Vidikron 140/150 manual Installing the Optional CineWide Lens Mount

Page 39

If you are installing a Vision 140/150 with the optional CineWide or CineWide with AutoScope system, proceed as follows to install the anamorphic lens mounting assembly (stationary base plate or AutoScope lens motor).

3.5

Installing the Optional CineWide Lens Mount

1. Do not install the CineWide lens yet, only the mounting plate or lens

Note motor. You will install the CineWide lens after you install the projector and adjust the primary lens.

2.Some of the following steps are necessary only for CineWide with AutoScope installations.

(Skip this step if you are installing a fixed CineWide anamorphic lens.)

Place the projector upside down on a blanket or other soft surface. Loosen and remove the two front feet on the projector.

The anamorphic lens mounting kit is partially pre-assembled at the

Note factory – the AutoScope lens motor and lens mounting assemblies are both fully assembled.

CineWide with AutoScope: Line up the eight mounting holes on the lens motor housing with those on the bottom of the projector.

Secure the motor to the projector with the eight screws provided for this purpose.

Fixed CineWide: Line up the seven mounting holes on the lens mount base plate with those on the bottom of the projector, directly below the primary lens. Secure the base plate to the projector with the screws provided for this purpose.

Remove Projector Front Feet (CineWide with AutoScope)

Install Anamorphic Lens Motor (CineWide with AutoScope) or Base Plate (fixed CineWide)

Vision Model 140/150 Owner’s Operating Manual

27

Image 39
Contents 140/150 Page For Projectors, Video Processors and Controllers TWO Year Limited WarrantyEffective Warranty Date Vidikron Safety Precautions 1Table of Contents Viii Serial Communications Maintenance and TroubleshootingSpecifications OperationTable of Contents 1List of Figures List of Figures Carriage return must be used after each command or string About This ManualThis Manual If you need Turn to Using This ManualThey also provide supplemental information Performance or cause a malfunctionDescription, Features and Benefits Optional Accessories Vision 140/150 Top/Rear/Front View Vision 140/150 at a GlanceLED Status Display Adjustable FeetTOP IR Sensor BUILT-IN Keypad Input PanelInput 1 Rgbhv Vision 140/150 Input PanelRemote EthernetVision 140/150 Rear-Panel Keypad Right Button UP ButtonLeft Button Down ButtonVHD Controller Front Panel IR SensorVacuum Fluorescent Display Composite Video Input VHD Controller Rear PanelHdmi OUT InputsMain AC Fuse Power Input 100 to 240 VACMain Power Switch RS-232 Control PortVHD Controller/Vision 140/150 Remote Control Vision 140/150 Remote Control UnitIR Output Indicator LightRETURN/EXIT Cinema ISF DAYControls and Functions Remote Control To install batteries in the remote controlOperation Installation Quick Setup Installation OverviewStep Procedure For Details, Refer to Advantages Considerations Installation ConsiderationsProjector Installation Options Installation TypeScreen Vision 140/150 Lens Options and Throw RatiosThrow Ratio With 126.9x54-inchVertical and Horizontal Lens Ceiling InstallationFloor Installation PositionHorizontal Lens Shift Example only Vertical and Horizontal Lens Shift Limits Folded Optics Lens Assembly Front View Installing the Projection LensAnamorphic lens mounting kit is partially pre-assembled at Installing the Optional CineWide Lens MountLens motor installed Ceiling-mounting an AutoScope-equipped projectorFloor-Mount Angle Adjusting the ProjectionMounting the Vision 140/150 Floor Mounting UprightConnecting the VHD Connections to the Vision 140/150 and VHD Controller140/150 Connecting Source Hdmi Connections See FigureController 11. Digital DTV RGB or Component Video Connections Digital DTV RGB or Component Video Connections See FigurePersonal Computer Analog Computer RGB Connections See FigureDVD Player, VCR Satellite Receiver Laser Disc etc Composite/S-Video/Component Video Connections See Figure14. RS-232 Control System Connection ConnectionEquipment Connecting 12-Volt TriggerConnecting an External IR Receiver to the VHD Controller Power sourceProjector Component SD Ntsc 480i 169 V150 Turning on the PowerFocus Zoom Vertical and Horizontal Lens Shift Adjusting the Picture Orientation Primary Lens AdjustmentsPlate fixed CineWide Installing and Adjusting the CineWide Anamorphic LensHorizontal Position X Adjustment Installation Geometry Anamorphic Lens Top ViewWrong Position Calibrating Projector Input 2 DVI Main 17. TheaterMaster Remote Control for Vision 140/150Control Functions Navigating the Projector DisabledLtrbox night Vhd 720p16x9 night 4x3 nightInterlace Name 16x9 nightNumber Sync 26.97 kHz Input 23.98 Hz Menu Auto Source Locked Previous Channel Next ChannelNative aspect ratio is with the primary lens only. With an SupportSize and Position Menu Installation Picture Quality Menu Adjust Pixel Tracking before Pixel PhaseWhite Balance Uncheck this item before exiting this menu There must be at least two consecutive white pixels presentEach setting Back Porch Clipping Detector Color Enable RedLumaCal lamp calibration takes approximately two minutes Installation MenuAbove, the Automatic Lens Calibration setting has no effect Factors Working With the LampValue only 1246 may represent 3500 lumens, for example RVR Easily maintained as the lamp agesInstallation 4Operation Using the On-Screen MenusAspect Ratio ISF PresetsService Input SourceMain Menu Input SourceAspect Ratio Hdtv programs in their Aspect Ratio SettingsDescription 169With a 2.351 screen and a RemotePicture Perform the adjustments in the order listed hereTypical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Gray Yellow Cyan Green Magenta Red Blue Input Position Typical Test Pattern for Adjusting SharpnessInformation ISF PresetsISF Night You must enter a passcode to access the Calibration menuCalibration Should be used by ISF-certified technicians onlyOperation Service You must enter a passcode to access the Service menuDo not change the Type setting in this menu Keystone Correction Vertical Keystone CorrectionHD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Operation Operation Lamp cover 2 screws Lamp and Filter ReplacementRemoving the Lamp RVR Removing the Primary Lens Lens ReplacementTroubleshooting Tips Troubleshooting ChartSymptom Possible Causes Solution Trigger CineWide with SymptomVision 140/150 Error Codes Description GeneralLamp Failures Code Description Power and Cooling Code Description Code Description Miscellaneous Multiple serial commands Serial Command SyntaxRS-232 Connection and Port Configuration Serial CommandsAspect Ratio Commands Image Preset Commands Output Shift Commands Command Value Stored? Description Miscellaneous CommandsEnter key Serial Communications Vision 140/150 Specifications Vision 140/150 SpecificationsDimensions Home Theater Calibration SpecificationsIndustry-Standard Specifications Power Requirements VisionVHD Controller Specifications Vision 140/150 Dimensions Vision 140/150 DimensionsPage Vidikron