2 Gently remove the misfed paper from under the fusing unit as shown in the illustration. If the paper cannot be removed, proceed to "C: Misfeed in the transport area".
The fusing unit is hot. Do not touch the fusing unit when removing misfed paper. Doing so may cause a burn or other injury.
• Do not touch the photoconductive drum (green portion) when removing the misfed paper. Doing so may cause smudges on copies.
•Do not remove the misfed paper from above the fusing unit. Unfixed toner on the paper may stain the paper transport area, resulting in smudges on copies.
3 Raise the fusing unit release lever and then close the side cover by pressing the round projections near the side cover open button. The misfeed ( ) indicator will go out and the start () indicator will light up.
C:Misfeed in the transport area
1Lower the fusing unit release lever.
See "B: Misfeed in the fusing area" (p.53).
2Open the front cover.
To open the front cover, see "TONER CARTRIDGE REPLACEMENT" (p.45).
3Rotate the feeding roller in
the direction of the arrow | Roller rotating knob |
and gently remove the |
|
misfed paper from the exit |
|
area. |
|
54