5 ADDRESSING
The MPA-200 occupies a continuous 8 byte block of I/O addresses. For example, if the base address is set to 300H, then the MPA-200 will occupy address locations 300H-307H. The base address of the MPA-200 may be set to any of the first 64 Kbytes (0 - FFFFH) of available I/O address space through the settings of dip switches SW1 and SW2. SW1 allows the user to select the higher address signals A15 - A8. SW2 allows the user to select the lower address signals A7 - A3. The sixth position of SW2 is not used and can be ignored. Figure 2 shows some examples of different base addresses.
Figure 1 Address switch selection examples.
| A15 | A14 | A13 | A12 | A11 | A10 | A9 | A8 |
| ON | | | | | | | |
SW1 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
1 2 3 4 5 6 7 8 | SW2 | 1 2 3 4 5 6 |
Base Address = 3F8H
15 | Quatech Inc., MPA-200/300 Manual |