Vidikron SERIES 1080p manual Typical Test Pattern for Adjusting Sharpness

Page 60

Operation

Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust sharpness, select Sharpness from the Picture Adjust menu and press ENTER. On your external test pattern source, select a pattern like the one shown in Figure 4-5.Adjust as needed, looking for white edges around the transitions from black to gray and differently-sized lines in the “sweep” patterns at the top and bottom. Lower the Sharpness setting to eliminate them.

Figure 4-5. Typical Test Pattern for Adjusting Sharpness

The Sharpness setting has no effect if the Video Filter (described on

Note

page 52) is set to 0.

 

Color Temp.: The Vision 70 has six memory settings for Color Temperature. Four of these settings are factory set to default as follows:

0 -- Original lamp color temperature

1 -- 5400 kelvins

2 -- 6500 kelvins

3 -- 8500 kelvins

4 -- Custom

5 -- Custom

Custom 4 and 5 memory are installer-adjustable and can be used to create custom settings. There are nine adjustable “white balance” parameters available for the Custom 4 and 5 settings (three each for red, green and blue). These are described later in this section; refer to Service on page 54.

48

Vidikron Vision 70 Series Owner’s Operating Manual

Image 60
Contents Series 1080p DLP Projectors Page TWO Year Limited Warranty For Projectors, Video Processors and ControllersEffective Warranty Date Vidikron Safety Precautions 1Table of Contents Maintenance and Troubleshooting OperationSerial Communications Table of Contents 1List of Figures List of Figures Xii 1Introduction About This ManualUsing This Manual They also provide supplemental informationPerformance or cause a malfunction If you need Turn toDescription, Features and Benefits Optional Accessories POWER/STANDBY LED Indicates power status as follows Vision 70 at a Glance565 Vision 70 Connector Panel Cable Access Door Open to access connectorsBuilt-In Keypad Vision 70 Remote Control Vision 70 Remote ControlOn / OFF Source Selection Buttons Comp 1 SD ComponentVID S-Video Comp 2 HD ComponentMemory Preset Buttons Cursor KeysPicture-In-Picture PIP / Picture-By-Picture PBP Controls VAC V2 Aperture ControlRemote Control/Built-In Keypad Functional Comparison Motorized Lens Controls3Installation Remote ControlOperation Quick Setup Installation OverviewStep Procedure For Details, Refer to If installing a Vision 70/CineWide or Vision 70/CineWideInstallation Considerations Projector Installation OptionsInstallation Type Advantages ConsiderationsThrow Ratios for the Vision 70 Series Throw Range Throw RatioProjector Model VisionCeiling Installation Floor InstallationVertical and Horizontal PositionFolded Optics Installing the Optional CineWide Lens Mount Vision 70/CineWide with AutoScope Lens Motor Bottom View Ceiling Mount Extension Brackets Ceiling mounting plate Vision 70/CineWide with Lens Base PlateAdjusting the Projector Mounting the VisionFloor Mounting Upright Connector Panel Access Connecting SourceConnections to the Vision RGB Connections 10. Progressive Component Video Connections DTV or Progressive Component YPbPr SourceDTV Source DVD Player, VCR Satellite Receiver Etc 11. Composite, S-Video and Component Video ConnectionsConnection 12. RS-232 Control System Connection14. Connecting the 12-Volt Trigger Output to Other Equipment Turning on the Power Focus Zoom Vertical Lens Shift Installing and Adjusting the CineWide Anamorphic Lens Vision 70/CineWideAdjusting the Lens Height Y Anamorphic Lens Top View Adjustment Vision 70/CineWide withAutoScope Attach Lens Mounting Assembly to Lens Motor Carriage Plate 17. Attaching the Anamorphic Lens to the Lens Adapter RingAdjusting the Horizontal X Lens Position Installation Anamorphic Lens Top View Adjusting the Geometry Using Picture-In-Picture/ Picture-By-Picture PIP/PBP 4OperationSelecting Video Memory Selecting an Aspect Ratio Selecting An Input SourceUsing the On-Screen Menus Adjust InstallationService PicturePicture Adjust Main MenuPerform the adjustments in the order listed here Typical Pluge Pattern for Adjusting BrightnessGray Yellow Cyan Green Magenta Red Blue Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness Image Option Image OptionAspect Ratio Settings DescriptionRemote Projector Status Installation Exit to return to the previous menu or Menu to exitService ServiceOperation Operation Remote Control ISF Calibration ISF CalibrationOperation Operation 5Maintenance and Troubleshooting Lamp ReplacementLamp assembly for replacement Troubleshooting Tips Troubleshooting ChartSymptom Possible Causes Solution Correct Vision 70 input Maintenance and Troubleshooting Serial Command Syntax RS-232 Connection and Port ConfigurationSerial Commands 6Serial CommunicationsSerial Communications Serial Commands Serial Commands 7Specifications Vision 70 SpecificationsHome Theater Calibration Specifications Industry-Standard SpecificationsPower Requirements DimensionsLimited Warranty Specifications are subject to change without noticeRegulatory Approvals Vision 70 Dimensions Vision 70 DimensionsVidikron Vision 70 Series Owner’s Operating Manual Power-cycle the projector to see the change Page Vidikron