Rackmount Solutions VA 2000, VA 3000, VA 700, VA 10000 Active Tower and Rackmount Specifications

Page 26

Chapter 10 Active Tower and Rackmount Specifications

Table 5. Chloride Active UPS North America

UPS Model

Active 700

 

Active 1000

 

Active 2000

 

Active 3000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rating

700 VA

 

1 kVA

 

2 kVA

 

3 kVA

 

 

 

 

 

 

 

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

 

120 VAC single-phase

 

 

 

 

 

 

Voltage range A

 

 

80 - 138 VAC

 

 

 

 

 

 

Frequency

 

 

50/60Hz ± 0.5%

 

 

 

 

 

 

Power factor (lambda)

 

>0.95

 

 

 

 

 

 

 

 

 

 

Battery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Integrated battery type

 

Lead-calcium, maintenance-free

 

 

 

 

 

 

 

 

Battery voltage (V)

24

 

36

 

96

 

96

 

 

 

 

 

 

 

 

Runtimes (min.)

10/5

 

15/6

 

18/7

 

10/5

(half load/full load)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Runtimes (min.),1 battery cabinet

NA

 

70/30

 

100/30

 

60/30

(half load/full load)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Runtimes (min.), 2 battery cabinets

NA

 

130/60

 

200/80

 

120/50

(half load/full load)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

100/110/120 VAC, single-phase

 

 

 

 

 

 

Voltage tolerance

 

± 3%

 

 

 

 

 

 

 

Frequency with mains control

 

 

see input frequency

 

 

 

 

 

 

Frequency with internal control

 

 

50/60 Hz, ±0. 5%

 

 

 

 

 

 

Distortion factor (linear/non-linear load)

 

 

max. 4%/max. 7%

 

 

 

 

 

 

 

 

Permissible crest factor

 

 

 

3

 

 

 

 

Overload capability

130% for 1.5 sec., 110% for 10 sec.

 

 

output short-circuit proof

 

 

 

 

 

 

 

 

 

 

 

 

 

Common Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical safety

 

 

UL1778

 

 

 

 

 

 

Radio interference level

 

 

FCC Part 15 Class A

 

 

 

Interference immunity

IEC 801-2,level 4 / IEC 801-3,level 3;

IEC 801-4,level 4 / IEC 801-5,level 2)

 

 

 

 

 

 

 

 

 

22

Chloride Active and E-Series UPS User Manual

Image 26 Contents
Page Important Safety Instructions FCC ComplianceChloride Introduction Operational Characteristics E-Series Chloride Introduction Technical Support and Service ActiveSafety Notes Registering your Chloride Active UPSPage Display and Operation Elements Active Overload LoadFront Rear Active 700Active 2000 Active 3000 Rear ViewActive Rackmount Series SafetyInstallation and operating notes Type of Battery Packs Maximum Number of Packs Connection of a battery packBattery Cabinets Mechanical AttachmentUnit Rear View and Connections Active 700-19 and Active Active700-19Active 2000-19 and Active Active3000-19Active Installation and Commissioning Model Cabinet Batteries Commissioning of an External Battery CabinetExternal Battery Packs Operational Characteristics Active Ready for Operation Check Self TestNormal Operation, Inverter On Mains Available Battery Operation, Inverter On Mains FailureModes of Operation Bypass Operation, Inverter OFF Overload 140% Front Display Panel During Bypass Operation Overload 140%Description of the Interface Active Standard Interface COM aPin Number Condition Optional Interface COM BInterface COM a INV Shutdown Storage Maintenance ActiveCleaning Problem Possible Cause Action to Take Troubleshooting ActiveTroubleshooting Page Active Tower and Rackmount Specifications Chloride Active UPS North AmericaUPS Model Active Battery extensionSignals Mechanical DataUPS Model Active Connections Mains connections Load connectionActive Rackmount Technical Data for North American Models Operating DataBattery Lifetime Typical lifetime of the batteriesTechnical Support and Service E-Series Registering your Chloride E-Series UPSPage Display and Operation Elements E-Series Switch for at least 1 second. a tone sounds Series E61 and E101 E41 or E61Series E203 E81 or E101Series Installation and Commissioning Installation of the E-Series HardwiredPage Minimum Requirements for E-Series UPS Installation Lbs AwgWiring Diagram for the E101 Commissioning of the E-Series Starting Up the E-SeriesDryers, vacuum cleaners BPE61 Technical data of the connection cable E101 E203Self Test Modes of Operation Bypass Operation, Inverter OFF Overload 140% Description of the Interface E-Series Optional Interface COM B Emergency Power Off EPO Series Models E153X and E203X onlyMaintenance E-Series Troubleshooting E-Series Page Series Specifications Chloride E-Series UPS North AmericaBPE101 Weight lbs 337 894 Dimensions HxWxD in. mm E101XA E203XA E41XA E81 E153XA Connections Optional Power Distribution Units PDU available 4 -10 kVA Optional Power Distribution UnitsChloride Power Protection