OnSite Series Getting Started Guide | 3 • Installation Overview |
|
|
Note Take care to load the rack so that it is not top heavy.
Note Do not cover vents that would restrict airflow. Leave a minimum of a
3.Secure the chassis using four
4.Tighten any loose captive installation screws on the expansion slot front panel covers.
Figure 10. Mounting the OS-10 System Chassis in an EIA/TIA 19-Inch Rack
Mounting the Chassis to an ETSI Rack
To install the
1.Install the two L mounting brackets in the orientation shown in Figure 11. Insert and fully tighten the screws to secure the brackets to the chassis (four screws for each bracket). Use a suitable screwdriver for this task.
Note For this rack configuration, the L mounting bracket holes are posi- tioned 50 mm back from the front panel of the
2.Position the chassis in the rack and align the mounting holes in the L bracket with the mounting holes in the equipment rack.
Note The
Note Take care to load the rack so that it is not top heavy.
OnSite System Installation | 30 |