Runco VX-22I operation manual Quick Setup, Step Procedure For Details, Refer to

Page 28

3.2

Quick Setup

Table 3-1gives a quick overview of the VX-22i installation process. The sections following this one provide detailed instructions.

 

Note

Installation should be performed by a qualified custom video

 

installation specialist.

 

Table 3-1. Installation Overview

 

 

 

 

 

 

Step

 

 

Procedure

For Details, Refer to

 

 

page...

 

 

 

 

 

 

 

 

1

 

Choose a location for the projector

15

 

 

 

 

2

 

If installing a VX-22i/CineWide or VX-22i/CineWide

22

 

 

with AutoScope: Install fixed CineWide base plate or

 

 

 

AutoScope lens motor

 

 

 

 

 

3

 

Mount the projector

27

 

 

 

 

4

 

Connect signal sources to the projector

28

 

 

 

 

5

 

Connect external controller to RS-232 port (optional)

33

 

 

 

 

6

 

Connect 12-volt trigger outputs to AutoScope lens motor

34

 

 

and/or other equipment (optional)

 

 

 

 

 

7

 

Connect projector and lens motor (if present) to AC power

35

 

 

and power up

 

 

 

 

 

 

8

 

For rear-screen and/or ceiling-mount installations, select

36

 

 

the proper picture orientation

 

 

 

 

 

9

 

Primary lens adjustments: projected image size (zoom),

17, 37

 

 

position (shift) and focus

 

 

 

 

 

10

 

Install CineWide anamorphic lens (optional)

38

 

 

 

 

11

 

CineWide lens adjustments: position, pitch (angle),

40

 

 

geometry and focus

 

 

 

 

 

12

 

Projector calibration: adjust the following for each input;

47

 

 

save settings when finished:

 

 

 

• Aspect ratio

 

 

 

 

• Brightness

 

 

 

 

• Contrast

 

 

 

 

• Color level

 

 

 

 

• Tint

 

 

 

 

• Input position

 

 

 

 

 

 

14

Runco VX-22i Installation/Operation Manual

Image 28
Contents VX-22i Page TWO Year Limited Warranty For Projectors, Video Processors and ControllersEffective Warranty Date Runco INTERNATIONAL, INC Important Safety Instructions Compliance Information Declaration of ConformityFCC Part Table of Contents Operation Specifications Maintenance and TroubleshootingSerial Communications Table of Contents Xii List of Figures List of Figures Xiv Introduction About This ManualUsing This Manual If you need Turn toDescription, Features and Benefits Key Features and BenefitsOptional Accessories Controls and Functions VX-22i at a GlanceVX-22i Rear Panel VX-22i Rear PanelPower Input 100 to 240 VAC Connect the VX-22i to power here Left ButtonVX-22i Rear Connector Panel Service only For future useRS-232/485 Control Port Volt 750 mA Trigger OutputsHdmi I 1 / Hdmi II 2 Digital HD3 InputVX-22i Remote Control VX-22i Remote ControlPicture Adjustment Buttons BRT Brightness On / OFFSource Selection Buttons VID S-VideoMemory Preset Buttons Aspect Ratio Selection Buttons169 Lbox LetterboxInstallation Remote ControlStep Procedure For Details, Refer to Quick SetupIf installing a VX-22i/CineWide or VX-22i/CineWide Installation Type Installation ConsiderationsAmbient Light Throw Range Throw Ratio Inches, with Lens Option 96x54-inchLens Lens Only Anamorphic Minimum MaximumCeiling Installation Floor InstallationVertical and Horizontal PositionHorizontal Lens Shift Example only Folded Optics Folded OpticsInstalling the Primary Projection Lens Other ConsiderationsPage Installing the Optional CineWide Lens Mount AutoScope Installing the AutoScope Lens Motor VX-22i/CineWide withRemove VX-22i with Ceiling Mount Adapters/Projector Stands AutoScope Lens Motor Installation Installing the Fixed CineWide Base Plate Mounting Connector Panel Access Connecting SourceConnections to VX-22i11. Digital DTV RGB or Component Video Connections HD1, HD2 12. Digital DTV RGB or Component Video Connections HD3 DTV or Progressive Component YPbPr SourceAnalog Computer RGB Connections See Figure 13. Analog RGB ConnectionsVideo/Composite Video Connections See Figure DVD Player, VCR Satellite Receiver Laser Disc etcRS-232 Controller ConnectionConnecting 12-volt Trigger Outputs toExternal Equipment AutoScope Lens Motor RearConnecting an External IR Connecting to AC PowerReceiver to Rear PanelTurning on the Power Adjusting the Picture OrientationFocus Primary Lens AdjustmentsZoom Installing and Adjusting the CineWide Anamorphic Lens Assembly to Lens MotorCarriage Plate CineWide With AutoScope or Base19. Attaching the Anamorphic Lens to the Lens Adapter Ring Configure Lens Motor Adjust the AnamorphicAdjusting the Horizontal X Lens Position TriggerPage Anamorphic Lens Top View Adjusting the Geometry Page Using the On-Screen Menus OperationMemory Presets ServiceInput Source Aspect RatioInput Source Main MenuAspect Ratio Remote Aspect Ratio Control Description Key 169 Select 169 to view 169 DVDsHdtv programs in their Native aspect ratioRemote Aspect Ratio Control Description Key PicturePicture Typical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Gray Yellow Cyan Green Magenta Red Blue Input Position Input PositionMemory Presets Memory PresetsInformation InformationCalibration ISF Night CalibrationISF Day Gain/Offset Refer to ISF Night Display Color, above Service ServiceHD Format ISF Day/Night presets Maintenance and Troubleshooting Lamp ReplacementFilter Replacement Side Filter Access PanelTroubleshooting Tips Symptom Possible Causes SolutionPage If you are using a PC to communicate with Serial CommunicationsInput Selection Commands Command Description ResponseAspect Ratio Commands Command Description Response Image Preset Commands Menu Navigation CommandsPicture Adjust Commands Enter or Select buttonPage Specifications VX-22i SpecificationsIndustry-Standard Specifications Home Theater Calibration SpecificationsSpecifications are subject to change without notice VX-22i Dimensions VX-22i/CineWide with AutoScope DimensionsSupported Timings PAL-B/G Page Page Runco CL-810 Owner’s Operating Manual