To remove an existing SNMP trap receiver, follow these steps:

1.Select a trap receiver on the SNMP Trap Receivers page.

2.Click on Delete to remove the trap receiver.

At this point, the system removes the trap receiver, and it is no longer displayed in the table.

In addition to supporting the generation of traps to an SNMP-based NMS, the system also sends autonomous messages to all connected OnSight NMSs. The OnSight NMS provides centralized management and control of OS-10 systems in point-to-point, linear, and ring ADM subnetworks.

To display the OnSight NMS servers authorized to manage the OS-10 system, see Figure 19 and follow these steps:

1.Select the SYSTEM folder from the navigation menu.

2.From the expanded SYSTEM folder, select Management Access.

3.From the expanded Management Access folder, select NMS.

On the Authorized NMS Servers page, the table displays the IP addresses of the OnSight NMS servers autho- rized for management connectivity to the system.

To add an OnSight NMS server to the list of authorized servers, see Figure 19 and follow these steps:

1.On the Authorized NMS Servers page, click on Add.

2.In the Add Authorized NMS Server window, type the NMS IP Address and click on Apply.

3.Click on Close to close the window.

Figure 19. Configuring an Authorized OnSight NMS Server

Autonomous Alarm Messages

48

Image 48
Contents Metro-Optical Transport Access Nodes Mailsupport@patton.com Summary Table of Contents Table of Contents System Management Access Terms and Acronyms List of Figures List of Tables About this guide AudiencePrecautions StructureTypographical conventions used in this document General conventionsMouse conventions Safety when using electricity Power CableOptical Safety Fiber-Optic Safety PrecautionsElectrostatic Discharge Damage Fiber-Optic PortsChapter contents Product OverviewIntroduction OnSite PlatformsSDH Trunks OS1052 Base System Application Overview OS1052 Application Typical OS1052 applicationOS1052 Map + Modules OS1063 Application Typical OS1063 applicationOS1063 Map + Modules Installation Overview Unpacking and Inspection Site PreparationSite Environment Planning Your SiteSite Requirements Operating Environment Requirements Power Supply Requirements Mechanical Recommendations for the Rack Protective Grounding for the Rack and ChassisSpace Requirements for the Rack Securing the RackTools and Equipment for Installation and Maintenance OnSite System InstallationMounting the Chassis to an EIA/TIA 19-Inch Rack Mounting the Chassis to an Etsi Rack Mounting the OS-10 System Chassis in an EIA/TIA 19-Inch RackMounting the OS-10 System in an Etsi 300-mm Rack Mounting the Chassis on the Wall Mounting the OS-10 System Chassis on a WallInstalling the Chassis Ground Connection Connecting Power to the OS-10 SystemConnecting AC Power to the OS-10 System Powering On the OS-10 System with AC Power Wiring the OS-10 System for DC Power Installation Overview Checking the OS-10 System Installation System Management Access General Overview Ethernet LAN Management Port Detail of the Management PortsProvides the pin assignments for the RJ-45 connector Serial Management PortGaining Access to the System Access through the Serial PortAccess through the Ethernet LAN Management Port Web-Based Management Interface Launching the GUI ApplicationGUI Frames Provides Autonomous Alarm Messages Configuring an Snmp Trap ReceiverConfiguring an Authorized OnSight NMS Server Engineering Orderwire EOW Location of EOW port AUX 1 on OS-10 Series ChassisSystem Management Access Configuring the Engineering Orderwire EOW Function System Management Access Contacting Patton for assistance Warranty coverage Contact informationReturn for credit policy RMA numbersAppendix a Compliance information Safety ComplianceRadio and TV Interference FCC Part 68 Acta StatementDeclaration of Conformity Authorized European RepresentativeAppendix B Specifications Model OS1052 Dimensions WeightPower OperationsModel OS1063 Operations Appendix C Terms and Acronyms Abbreviations Abbreviation MeaningLcas TDM