Network Technologies SM-nXm-15V-LCD operation manual Autostatus, Command Definitions Contd

Page 14

NTI VEEMUX VIDEO MATRIX SWITCH

Command Definitions (Cont'd)

 

Command

 

 

Good Response

 

 

Description

 

 

 

 

 

 

 

 

String

 

 

 

 

 

 

 

 

RS SW

 

*<CR>

 

Internal Reset

 

RV SW,00

 

*<CR>string\0<CR>

Read NTI Version String

 

RU SW

 

*<CR>IP,OP<CR>

Read Unit Size

 

EA SW,ip

 

*<CR>

 

Set the IP address, ip is in xxx.xxx.xxx.xxx format,

 

 

 

 

 

 

 

number of digits is minimum 1 and maximum 3 for each field

 

 

 

 

 

 

 

Leading zeroes are accepted

 

EM SW,ip

*<CR>

 

Set the Subnet mask, ip is in xxx.xxx.xxx.xxx format,

 

 

 

 

 

 

 

number of digits is minimum 1 and maximum 3 for each field.

 

 

 

 

 

 

 

Leading zeroes are accepted

 

EG SW,ip

*<CR>

 

Set the default gateway, ip is in xxx.xxx.xxx.xxx format,

 

 

 

 

 

 

 

number of digits is minimum 1 and maximum 3 for each field

 

 

 

 

 

 

 

Leading zeroes are accepted

 

ET SW,timeout

 

*<CR>

 

Set the website timeout; timeout = numeric string of timeout in seconds.

 

 

 

 

 

 

 

Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800

 

 

 

 

 

 

 

0 = no timeout

 

RA SW *

 

<CR>ip<CR>

 

Read the IP address, ip is in xxx.xxx.xxx.xxx format,

 

 

 

 

 

 

 

number of digits is minimum 1 and maximum 3 for each field

 

 

 

 

 

 

 

Leading zeroes are accepted

 

RM SW *

 

<CR>ip<CR>

 

Read the Subnet mask, ip is in xxx.xxx.xxx.xxx format,

 

 

 

 

 

 

 

number of digits is minimum 1 and maximum 3 for each field

 

 

 

 

 

 

 

Leading zeroes are accepted

 

RG SW *

 

<CR>ip<CR>

 

Read the default gateway, ip is in xxx.xxx.xxx.xxx format,

 

 

 

 

 

 

 

number of digits is minimum 1 and maximum 3 for each field

 

 

 

 

 

 

 

Leading zeroes are accepted

 

RT SW *

 

<CR>timeout<CR>

 

Read the website timeout; timeout = numeric value in seconds.

 

 

 

 

 

 

 

Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800

 

 

 

 

 

 

 

0 = no timeout

 

 

 

 

 

 

SS SW,00

*<CR>

 

Disable Autostatus feature (see below)

 

SS SW,01

*<CR>

 

Enable Autostatus feature (see below)

 

GO SW,OP

*<CR>go SW,OP,IP<CR>

Read connection of a Output Port to Input Port

 

GM SW,00

*<CR>go SW,OP,IP (all

 

Read connection matrix of all Output ports

 

 

 

 

ports)<CR>

 

 

 

 

Ss SW,OP,DWT

 

*<CR>

 

Set Scan Mode dwell time for specific Output port

 

 

 

 

 

 

 

DWT values: 000-255 000= scan disabled See page 8 for more info.

 

Gs SW,OP

 

*<CR>

 

Read scan mode dwell time setting for an Output port

 

 

 

 

DWT<CR>

 

DWT values: 000-255 000= scan is disabled for the port

 

Sa SW,OP

*<CR>

Set scan list of individual output to all inputs

 

Sc SW,OP

*<CR>

Clear scan list of individual output

 

S+ SW,OP,IP

*<CR>

Add individual input to Scan List of output

 

S- SW,OP,IP

*<CR>

Remove individual input from Scan List of output

 

Sx SW,OP

*<CR>oooxoxxxooooxxx<

 

Inspect the Scan List of individual output (o=skip x=don't skip)

 

 

 

 

CR>

 

 

 

If the first field is not a known command (as listed above) or SW field is different from the serial address programmed in the switch memory, the command will be ignored. If the SW field corresponds to the unit address, but the syntax is wrong after this field, the switch will answer with a bad response ?<CR>.

Autostatus

When Autostatus is enabled, any output-to-input connection change in the VEEMUX will cause an Autostatus message to be sent via RS232 to the administrator. The format of the message would be "pc SW,OP:IP<CR>"

Example of an Autostatus message:

pc 01,01:04<CR>

which means "At the switch with unit address 01, the output (01) has changed connection to input 04."

Notes: Message to the administrator will be delayed by any RS232 traffic being received by the switch from the administrator.

Autostatus must be disabled before using SerTest or the Matrix Switcher's Control Program (below).

By default, Autostatus is disabled and must be manually enabled. Autostatus is also disabled any time the power to the VEEMUX is interrupted.

10

Image 14
Contents SM-nXm-15V-LCD Trademark Table of Contents Table of Figures Supported Web Browsers IntroductionBasic Operation CompatibiltyCables Default User Name and PasswordsMaterials Materials Supplied with this kitFront View of SM-8X8-15V-LCD Features and FunctionsPower ON/OFF switch Installation Connect the Sources and MonitorsConnect to the Ethernet 9D-male RS232 connectorConnect RS232 Power Up LED MatrixEscape back to the main display Used to enter numbers. # Control OptionsFront Panel LCD with Keypad Control Output user number can be enteredRemote Connection Scan ModeRS232 Control Unit Address Command ProtocolBaud Rate RS232 Matrix-Y-1 CPU Serial PortCommand Definitions Contd AutostatusMatrix Operations SerTest- RS232 Interface Test ProgramMain Options Setup Options Ethernet OperationsTelnet Interface Command Reply DescriptionEthernet Control Telnet 192.168.1.30Enter the Password Web InterfaceVideo Switch Web interface SwitchSetup Pages Web interface SetupWeb interface Serial Setup Video Input NamesScan Mode Output NamesUpdate Firmware Web interface Update FirmwareHelp Change PasswordUpdate Web Server Logout Web interface LogoutDevice Discovery Tool Device Discovery ToolKeypad Features And FunctionsInfrared Control LCD DisplayPower on with SYS, in or OUT keys Power on with 2 key How To Use The IRTChange the Switch Change Output Port Change Input PortSet Configuration IRT Troubleshooting Battery ReplacementSpecifications Insert 2 new AA cell batteriesDDC Support RS232 Upgrade of the Front Panel LCD Firmware Following will be neededNTI Veemux Video Matrix Switch RS232 Connection Cables Pinout of RS232 port on VeemuxPinout for Matrix Y-1 Cable Wiring Schematic of Matrix-Y-1 cableArrows indicate signal direction Rack Mounting InstructionsSpecifications NTI Desktop Size Rack Units Rack Size In. WxDxHWarranty Information TroubleshootingSafety Statements Index