2 • Hardware installation

 

 

Figure 6. Ethernet RJ-45 pin and signal definitions for T-DAC

Connecting the 10/100Base-T Ethernet port to an Ethernet-capable workstation or PC

The 10/100Base-T Ethernet port can connect to a single Ethernet-capable workstation or PC by means of a cross over cable. Refer to figure 7 to assemble a cross-connect cable that will connect between the NIC Ether- net port in the workstation and the T-DAC 10/100Base-T Ethernet port.

Figure 7. Cross-over RJ-45-to-RJ-45 Ethernet cable diagram

Connecting the EIA-561 RS-232 configuration port (DCE configured)

Install the supplied RJ-45-to-RJ-45 cable with the DB9-RJ45 adapter between the T-DAC RS-232 port (see figure 5 on page 22) and an open serial port on your computer. If you need to assemble your own cable, refer to the pinout diagram in figure 8.

Figure 8. DB-9-to-RJ-45 cable diagram

Cable installation

23

Image 23
Contents T1/E1 TDM-Digital Access Concentrator T-DAC Patton Electronics Company, Inc Summary Table of Contents Contents Operation and shutdown Compliance information List of Figures Model 2960 RAS Getting Started Guide List of Tables Structure About this guideAudience Safety when working with electricity PrecautionsMouse conventions Typographical conventions used in this documentGeneral conventions Introduction Chapter contentsModel 2616RC T-DAC Model 2616RC T1/E1 T-DAC overviewWAN Hardware overviewManagement services Power systemTemperature Physical dimensionsMIB LED LED displayHardware installation Unpacking the Model 2616RC T-DAC DAC blades installationIntroduction Alignment/ESD pin and card handle Connecting the Ethernet ports Cable installationDB-9-to-RJ-45 cable diagram Pin Scsi to 8 RJ-45 connectors cable Connecting the T1/E1 WAN portsWAN cable‘s 68-pin Scsi connector SCSI-to-open-end WAN cable Pin Scsi to open end cableWAN cable’s 68 non-terminated twisted-pairs Punch-down block wiring Installing the WAN cable to a punch-down blockPin Scsi to 64-pin female Telco 10-3096TM68/64-6 Pin Scsi to open end, 6 foot cable 10-3096TM68-6-ObsoleteCompleting the hardware installation Configuring the T-DAC for operation Configuration prerequisites Connecting the DB9-RJ45 adapter with the included cable Initial configuration through the RS-232 control portConnection Description window Setting up the HyperTerminal or similar program sessionConfigure your COM port settings as shown in , then click OK Login window Ethernet configuration window Using a browser to complete Model 2616RC configurationHome page overview Displaying the T-DAC 2616RC web administration pagesHome page window panes Flash Configuring the default gatewayExample Configuring the system clocking parametersSystem Clocking Configuration page, example For Clock Reference select secondary2 or slave3 DS0 Mapping Overview window Configuring the DS0 mappingExamples for configuring static connections Accessing the Line Interface Settings Configuring line settings and signaling for E1T1/E1 Link Activity Ports 1 4 Configuring the E1 line interface settingsFrom the Line Build Out pull-down menu select e1pulse1 E1 Alarms Present indicator Configuring line settings and signaling for T1Line Type pull-down menu with dsx1ESF2 selected Configuring the T1 line settingsFrom the Line Build Out pull-down menu select t1pulse0dB1 Alarm Card Information window Enabling/disabling the alarm cardBacking up your configuration parameters Saving your configurationIMPORT/EXPORT Backing up the configuration store in flash memory Completing the installation Configuring the T-DAC for operation Operation and shutdown De-activating the Model 2616RC Activating the Model 2616RCTroubleshooting and maintenance Cited in De-activating the Model 2616RC on Power Fault analysisSystem DSX1 payload loop dsx1PayloadLoop T1/E1 port test modesLine Loop DSX1 line loop dsxLineLoopCalibration Periodic maintenanceMaintenance Exporting the current Model 2616RC configurationMaintenance Troubleshooting and maintenance Removing the defective Model 2616RC Importing a saved configuration Installing the replacement Model 2616RCCompleting the installation Contacting Patton for assistance Returns for credit Warranty coverageOut-of-warranty service Contact informationShipping instructions Return for credit policyRMA numbers EMC Appendix a Compliance informationIndustry Canada Notice SafetyCompliance Radio and TV InterferenceAuthorized European Representative FCC Part 68 Acta StatementCE Declaration of Conformity Introduction Not Used Introduction