Maintenance and Troubleshooting
If the status code display on the back of the projector shows one of the following values, you | Error Codes | ||
have encountered a likely system error requiring the attention of a qualified service |
| ||
technician. Acknowledge and clear the error by pressing EXIT twice on the |
| ||
keypad. Try resetting the projector by powering it off, allowing it to cool and powering it on |
| ||
again. Refer to Table |
| ||
The specific code number identifies the source of the error detected, and is particularly useful |
| ||
in cases where the projector is far away. For example, the code “27” means the lamp could |
| ||
not be turned on. |
|
| |
Table |
| ||
|
|
|
|
Code |
| Description |
|
|
|
|
|
|
| General |
|
|
|
|
|
12 |
| Software bug. Contact dealer or Vidikron Technical Support. |
|
|
|
|
|
13 |
| CRC error in flash ROM. Download new software. |
|
|
|
|
|
14 |
|
| |
|
|
|
|
15 |
| Attempting to download code without being in boot mode. |
|
|
|
|
|
16 |
| Invalid interrupt. Power off/on. If it persists, contact dealer or Vidikron Technical |
|
|
| Support. |
|
|
|
|
|
17 |
| User forced system to stay in boot mode. |
|
|
|
|
|
18 |
| Jumper for programming boot not installed. |
|
|
|
|
|
|
| Lamp Failures |
|
|
|
|
|
20 |
| Lamp turned on unexpectedly (fault related to ballast). |
|
|
|
|
|
21 |
| Lamp airflow low, overheating imminent. |
|
|
|
|
|
23 |
| Cannot read valid ballast ID. |
|
|
|
|
|
26 |
| Lamp 1 Interlock: lamp door open, lamp not installed. |
|
|
|
|
|
27 |
| Can’t turn lamp on. |
|
|
|
|
|
28 |
| Lamp turned off unexpectedly. |
|
|
|
|
|
29 |
| Lamp ballast overheated. |
|
|
|
| |
Note: To clear a system error, press the EXIT key (on the projector’s |
| ||
reset the projector by powering it off, allowing it to cool and powering it on again. Contact your Vidikron |
| ||
dealer or Vidikron technical support if the error persists. |
| ||
|
|
|
|
Vision Model 140/150 Owner’s Operating Manual | 87 |