Quatech RS-422/485, MPA-200/300 user manual DTE / DCE Configuration

Page 31

10 DTE / DCE Configuration

The MPA-200 can be purchased in either Data Terminal Equipment (DTE) or Data Communications Equipment (DCE) configuration. The two configurations share some important features, but have significant differences which need to be mentioned.

Both the DTE and DCE configurations allow the user to enable and disable the driver circuitry on the MPA-200 through the settings of jumper block J7. See the chapter JUMPER BLOCK CONFIGURATIONS on page 11 for further informa- tion on the configuration of this jumper block. They both also have the ability to receive data and receive clock (RCLK) on channel B of the SCC. This allows the user to transmit and receive on two different channels.

The differences between the MPA-200’s DTE configuration and its DCE configu- ration include signal definitions, control signals, clocking options and testing. The following sections describe each configuration individually and in detail.

25

Quatech Inc., MPA-200/300 Manual

Image 31
Contents QUATECH, INC MPA-200/300Page Warranty Information Page Compliances Electromagnetic Emissions Table of Contents Quatech Inc., MPA-200/300 Manual Introduction MPA-200 board drawing IRQ DMA/DRQ Hardware InstallationSCC General Information Accessing the registers RR3 RR0RR1 RR2WR3 WR0WR1 WR2Baud Rate Generator Programming SCC Data Encoding Methods IRQ3 IRQ4 IRQ5 IRQ6 IRQ7 Jumper Block ConfigurationsJ4 Interrupt Configuration J5 & J6 Interrupt Level SelectionJ10 Transmit DMA Channel Selection IRQ10 IRQ11 IRQ12 IRQ14 IRQ15J7 Line Driver Control Selection J11 Receive DMA Channel SelectionSynca Rlen OUT J8 Synca to Rlen controlBase Address = 3F8H AddressingPage Interrupts Direct Memory Access Page Reqa Configuration Register D0 -TXSRC, Transmit DMA Source D1 -RXSRC, Receive DMA SourceTM ST Llen Rlen Rcken Tcken Rxden Txden Communications RegisterD0 -TRANSMITTER Enable D1 -RECEIVER EnableDTE / DCE Configuration Rrclk Rtclk Trxca Tclk Ttclk DTE ConfigurationDCE Configuration DCE Clock Configuration External Connections CTS Ctsa +DSR Dcda DTR DTR/REQA DSR Dcda +RRCLK Trxc Test ModeTest Mode Null-Modem Cables Connector Notation +RXD,-RXD Circuit AB Signal Ground Connector Notation DgndCircuit CC Data SET Ready DSR Connector Notation +DSR,-DSR Connector Notation +TXD,-TXDCircuit CB Clear to Send CTS Connector Notation +CTS,-CTS Connector Notation +RTCLK,-RTCLKConnector Notation +RRCLK,-RRCLK Circuit CA Request to Send RTS Connector Notation +RTS,-RTSCircuit LL Local Loopback LL Connector Notation Llbk Circuit CD DTE Ready DTR Connector Notation +DTR,-DTRCircuit RL Remote Loopback RL Connector Notation Rlbk Circuit TM Test Mode TM Connector Notation Test Mode Specifications MPA-200/300 Version March