Advanced use | VISION 5000 Videoconferencing System |
External network settings
==== External Network Settings ====
Call Control:
RS366 Dialling Leased Line Data Triggered Manual
Network Clocking:
RS449/V35 Compatible
X21 Compatible
Advanced Network Settings
Previous Menu
IMPORTANT
The physical interfaces on External Networks are two
Before using the system together with external network equipment, you must specify the network parameters on this page.
Note
The system has support for up to 384/512/768 kbps using External Network (RS449/V.35/X.21) interface depending on software version.
Call control
‘RS366 Dialling’ is the only dialling protocol and would normally be used together with network clocking ‘RS449/V35 Compatible’ when the external equipment uses RS366 ports.
‘Leased Line’ is a
‘Data Triggered’ mode uses TxData (transmit data), RxData (receive data) and clock signals only. Use ‘Data Triggered’ when no handshake signals are available.
‘Manual’ should be used when no handshake signals are available, and the external equipment requires a constantly connected line.
70