Rackmount Solutions VA 20000, VA 3000, VA 700 BPE101 Weight lbs 337 894 Dimensions HxWxD in. mm

Page 55

Table 12. Chloride E-Series UPS North America

UPS Model

E61XA

E101XA

 

 

 

E203XA

(E41XA*)

(E81*)

 

 

 

(E153XA*)

 

 

 

 

 

 

 

 

 

 

 

 

Interference immunity

IEC 801-2,level 4 / IEC 801-3,level 3

 

IEC 801-4,level 4 / IEC 801-5,level 2

 

 

 

 

 

 

 

 

 

 

Efficiency

> 86%

>90%

 

 

 

>85%

 

 

 

 

 

 

 

 

Cooling

 

Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

Common Data (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Noise level mains operation

< 50 dBa

< 55 dBa

 

 

 

<65 dBa

 

 

 

 

 

 

 

Noise level battery operation

< 55 dBa

<65 dBa

 

 

 

<65 dBa

 

 

 

 

 

Operating temperature

+ 50°F to +105°F (+10°C to + 40°C)

 

recommended +59°F to +89°F

(+15°C to + 32°C)

 

 

 

 

Storage temperature

+5°F to +104°F (-15°C to +40°C)

 

 

 

 

Relative humidity

20% to 90%, non-condensing

 

 

 

 

 

 

max. 10,000 ft. (3,000m),

 

 

Altitude

above 5,000 ft. (1,500m) max ambient temperature = 95°F

 

 

(35 °C)

 

 

 

 

 

 

 

 

 

 

 

 

 

Mechanical Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight - lbs.

347

580

 

 

 

 

787

 

 

 

 

 

 

 

27.8 x 10.6 x 22.5

38 x 13.4 x 25

 

46.5 x 16.5 x 31.5

Dimensions - HxWxD in. (mm)

 

 

(1180 x 420 x

(705 x 270 x 570)

(965 x 340 x 670)

 

 

 

 

800)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery extension

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

BPE61

 

BPE101

 

 

 

 

 

 

 

 

Weight lbs

337

 

 

894

 

 

 

 

 

 

Dimensions - HxWxD in. (mm)

27.8 x 10.6 x 22.5

38 x 15 x 26.4

 

(705 x 270 x 570)

(965 x 380 x 670)

 

 

 

 

 

 

 

 

 

Signals

 

 

 

 

 

 

 

 

 

 

 

 

Visual

LED-indication at the front side

 

 

 

 

 

 

 

 

Audible

 

Acoustical alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

RS232 interface

 

 

 

 

Communications

Alarm contacts +5V...+12V

 

 

Signal input +5V...+12V

 

 

 

 

 

 

 

ethernet

 

 

 

 

 

 

 

 

 

 

 

 

 

Chloride Active and E-Series UPS User Manual

51

Image 55
Contents Page FCC Compliance Important Safety InstructionsChloride Introduction Operational Characteristics E-Series Registering your Chloride Active UPS Technical Support and Service ActiveSafety Notes Chloride IntroductionPage Overload Load Display and Operation Elements ActiveFront Active 700 RearActive 3000 Rear View Active 2000Installation and operating notes SafetyActive Rackmount Series Mechanical Attachment Connection of a battery packBattery Cabinets Type of Battery Packs Maximum Number of PacksActive700-19 Unit Rear View and Connections Active 700-19 and ActiveActive3000-19 Active 2000-19 and ActiveActive Installation and Commissioning External Battery Packs Commissioning of an External Battery CabinetModel Cabinet Batteries Self Test Operational Characteristics Active Ready for Operation CheckModes of Operation Battery Operation, Inverter On Mains FailureNormal Operation, Inverter On Mains Available Front Display Panel During Bypass Operation Overload 140% Bypass Operation, Inverter OFF Overload 140%Standard Interface COM a Description of the Interface ActiveInterface COM a Optional Interface COM BPin Number Condition INV Shutdown Cleaning Maintenance ActiveStorage Troubleshooting Troubleshooting ActiveProblem Possible Cause Action to Take Page Chloride Active UPS North America Active Tower and Rackmount SpecificationsMechanical Data Battery extensionSignals UPS Model ActiveLoad connection UPS Model Active Connections Mains connectionsOperating Data Active Rackmount Technical Data for North American ModelsTypical lifetime of the batteries Battery LifetimeRegistering your Chloride E-Series UPS Technical Support and Service E-SeriesPage Display and Operation Elements E-Series Switch for at least 1 second. a tone sounds E41 or E61 Series E61 and E101E81 or E101 Series E203Installation of the E-Series Hardwired Series Installation and CommissioningPage Lbs Awg Minimum Requirements for E-Series UPS InstallationWiring Diagram for the E101 Starting Up the E-Series Commissioning of the E-SeriesDryers, vacuum cleaners BPE61 E101 E203 Technical data of the connection cableSelf Test Modes of Operation Bypass Operation, Inverter OFF Overload 140% Description of the Interface E-Series Optional Interface COM B Series Models E153X and E203X only Emergency Power Off EPOMaintenance E-Series Troubleshooting E-Series Page Chloride E-Series UPS North America Series SpecificationsBPE101 Weight lbs 337 894 Dimensions HxWxD in. mm E101XA E203XA E41XA E81 E153XA Connections Optional Power Distribution Units Optional Power Distribution Units PDU available 4 -10 kVAChloride Power Protection

VA 2000, VA 10000, VA 700, VA 3000, VA 20000 specifications

Rackmount Solutions offers a versatile lineup of VA series products designed for efficient power management in data centers and server environments. The VA 1000, VA 6000, VA 20000, VA 3000, and VA 700 models cater to a variety of power needs, ensuring reliable performance and robust features tailored to different operational demands.

Starting with the VA 1000, this model is compact yet powerful, providing up to 1000VA of power capacity. It features an LCD display that offers real-time information on power status, battery life, and load levels. The VA 1000 is equipped with pure sine wave output, ensuring compatibility with sensitive electronic equipment and providing protection against power surges. The unit is designed for easy integration into existing IT frameworks, with multiple outlets to accommodate various devices.

Next in the lineup, the VA 3000 model steps up the capacity to 3000VA. This unit excels in larger environments where higher power demands are common. It too features pure sine wave output and includes advanced battery management technology that optimizes performance and prolongs battery life. Its networking capabilities allow for remote management and monitoring through a web interface, providing IT managers with comprehensive control over their power infrastructure.

The VA 6000 doubles down on capacity, supporting robust applications with its 6000VA rating. It is equipped with advanced features such as surge protection, automatic voltage regulation, and a high-efficiency design that reduces energy consumption. Its modular design allows for ease of maintenance and upgrades, making it a cost-effective solution over time for growing data centers.

For the larger setups, the VA 20000 model stands out with a staggering 20000VA power capacity. Designed for high-demand applications, this unit incorporates features like redundancy and N+1 configurations to ensure uninterrupted power supply. Its scalable architecture makes it suitable for both small and large enterprises looking to future-proof their power infrastructure.

Lastly, the VA 700 model serves as an entry-level solution at 700VA. Ideal for small servers and networking devices, it offers essential features like battery monitoring and basic surge protection, making it a cost-effective choice for small business environments.

In summary, the Rackmount Solutions VA series, comprising models VA 1000, VA 3000, VA 6000, VA 20000, and VA 700, collectively offer a comprehensive suite of power management solutions. Their scalable designs, advanced technologies, and focus on efficiency make them ideal for a wide range of applications, from small offices to large data centers, ensuring reliability and performance in critical environments.