4.4.2 Clock Rate Multiplier

A standard RS-232 serial port operates at a clock speed of 1.8432 MHz. In order to achieve higher data rates, Quatech Enhanced Serial Adapters can operate at two times, four times or even eight times this standard clock speed. This is controlled by the clock rate multiplier bits in the Options Register.

Software can determine the UART clock frequency by reading the clock rate multiplier bits RR1 and RR0 in the Options Register as shown in Figure 11. RR1 and RR0 can be set by writing to the Options Register if the X2 and X4 jumpers (J4-J5) are all removed. This card has the 16550 UART. If one of these jumpers is applied, the RR1 and RR0 bits are forced to the appropriate value. Reading the Options Register will always return the clock rate multiplier at which the board is operating.

RR1

RR0

Clock Rate

UART Clock

Maximum Data

Multiplier

Frequency

Rate

 

 

0

0

X1

1.8432 MHz

115.2 kbaud

(default)

 

 

 

 

0

1

X2

3.6864 MHz

230.4 kbaud

1

0

X4

7.3728 MHz

460.8 kbaud

1

1

X8*

14.7456 MHz

921.6 kbaud

Figure 11 --- Rate Register bit definition

*x8 mode is only accessable via sotware control

At powerup and reset, the Options Register is initialized to 0. The

DSCLP-100 will thus powerup in the x1 mode with software control of the clock rate multiplier enabled as long as the X2 or X4 jumpers are not installed.

Software can control high baud rates through a combination of changing the clock rate multiplier and the UART baud rate divisor. For example, a baud rate of 230.4 kbps could be achieved by setting the clock rate multiplier to X2 mode (or by applying the X2 jumper) and setting a software application for 115.2 kbps.

13

DSCLP/SSCLP-100 User's Manual

Image 13
Contents DSCLP/SSCLP-100 Warranty Information Page Declaration of Conformity Address Map and Special Registers Windows ConfigurationsBase Address and Interrupt Level IRQ Enhanced Serial Adapter IdentificationGeneral Information Factory Default Configuration Hardware ConfigurationEnable Scratchpad Register SPAD, J2 Clock multiplier jumper options Jumper/connector locations Hardware InstallationPort Address Range Interrupt Status Register Enabling the Special RegistersBit Name Description Options RegisterRR1 RR0 Clock Rate MultiplierWindows Millennium Windows Windows Windows Using the New Hardware Found Wizard Page Viewing Resources with Device Manager Page Page Dual-Port RS-232 Serial Adapter Page Page For legacy applicattions which cannot Page Page Windows NT Other Operating SystemsOS/2 DOS and other operating systemsQTPCI.EXE QTPCI.EXE Expert Mode display External Connections RS-232 Port Signal SSCLP-100 PCI Resource MapICL3245CA SpecificationsPage Computer will not boot up TroubleshootingDSCLP/SSCLP-100