Quatech SSP-200, SSP-300 user manual R option is not used

Page 14

The SSP-200/300 Enabler does not support automatic configuration of adapters upon insertion, more commonly referred to as "Hot Swapping". This means the adapter must be installed in one of the system's PCMCIA sockets before executing SSP231EN.EXE. If more than one adapter is installed in a system, the Enabler must be executed separately for each adapter. Furthermore, SSP231EN.EXE should be executed to release the resources used by the adapter before it is removed from the PCMCIA socket. Since PCMCIA adapters do not retain their configuration after removal, any adapter that is removed from the system must be reconfigured with the Enabler after re-inserting it into a PCMCIA socket.

IMPORTANT: The Enabler requires a region of high DOS memory when configuring a SSP-200/300. This region is 1000H bytes (4KB) long and by default begins at address D0000H (the default address may be changed using the "W" option). If a memory manager such as EMM386, QEMM, or 386Max is installed on the system, this region of DOS memory must be excluded from the memory manager's control. Consult the documentation provided with the memory manager software for instructions on how to exclude this memory region.

2.2.1 Command Line Options

To configure a SSP-200/300 in the system, the Enabler requires one command line argument from the user to determine the configuration of the card. This argument must be enclosed in parenthesis and within the argument, any or all of the following parameters may be specified using a comma (no spaces) to separate each parameter:

Ssocket specifies which PCMCIA socket the SSP-200/300 must be inserted into for this configuration argument to be used. socket must be in the range 0 - 15. This option is required if the 'R' option is not used.

Baddress

specifies the base I/O address of the SSP-200/300 in hexadecimal. This

 

address must reside on an even 8-byte boundary. This option is required if

 

the 'R' option is not used.

Iirq

specifies the interrupt level (IRQ) of the SSP-200/300 in decimal. irq must be

 

one of the following values: 3, 4, 5, 7, 9, 10, 11, 12, 14, 15, or 0 if no IRQ is

 

desired. This option is required if the 'R' option is not used.

2-9

SSP-200/300 (Rev. I and later) User's Manual

Image 14
Contents SSP-200/300 Warranty Information SSP-200/300Declaration of Conformity Standards to whichTable of Contents Introduction This page intentionally left blank DOS/Windows Client Driver Installation SSP-200/300 Client Driver for DOSCommand Line Options BaddressDevice = C\SSP-200\ SSP231CL.SYS Page Common Problems Generic Client DriversOlder Versions of Card and Socket Services SSP-200/300 Enabler for DOSMultiple Configuration Attempts Available ResourcesR option is not used Page Page Socket Numbers Card and Socket Services SoftwareMemory Range Exclusion Page Windows 95/98/Millennium ME Installing a SSP-200/300 Under Windows 95/98/MESSP-200/300 Resource Settings in Windows 95/98/ME Start the Windows 95/98/ME Device Manager 1Viewing Resource Settings with Device Manager2Changing Resource Settings with Device Manager PC CardISR Auxout Base I/O Address Resource Modification Not Allowed Frequently Asked QuestionsBasic Configuration List Not Available This page intentionally left blank Installing a SSP-200/300 Under Windows WindowsDouble click ‘Serial Port Adapters’ Double click ‘Drivers’ Page SSP-200/300 Resource Settings in Windows ManagerLPT Viewing Resource Settings with Device Manager Changing Resource Settings with Device Manager Page Data Rate Multiplier Page Page Basic Auxiliary Range RS-422/485 Clock Scratch 0012 Loopback Any RTS Controlled Auxout Installing SSP-200/300 Windows NTPage Page Page Auxiliary Channel RTS-CTS Handshaking Auxiliary Channel ConfigurationHardware Information Auxiliary Channel Handshaking Disabled Half Duplex Operation OptionsPage Termination Resistors Recommended Termination Resistor ValuesThis page intentionally left blank External Connections SSP-200/300 Adapter CableThis page intentionally left blank Specifications SSP-200/300