Quatech DSCLP/SSCLP-100 user manual Using the New Hardware Found Wizard

Page 18

5.5 Using the "New Hardware Found" Wizard

The following instructions provide step-by-step instructions on installing the DSCLP-100 in Windows 95 using the "New Hardware Found" wizard.

1.After booting the computer with a newly-installed DSCLP-100, the "New Hardware Found" dialog box will appear. If you have never installed a Quatech PCI communications adapter before, the dialog box may simply indicate that it has found a "PCI Card."

2.Select the radio button for "Driver from disk provided by hardware manufacturer." Click the "OK" button to continue.

3.An "Install From Disk" dialog box should pop up. Insert the disk with the Quatech INF files on it, select the correct drive letter, and click the "OK" button. Windows 95 automatically browses the root directory for an INF file that defines configurations for Multi-function Adapters. If no INF files are found, click the "Browse" button and search the Win95 sub directory on the installation disk. You are not required to select the file name. After finding the directory containing the INF files, Windows 95 will choose the correct file.

4.The "New Hardware Found" dialog box will appear again, this time for an "Unknown Device."

5.Again select the radio button for "Driver from disk provided by hardware manufacturer." Click the "OK" button to continue.

6.Another "Install From Disk" dialog box will pop up. The path should already be pointing to the Quatech disk. Click the "OK" button to continue.

7.You should now see the "Copying Files" dialog box as Windows 95 copies the driver files from the disk.

8.The installation utility will ask for your Windows 95 installation disks. Serial communication ports require two drivers supplied by Microsoft to function: SERIAL.VXD and SERIALUI.DLL. Insert the disk or CD and click "OK".

18

DSCLP/SSCLP-100 User's Manual

Image 18
Contents DSCLP/SSCLP-100 Warranty Information Page Declaration of Conformity Base Address and Interrupt Level IRQ Windows ConfigurationsAddress Map and Special Registers Enhanced Serial Adapter IdentificationGeneral Information Hardware Configuration Factory Default ConfigurationEnable Scratchpad Register SPAD, J2 Clock multiplier jumper options Hardware Installation Jumper/connector locationsPort Address Range Enabling the Special Registers Interrupt Status RegisterOptions Register Bit Name DescriptionClock Rate Multiplier RR1 RR0Windows Millennium Windows Windows Windows Using the New Hardware Found Wizard Page Viewing Resources with Device Manager Page Page Dual-Port RS-232 Serial Adapter Page Page For legacy applicattions which cannot Page Page OS/2 Other Operating SystemsWindows NT DOS and other operating systemsQTPCI.EXE QTPCI.EXE Expert Mode display External Connections RS-232 Port Signal PCI Resource Map SSCLP-100Specifications ICL3245CAPage Troubleshooting Computer will not boot upDSCLP/SSCLP-100