Chapter 1 Chloride Introduction

Thank you for selecting this uninterruptible power supply (UPS). Chloride’s Active UPS offers the most reliable protection from the harmful effects of electrical line disturbances for your computing and communications equipment.

1.1 Registering your Chloride Active UPS

To ensure that your Active model and serial number are registered, complete and mail the enclosed postage- paid warranty card.

1.2 Technical Support and Service (Active)

Chloride offers 24-hour technical support. To contact Chloride Technical Services:

Phone: (800) 879-5011

email: usa.service@chloridepower.com.

NOTE: All calls received before 7 a.m. or after 7p.m. Central Standard Time are forwarded to a cell phone. A Chloride Technical Service Representative will return your call within one half hour between 5 p.m. and 10 p.m. Central Standard Time. Except for emergencies, calls received between 10 p.m. and 7 a.m. will be returned during normal business hours.

Please check with Chloride Technical Services before attempting to repair or return any Chloride product. If a Chloride unit needs repair or replacement, Chloride Technical Services issues a Return Material Authorization (RMA) number along with instructions on how to return the unit.

1.3 Safety Notes

WARNING: Read the following information carefully! Disregard of these safety notes may endanger your life and health as well as the functioning of your equipment and the safety of your data.

WARNING: This equipment services power from more than one source. The output receptacles may have voltage even when the unit is unplugged.

UPSs present a different safety issue than most electrical equipment because unplugging the UPS puts it into backup mode. Unplugging the UPS does not remove the electrical charge. To ensure that the UPS is off, push BYPASS (for a minimum of 1 second) before unplugging the UPS from the mains.

CAUTION: Operating this equipment without proper grounding may present a risk of electrical shock.

Do not use AC adaptors with only two conductors to connect the input line cord to the wall socket as this will not connect the earth ground to the equipment.

WARNING: Dangerous voltages are present within this unit! There are no user-serviceable parts inside. Any repairs or modifications by the user may result in out-of-warranty repair charges, unsafe electrical conditions, or violation of electrical code.

This device complies with the relevant safety regulations for uninterruptible power supplies for use in a controlled office environment. If you have any questions, please contact Chloride Technical Service at 1- 800-879-5011.

Chloride Active and E-Series UPS User Manual

1

Image 5 Contents
Page FCC Compliance Important Safety InstructionsChloride Introduction Operational Characteristics E-Series Safety Notes Technical Support and Service ActiveChloride Introduction Registering your Chloride Active UPSPage Overload Load Display and Operation Elements ActiveFront Active 700 RearActive 3000 Rear View Active 2000Active Rackmount Series SafetyInstallation and operating notes Battery Cabinets Connection of a battery packType of Battery Packs Maximum Number of Packs Mechanical AttachmentActive700-19 Unit Rear View and Connections Active 700-19 and ActiveActive3000-19 Active 2000-19 and ActiveActive Installation and Commissioning Model Cabinet Batteries Commissioning of an External Battery CabinetExternal Battery Packs Self Test Operational Characteristics Active Ready for Operation CheckNormal Operation, Inverter On Mains Available Battery Operation, Inverter On Mains FailureModes of Operation Front Display Panel During Bypass Operation Overload 140% Bypass Operation, Inverter OFF Overload 140%Standard Interface COM a Description of the Interface ActivePin Number Condition Optional Interface COM BInterface COM a INV Shutdown Storage Maintenance ActiveCleaning Problem Possible Cause Action to Take Troubleshooting ActiveTroubleshooting Page Chloride Active UPS North America Active Tower and Rackmount SpecificationsSignals Battery extensionUPS Model Active Mechanical DataLoad connection UPS Model Active Connections Mains connectionsOperating Data Active Rackmount Technical Data for North American ModelsTypical lifetime of the batteries Battery LifetimeRegistering your Chloride E-Series UPS Technical Support and Service E-SeriesPage Display and Operation Elements E-Series Switch for at least 1 second. a tone sounds E41 or E61 Series E61 and E101E81 or E101 Series E203Installation of the E-Series Hardwired Series Installation and CommissioningPage Lbs Awg Minimum Requirements for E-Series UPS InstallationWiring Diagram for the E101 Starting Up the E-Series Commissioning of the E-SeriesDryers, vacuum cleaners BPE61 E101 E203 Technical data of the connection cableSelf Test Modes of Operation Bypass Operation, Inverter OFF Overload 140% Description of the Interface E-Series Optional Interface COM B Series Models E153X and E203X only Emergency Power Off EPOMaintenance E-Series Troubleshooting E-Series Page Chloride E-Series UPS North America Series SpecificationsBPE101 Weight lbs 337 894 Dimensions HxWxD in. mm E101XA E203XA E41XA E81 E153XA Connections Optional Power Distribution Units Optional Power Distribution Units PDU available 4 -10 kVAChloride Power Protection