Paradyne Hotwire 5446 installation instructions Troubleshooting, LED Symptom Action

Page 14

Troubleshooting

LED Symptom

Action

 

 

All LEDs are on.

If the LEDs remain on after ten minutes, the RTU is not

 

functional. Contact the NSP.

 

 

ALM LED remains

The power-on self-test may have failed. Unplug the unit and

on.

reapply power. If the alarm light is still on, contact the NSP.

 

 

ALM and TST

Firmware download may be in progress. If firmware download

LEDs are blinking.

is not in progress or the LEDs remain on after ten minutes,

 

contact the NSP.

 

 

DSL LED is off.

Verify that the DSL cable is securely installed on both ends.

 

If the problem continues, contact the NSP.

 

 

DSL LED continues

The RTU is attempting to establish the DSL link or adjusting the

to blink after the

rate of the DSL line due to line conditions. If the DSL LED

power-on self-test.

continues to blink for more than ten minutes, contact the NSP.

 

 

DSL LED is on and

The DSL link has been established but there is no data

there is no data

transmission. Verify the Ethernet connection. If the problem

transmission.

persists, contact the NSP.

 

 

DSL and Ethernet

Verify that your IP address, subnet mask, and default gateway

LEDs are on and

have been entered correctly in the end-user system.

there is no data

 

From the end-user system, use the PC PING utility to ping the

transmission.

5446 RTU's IP address.

 

 

 

 

If no response to the ping, use the PC ARP (Address

 

Resolution Protocol) utility to verify the IP address and physical

 

address (MAC address) from the end-user system to the 5446

 

RTU. If the problem continues, contact the NSP.

 

 

Ethernet LED is off.

Verify that the Ethernet 10BaseT cable is securely installed at

 

both ends, and at least one PC is connected and powered on.

 

 

 

Verify that the correct straight-through or crossover cable is

 

installed. Refer to Installing the Hotwire 5446 RTU, page 8.

 

 

PWR LED is off.

Check that the power cord is securely installed on both ends.

 

 

 

If no LEDs are on, the power supply may be defective. Test the

 

outlet to verify power. If the problem persists, contact the NSP.

 

 

 

If other LEDs are on, the PWR LED may be burned out. Unplug

 

the unit and reapply power; watch all the LEDs during the

 

power-on self-test to verify that the PWR LED is functioning.

 

 

TST LED is on.

A test initiated by the NSP may be active. Wait five minutes. If

 

the TST LED does not go off, contact the NSP.

 

 

14

Image 14
Contents Document Number Document Title Wiring and Cables NeededBefore You Begin DSL Access with a Hotwire 5030 or 5038 Pots Splitter What Does the Hotwire 5446 RTU Do?Package Checklist Customer Premises CP DSL Access with a Hotwire 5038 Distributed Pots SplitterNetwork Service Provider DSL Access without a Pots Splitter Punchdown Block Installing the DSL Access WiringProcedure Telephone Network Interface Device NID DSL/POTSRJ11 Wall Jack Pots Splitter Installing the Hotwire 5446 RTUHotwire RTU Ethernet Line Digital Subscriber Line green Ethernet Link green Power-OnAlarm red Optional RTU Wall Placement RTU Hardware Template Status LEDs Condition StatusTroubleshooting LED Symptom ActionHotwire 5446 RTU Next Hop Router Support Example using TCP/IP Network Settings with Windows Hotwire 5446 RTU IP SetupNetwork Service Provider Example Pin # Function Cables & ConnectorsIncreasing the Number of End-User Systems Pin Ethernet Crossover Cable Function Pin # Pin # Function Pin Straight-Through ConnectionEthernet Cable Hotwire 5446 RTU Technical Specifications SpecificationImportant Safety Instructions Declaration of Conformity JapanCE Marking Canada EMI WarningsTrademarks Warranty, Sales, Service, and Training InformationDocument Feedback