Runco VX-22I Home Theater Calibration Specifications, Industry-Standard Specifications

Page 82

Table 7-1. VX-22i Specifications (continued)

Brightness and Contrast:

Power Requirements:

Operating Environment:

Dimensions:

Weight (without lens): Regulatory Approvals:

Limited Warranty:

Cinema Standards Measurement System (CSMS) Specifications

-Brightness: 58.7 foot-Lamberts (fL)

-Contrast Ratio: 321:1

These measurements are taken from the projector in a controlled, home theater environment. All measurements are made to ANSI/NAPM IT7.228-1997 specifications using the Photo Research PR-650 SpectraColorimeter and Minolta LS-100 Luminance Meter, Video Essentials test DVD and a 1.3 gain, 72-inch wide screen. The projector is calibrated to a color temperature of 6,500K and has a minimum of 150 hours of usage.

The foot-Lambert (fL) is the unit of measurement used in commercial movie theaters to express image brightness at the screen surface. The Society of Motion Picture and Television Engineers (SMPTE) specifies 16 fL as the target image brightness for film-based projectors using an open gate (without film in the projector). More importantly, today SMPTE specifies 12 fL as the target image brightness in Digital Cinema theaters. The foot-Lambert measurement is dependent on screen size, screen gain and projector light output.

Home Theater Calibration Specifications

-Light Output: 1391 ANSI Lumens

-Contrast Ratio: 321:1

These specifications are obtained by calibrating the projector as described above for CSMS measurements.

Industry-Standard Specifications

-Light Output: 2850 ANSI Lumens

-Contrast Ratio: 4000:1

These are typical projector brightness and contrast specifications found in most companies’ sales literature. Runco includes these measurements in its literature to allow for direct comparison with other manufacturers’ projectors. These measurements are typically taken at 9,000K to 13,000K to get expected performance data when the projector is used in professional, commercial and industrial displays.

100 to 240 VAC (auto-sensing), 50/60 Hz, 530 Watts (1808.9 BTUs/hour)

41°F to 95°F (5°C to 35°C), 0% to 90% humidity (non-condensing)

See Figure 7-1

99.21 lbs. (45.00 kg)

Complies with FCC Class B, CE, C-Tick, GOST, TUV-GS, cTUV-US

Projector: Two (2) years parts and labor from the date of delivery to the end user.

Lamp: 1000 hours or six (6) months, whichever comes first.

Specifications are subject to change without notice.

68

Runco VX-22i Installation/Operation Manual

Image 82
Contents VX-22i Page TWO Year Limited Warranty For Projectors, Video Processors and ControllersEffective Warranty Date Runco INTERNATIONAL, INC Important Safety Instructions Compliance Information Declaration of ConformityFCC Part Table of Contents Operation Specifications Maintenance and TroubleshootingSerial Communications Table of Contents Xii List of Figures List of Figures Xiv Introduction About This ManualUsing This Manual If you need Turn toDescription, Features and Benefits Key Features and BenefitsOptional Accessories Controls and Functions VX-22i at a GlanceVX-22i Rear Panel VX-22i Rear PanelPower Input 100 to 240 VAC Connect the VX-22i to power here Left ButtonRS-232/485 Control Port VX-22i Rear Connector PanelService only For future use Volt 750 mA Trigger OutputsHdmi I 1 / Hdmi II 2 Digital HD3 InputVX-22i Remote Control VX-22i Remote ControlSource Selection Buttons Picture Adjustment Buttons BRT BrightnessOn / OFF VID S-Video169 Memory Preset ButtonsAspect Ratio Selection Buttons Lbox LetterboxInstallation Remote ControlStep Procedure For Details, Refer to Quick SetupIf installing a VX-22i/CineWide or VX-22i/CineWide Installation Type Installation ConsiderationsAmbient Light Lens Throw Range Throw Ratio Inches, with Lens Option96x54-inch Lens Only Anamorphic Minimum MaximumVertical and Horizontal Ceiling InstallationFloor Installation PositionHorizontal Lens Shift Example only Folded Optics Folded OpticsInstalling the Primary Projection Lens Other ConsiderationsPage Installing the Optional CineWide Lens Mount AutoScope Installing the AutoScope Lens Motor VX-22i/CineWide withRemove VX-22i with Ceiling Mount Adapters/Projector Stands AutoScope Lens Motor Installation Installing the Fixed CineWide Base Plate Mounting Connections to Connector Panel AccessConnecting Source VX-22i11. Digital DTV RGB or Component Video Connections HD1, HD2 12. Digital DTV RGB or Component Video Connections HD3 DTV or Progressive Component YPbPr SourceAnalog Computer RGB Connections See Figure 13. Analog RGB ConnectionsVideo/Composite Video Connections See Figure DVD Player, VCR Satellite Receiver Laser Disc etcRS-232 Controller ConnectionExternal Equipment Connecting 12-voltTrigger Outputs to AutoScope Lens Motor RearReceiver to Connecting an External IRConnecting to AC Power Rear PanelTurning on the Power Adjusting the Picture OrientationFocus Primary Lens AdjustmentsZoom Carriage Plate CineWide Installing and Adjusting the CineWide Anamorphic LensAssembly to Lens Motor With AutoScope or Base19. Attaching the Anamorphic Lens to the Lens Adapter Ring Adjusting the Horizontal X Lens Position Configure Lens MotorAdjust the Anamorphic TriggerPage Anamorphic Lens Top View Adjusting the Geometry Page Using the On-Screen Menus OperationInput Source Memory PresetsService Aspect RatioInput Source Main MenuAspect Ratio Hdtv programs in their Remote Aspect Ratio Control Description Key 169Select 169 to view 169 DVDs Native aspect ratioRemote Aspect Ratio Control Description Key PicturePicture Typical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Gray Yellow Cyan Green Magenta Red Blue Input Position Input PositionInformation Memory PresetsMemory Presets InformationCalibration ISF Night CalibrationISF Day Gain/Offset Refer to ISF Night Display Color, above Service ServiceHD Format ISF Day/Night presets Maintenance and Troubleshooting Lamp ReplacementFilter Replacement Side Filter Access PanelTroubleshooting Tips Symptom Possible Causes SolutionPage If you are using a PC to communicate with Serial CommunicationsInput Selection Commands Command Description ResponseAspect Ratio Commands Picture Adjust Commands Command Description Response Image Preset CommandsMenu Navigation Commands Enter or Select buttonPage Specifications VX-22i SpecificationsIndustry-Standard Specifications Home Theater Calibration SpecificationsSpecifications are subject to change without notice VX-22i Dimensions VX-22i/CineWide with AutoScope DimensionsSupported Timings PAL-B/G Page Page Runco CL-810 Owner’s Operating Manual