manner until all GND terminals, (-) terminals and (+) terminals are connected together. See Table 10, “Minimum Requirements for E-Series UPS Installation,” on page 40 for minimum wire gage, wire temperature and screw torque requirements.

For models E101 and E203, first remove the connection plate from the rear of the battery cabinet. Next, connect the wires from GND terminal on the UPS to GND wire on the battery cabinet, and then from (-) terminal on the UPS to the (-) terminal on the battery cabinet. Finally, connect (+) terminal on the UPS to the (+) terminal on the battery cabinet. Connect any additional battery cabinets in a “daisy-chain” manner until all GND terminals, (-) terminals and (+) terminals are connected together. See Table 10, “Minimum Requirements for E-Series UPS Installation,” on page 40 for minimum wire gage, wire temperature and screw torque requirements.

10.Carefully replace the connection plate(s) on the battery cabinet and the UPS, making sure that no wires are pinched or damaged.

11.Confirm that all input and output breakers on the UPS and battery cabinet(s) are in the OFF position.

12.Restore power source to the UPS.

WARNING: Make sure that all circuit breakers on the battery cabinet and UPS are in the“OFF” postion before removing any covers.

34

Chloride Active and E-Series UPS User Manual

Image 38
Contents Page Important Safety Instructions FCC ComplianceChloride Introduction Operational Characteristics E-Series Chloride Introduction Technical Support and Service ActiveSafety Notes Registering your Chloride Active UPSPage Display and Operation Elements Active Overload LoadFront Rear Active 700Active 2000 Active 3000 Rear ViewActive Rackmount Series SafetyInstallation and operating notes Type of Battery Packs Maximum Number of Packs Connection of a battery packBattery Cabinets Mechanical AttachmentUnit Rear View and Connections Active 700-19 and Active Active700-19Active 2000-19 and Active Active3000-19Active Installation and Commissioning Model Cabinet Batteries Commissioning of an External Battery CabinetExternal Battery Packs Operational Characteristics Active Ready for Operation Check Self TestNormal Operation, Inverter On Mains Available Battery Operation, Inverter On Mains FailureModes of Operation Bypass Operation, Inverter OFF Overload 140% Front Display Panel During Bypass Operation Overload 140%Description of the Interface Active Standard Interface COM aPin Number Condition Optional Interface COM BInterface COM a INV Shutdown Storage Maintenance ActiveCleaning Problem Possible Cause Action to Take Troubleshooting ActiveTroubleshooting Page Active Tower and Rackmount Specifications Chloride Active UPS North AmericaUPS Model Active Battery extensionSignals Mechanical DataUPS Model Active Connections Mains connections Load connectionActive Rackmount Technical Data for North American Models Operating DataBattery Lifetime Typical lifetime of the batteriesTechnical Support and Service E-Series Registering your Chloride E-Series UPSPage Display and Operation Elements E-Series Switch for at least 1 second. a tone sounds Series E61 and E101 E41 or E61Series E203 E81 or E101Series Installation and Commissioning Installation of the E-Series HardwiredPage Minimum Requirements for E-Series UPS Installation Lbs AwgWiring Diagram for the E101 Commissioning of the E-Series Starting Up the E-SeriesDryers, vacuum cleaners BPE61 Technical data of the connection cable E101 E203Self Test Modes of Operation Bypass Operation, Inverter OFF Overload 140% Description of the Interface E-Series Optional Interface COM B Emergency Power Off EPO Series Models E153X and E203X onlyMaintenance E-Series Troubleshooting E-Series Page Series Specifications Chloride E-Series UPS North AmericaBPE101 Weight lbs 337 894 Dimensions HxWxD in. mm E101XA E203XA E41XA E81 E153XA Connections Optional Power Distribution Units PDU available 4 -10 kVA Optional Power Distribution UnitsChloride Power Protection

VA 2000, VA 10000, VA 700, VA 3000, VA 20000 specifications

Rackmount Solutions offers a versatile lineup of VA series products designed for efficient power management in data centers and server environments. The VA 1000, VA 6000, VA 20000, VA 3000, and VA 700 models cater to a variety of power needs, ensuring reliable performance and robust features tailored to different operational demands.

Starting with the VA 1000, this model is compact yet powerful, providing up to 1000VA of power capacity. It features an LCD display that offers real-time information on power status, battery life, and load levels. The VA 1000 is equipped with pure sine wave output, ensuring compatibility with sensitive electronic equipment and providing protection against power surges. The unit is designed for easy integration into existing IT frameworks, with multiple outlets to accommodate various devices.

Next in the lineup, the VA 3000 model steps up the capacity to 3000VA. This unit excels in larger environments where higher power demands are common. It too features pure sine wave output and includes advanced battery management technology that optimizes performance and prolongs battery life. Its networking capabilities allow for remote management and monitoring through a web interface, providing IT managers with comprehensive control over their power infrastructure.

The VA 6000 doubles down on capacity, supporting robust applications with its 6000VA rating. It is equipped with advanced features such as surge protection, automatic voltage regulation, and a high-efficiency design that reduces energy consumption. Its modular design allows for ease of maintenance and upgrades, making it a cost-effective solution over time for growing data centers.

For the larger setups, the VA 20000 model stands out with a staggering 20000VA power capacity. Designed for high-demand applications, this unit incorporates features like redundancy and N+1 configurations to ensure uninterrupted power supply. Its scalable architecture makes it suitable for both small and large enterprises looking to future-proof their power infrastructure.

Lastly, the VA 700 model serves as an entry-level solution at 700VA. Ideal for small servers and networking devices, it offers essential features like battery monitoring and basic surge protection, making it a cost-effective choice for small business environments.

In summary, the Rackmount Solutions VA series, comprising models VA 1000, VA 3000, VA 6000, VA 20000, and VA 700, collectively offer a comprehensive suite of power management solutions. Their scalable designs, advanced technologies, and focus on efficiency make them ideal for a wide range of applications, from small offices to large data centers, ensuring reliability and performance in critical environments.