Quatech DSCLP/SSCLP-100 user manual

Page 25

 

 

Data Rate Multiplier

 

 

Clock Mode

Max bps

Description

 

 

 

 

Auto clock mode enables applications to

 

 

 

 

request any baud rate up to 921,600.

 

 

Auto

921,600

The hardware drivers will select the

 

 

 

 

correct clock multiplier based on the

 

 

 

 

baud rate requested

 

 

 

 

The X1 clock mode mimics a standard

 

 

 

 

COM port. The hardware drivers lock

 

 

X1

115,200

the clock to the standard rate. The port

 

 

 

 

will run at the baud rate requested by

 

 

 

 

the application.

 

 

 

 

The X2 clock mode locks the ports

 

 

 

 

hardware clock at double the standard

 

 

X2

230,400

rate. The baud rate the port runs at will

 

 

 

 

always be double the rate requested by

 

 

 

 

the applications. This mode is useful

 

25

 

 

DSCLP/SSCLP-100 User's Manual

Image 25
Contents DSCLP/SSCLP-100 Warranty Information Page Declaration of Conformity Address Map and Special Registers Windows ConfigurationsBase Address and Interrupt Level IRQ Enhanced Serial Adapter IdentificationGeneral Information Factory Default Configuration Hardware ConfigurationEnable Scratchpad Register SPAD, J2 Clock multiplier jumper options Jumper/connector locations Hardware InstallationPort Address Range Interrupt Status Register Enabling the Special RegistersBit Name Description Options RegisterRR1 RR0 Clock Rate MultiplierWindows Millennium Windows Windows Windows Using the New Hardware Found Wizard Page Viewing Resources with Device Manager Page Page Dual-Port RS-232 Serial Adapter Page Page For legacy applicattions which cannot Page Page Windows NT Other Operating SystemsOS/2 DOS and other operating systemsQTPCI.EXE QTPCI.EXE Expert Mode display External Connections RS-232 Port Signal SSCLP-100 PCI Resource MapICL3245CA SpecificationsPage Computer will not boot up TroubleshootingDSCLP/SSCLP-100