables Materials Supplied with this kitFront View of SM-8X8-15V-LCD Features and FunctionsPower ON/OFF switch Connect the Sources and Monitors InstallationConnect to the Ethernet 9D-male RS232 connectorConnect RS232 LED Matrix Power UpFront Panel LCD with Keypad Control Control OptionsEscape back to the main display Used to enter numbers. # Output user number can be enteredRemote Connection Scan ModeRS232 Control Baud Rate Command ProtocolUnit Address RS232 Matrix-Y-1 CPU Serial PortAutostatus Command Definitions ContdMatrix Operations SerTest- RS232 Interface Test ProgramMain Options Ethernet Operations Setup OptionsEthernet Control Command Reply DescriptionTelnet Interface Telnet 192.168.1.30Web Interface Enter the PasswordWeb interface Switch Video SwitchWeb interface Setup Setup PagesVideo Input Names Web interface Serial SetupOutput Names Scan ModeWeb interface Update Firmware Update FirmwareHelp Change PasswordUpdate Web Server Web interface Logout LogoutDevice Discovery Tool Device Discovery ToolInfrared Control Features And FunctionsKeypad LCD DisplayPower on with SYS, in or OUT keys Power on with 2 key How To Use The IRTChange the Switch Change Input Port Change Output PortSet Configuration Specifications Battery ReplacementIRT Troubleshooting Insert 2 new AA cell batteriesDDC Support Following will be needed RS232 Upgrade of the Front Panel LCD FirmwareNTI Veemux Video Matrix Switch Pinout of RS232 port on Veemux RS232 Connection CablesArrows indicate signal direction Wiring Schematic of Matrix-Y-1 cablePinout for Matrix Y-1 Cable Rack Mounting InstructionsNTI Desktop Size Rack Units Rack Size In. WxDxH SpecificationsSafety Statements TroubleshootingWarranty Information Index