Quatech RS-422 Force High-Speed Uart Clock X2 or X4, J4-J5, Enable scratchpad registers

Page 11

J2

J4

J5

SPAD

X4

X2

Figure 4 --- Enable scratchpad registers

2.4.2 Force High-Speed UART Clock (X2 or X4, J4-J5)

These jumpers force an increase of the UART input clock frequency by a factor of two, four, or eight. This feature can allow legacy software to use baud rates above 115,200 bits per second. It is also useful if the serial port device driver does not directly support setting the higher baud rates through the Options Register (see page 10).

If one of these jumpers is applied, it overrides any value written to the Options Register to set the clock multiplier by software. The effective baud rate will be either two or four times the value for which the UART itself is programmed.

The factory default is none of these jumpers applied, which allows for software control of the clock multiplier via the Options Register. The Options Register powerup default is for a standard times-1 clock of 1.8432 MHz for compatibility with standard serial ports.

Figure 5 --- Clock multiplier jumper options

J2

J4

J5

SPAD

X4

X2

factory default

6

DSCLP/SSCLP-200/300 User's Manual

Image 11
Contents DSCLP-200/300 Page Serial Number Declaration of Conformity Table of Contents General Information RS-422 or RS-485 Signal Line Termination Hardware ConfigurationFull-duplex/Half-duplex Operation Signal ConnectionsRCLK0SEL, RCLK1SEL J13 1 CTS0SEL, CTS1SEL J10,172 AUX0SEL1,0, AUX1SEL1,0 J12,11,19,18 Clock Rate and Optional Registers Enable Scratchpad Register SPAD, J24 TGL0SEL1,0, TGL1SEL1,0 J15,14,22,21 RXEN0SEL, RXEN1SEL J16Force High-Speed Uart Clock X2 or X4, J4-J5 Enable scratchpad registersX4 mode Jumper/connector locations Hardware InstallationBase Address and Interrupt Level IRQ Address Map and Special RegistersInterrupt Status Register Enabling the Special RegistersQuatech Modem Control Register Quatech Modem Control RegisterEnhanced Serial Adapter Identification Options RegisterRR1 RR0 Clock Rate MultiplierWindows Millennium Windows ConfigurationsWindows Windows Windows Using the New Hardware Found Wizard Viewing Resources with Device Manager Page Page Page DOS and other operating systems Other Operating SystemsWindows NT OS/2QTPCI.EXE Basic Mode display QTPCI.EXE Expert Mode display Jumper/Channel correspondence External ConnectionsRclk RTS/CTS HandshakeAUXIN/AUXOUT Loopback XclkHalf-Duplex/Full-Duplex Selection Half- or full-duplex selection RS-422/485 Line termination resistance values Termination ResistorsRS-422/485 Peripheral Connection DSCLP-200/300 connector definitionsINTA# PCI Resource MapWith 64-byte FIFOs optional SpecificationsComputer will not boot up TroubleshootingDSCLP-200/300 Revision December