Quatech SSP-300 user manual SSP-200/300 Client Driver for DOS, Client Driver Installation

Page 8

2.1 SSP-200/300 Client Driver for DOS

In order to use the SSP-200/300 Client Driver, the system must be configured with Card and Socket Services software. Card and Socket Services software is not provided with the SSP-200/300 but is available from Quatech.

IMPORTANT:

Some versions of Card and Socket Services dated before 1993 do not support general purpose I/O cards. If after careful installation of the Client Driver the adapter does not configure or operate properly, an updated version of Card and Socket Services may be required.

2.1.1 Client Driver Installation

The following procedure is used to install the SSP-200/300Client Driver:

1.Copy the Client Driver from the SSP-200/300 distribution diskette onto the system's hard drive.

2.Using an ASCII text editor, open the system's CONFIG.SYS file located in the root directory of the boot drive.

3.Locate the line(s) in the CONFIG.SYS file where the Card and Socket Services software is installed.

4.AFTER the line(s) installing the Card and Socket Services software, add the

following line to the CONFIG.SYS file:

DEVICE

=

drive:\path\

SSP231CL.SYS options

where

options are the SSP-200/300 Client

Driver command line options discussed on the following pages.

 

5.Save the CONFIG.SYS file and exit the text editor.

6.Insert the SSP-200/300 into one of the system's PCMCIA slots.

NOTE: Since the SSP-200/300 Client Driver supports "Hot Swapping", it is not necessary to have the SSP-200/300 installed when booting the system. By inserting the card before booting, however, the Client Driver will report the adapter configuration during the boot process thereby verifying the changes made to the CONFIG.SYS.

7.Reboot the system and note the message displayed when the SSP-200/300 Client Driver is loaded. If the Client Driver reports an "invalid command line option", correct the entry in the CONFIG.SYS file and reboot the system again. If the Client Driver reports "Card and Socket Services not found", a

2-3

SSP-200/300 (Rev. I and later) User's Manual

Image 8
Contents SSP-200/300 Warranty Information SSP-200/300Declaration of Conformity Standards to whichTable of Contents Introduction This page intentionally left blank DOS/Windows Client Driver Installation SSP-200/300 Client Driver for DOSCommand Line Options BaddressDevice = C\SSP-200\ SSP231CL.SYS Page Common Problems Generic Client DriversSSP-200/300 Enabler for DOS Multiple Configuration AttemptsOlder Versions of Card and Socket Services Available ResourcesR option is not used Page Page Socket Numbers Card and Socket Services SoftwareMemory Range Exclusion Page Windows 95/98/Millennium ME Installing a SSP-200/300 Under Windows 95/98/MESSP-200/300 Resource Settings in Windows 95/98/ME 1Viewing Resource Settings with Device Manager 2Changing Resource Settings with Device ManagerStart the Windows 95/98/ME Device Manager PC CardISR Auxout Base I/O Address Resource Modification Not Allowed Frequently Asked QuestionsBasic Configuration List Not Available This page intentionally left blank Installing a SSP-200/300 Under Windows WindowsDouble click ‘Serial Port Adapters’ Double click ‘Drivers’ Page SSP-200/300 Resource Settings in Windows ManagerLPT Viewing Resource Settings with Device Manager Changing Resource Settings with Device Manager Page Data Rate Multiplier Page Page Basic Auxiliary Range RS-422/485 Clock Scratch 0012 Loopback Any RTS Controlled Auxout Installing SSP-200/300 Windows NTPage Page Page Auxiliary Channel RTS-CTS Handshaking Auxiliary Channel ConfigurationHardware Information Auxiliary Channel Handshaking Disabled Half Duplex Operation OptionsPage Termination Resistors Recommended Termination Resistor ValuesThis page intentionally left blank External Connections SSP-200/300 Adapter CableThis page intentionally left blank Specifications SSP-200/300