If infrared signals from the remote control cannot reach the VHD Controller due to excessive distance or obstructions such as walls or cabinet doors, you can connect an external IR receiver to the VHD Controller to extend the range of the remote control. See Figure 3-16.

VHD Controller Rear Panel

SYSTEM CONTROL INTERFACE

CAUTION

!

 

RISK OF ELECTRIC SHOCK

 

DO NOT OPEN

 

AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR

TRIGGERS

CAUTION: TO REDUCE THE RISK OF ELECTRIC

SHOCK, DO NOT REMOVE COVER. NO USER-

SERVICEABLE PARTS INSIDE. REFER SERVICING

TO QUALIFIED SERVICE CENTER.

1

2

3

IR

WARNING: TO REDUCE THE RISK OF FIRE

OR ELECTRIC SHOCK, DO NOT EXPOSE

THIS APPLIANCE TO RAIN OR MOISTURE.

S-Video 1

100-230VAC 50-60 Hz, 165 Watts Max

Video

S-Video 2 RS-232 Out

RS-232 Control

Made In USA

Ring = +5V

IR ReceiverTip = IR Input

Sleeve = Ground

Remote

(3.5-mm

Control

mini phono

 

 

plug)

Connecting an External IR Receiver to the VHD Controller

Figure 3-16. External IR Receiver Connection

When an external IR receiver is connected to the wired IR input, the

Note

built-in IR sensor on the VHD Controller is disabled.

 

 

 

The Vision 140/150 system includes two (2) AC power cords (one each for the VHD Controller

Connecting to AC Power

and projector).

 

 

VHD Controller: Plug the female end of one power cord into the AC receptacle on the rear of the VHD Controller. Connect the other end to your AC power source (100 to 240 VAC).

Projector: Similarly connect the Vision 140/150 to a nearby AC outlet. The input voltage to a Vision 140 must be between 100 and 240 VAC. The input voltage to a Vision 150 must be between 200 and 240 VAC.

The LED status window displays an active pattern of segments to indicate the projector is changing its state from powered down to powered up. “--” appears in the display when the projector is ready to be turned on.

AutoScope Lens Motor: With AutoScope-equipped projectors, a third power cord is provided for the lens motor. Plug the female end of the AC power cord into the AC receptacle on the rear of the lens motor assembly. Connect the other end to a 110 VAC power source.

Caution

The input voltage to the AutoScope lens motor must be between 100 and

120 VAC. Do not connect the AutoScope lens motor to a 200-240 VAC

 

power source!

Vision Model 140/150 Owner’s Operating Manual

37

Image 49
Contents 140/150 Page For Projectors, Video Processors and Controllers TWO Year Limited WarrantyEffective Warranty Date Vidikron Safety Precautions 1Table of Contents Viii Specifications Maintenance and TroubleshootingOperation Serial CommunicationsTable of Contents 1List of Figures List of Figures About This Manual Carriage return must be used after each command or stringThis Manual They also provide supplemental information Using This ManualPerformance or cause a malfunction If you need Turn toDescription, Features and Benefits Optional Accessories Vision 140/150 Top/Rear/Front View Vision 140/150 at a GlanceTOP IR Sensor BUILT-IN Keypad Adjustable FeetInput Panel LED Status DisplayRemote Vision 140/150 Input PanelEthernet Input 1 RgbhvVision 140/150 Rear-Panel Keypad Left Button UP ButtonDown Button Right ButtonIR Sensor VHD Controller Front PanelVacuum Fluorescent Display Hdmi OUT VHD Controller Rear PanelInputs Composite Video InputMain Power Switch Power Input 100 to 240 VACRS-232 Control Port Main AC FuseVHD Controller/Vision 140/150 Remote Control Vision 140/150 Remote Control UnitLight IR Output IndicatorRETURN/EXIT Cinema ISF DAYControls and Functions To install batteries in the remote control Remote ControlOperation Installation Installation Overview Quick SetupStep Procedure For Details, Refer to Projector Installation Options Installation ConsiderationsInstallation Type Advantages ConsiderationsThrow Ratio Vision 140/150 Lens Options and Throw RatiosWith 126.9x54-inch ScreenFloor Installation Ceiling InstallationPosition Vertical and Horizontal LensHorizontal Lens Shift Example only Vertical and Horizontal Lens Shift Limits Folded Optics Lens Assembly Front View Installing the Projection LensAnamorphic lens mounting kit is partially pre-assembled at Installing the Optional CineWide Lens MountCeiling-mounting an AutoScope-equipped projector Lens motor installedFloor-Mount Mounting the Vision 140/150 Adjusting the ProjectionFloor Mounting Upright AngleConnections to the Vision 140/150 and VHD Controller Connecting the VHD140/150 Hdmi Connections See Figure Connecting SourceController 11. Digital DTV RGB or Component Video Connections Digital DTV RGB or Component Video Connections See FigurePersonal Computer Analog Computer RGB Connections See FigureDVD Player, VCR Satellite Receiver Laser Disc etc Composite/S-Video/Component Video Connections See Figure14. RS-232 Control System Connection ConnectionEquipment Connecting 12-Volt TriggerPower source Connecting an External IR Receiver to the VHD ControllerProjector Component SD Ntsc 480i 169 V150 Turning on the PowerFocus Zoom Vertical and Horizontal Lens Shift Adjusting the Picture Orientation Primary Lens AdjustmentsPlate fixed CineWide Installing and Adjusting the CineWide Anamorphic LensHorizontal Position X Adjustment Installation Geometry Anamorphic Lens Top ViewWrong Position Calibrating Projector Input 2 DVI Main 17. TheaterMaster Remote Control for Vision 140/150Control Functions Navigating the Projector Disabled16x9 night Vhd 720p4x3 night Ltrbox nightNumber Sync 26.97 kHz Input 23.98 Hz Menu Name 16x9 nightAuto Source Locked Previous Channel Next Channel InterlaceSupport Native aspect ratio is with the primary lens only. With anSize and Position Menu Installation Picture Quality Menu Adjust Pixel Tracking before Pixel PhaseWhite Balance Uncheck this item before exiting this menu There must be at least two consecutive white pixels presentEach setting Back Porch Clipping Detector Color Enable RedLumaCal lamp calibration takes approximately two minutes Installation MenuAbove, the Automatic Lens Calibration setting has no effect Factors Working With the LampValue only 1246 may represent 3500 lumens, for example RVR Easily maintained as the lamp agesInstallation 4Operation Using the On-Screen MenusService ISF PresetsInput Source Aspect RatioInput Source Main MenuAspect Ratio Description Aspect Ratio Settings169 Hdtv programs in theirWith a 2.351 screen and a RemotePicture Perform the adjustments in the order listed hereTypical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Gray Yellow Cyan Green Magenta Red Blue Input Position Typical Test Pattern for Adjusting SharpnessInformation ISF PresetsCalibration You must enter a passcode to access the Calibration menuShould be used by ISF-certified technicians only ISF NightOperation You must enter a passcode to access the Service menu ServiceDo not change the Type setting in this menu Keystone Correction Vertical Keystone CorrectionHD/RGB 1 and HD/RGB 2 Color Space Select Auto, RGB or YUV Operation Operation Lamp cover 2 screws Lamp and Filter ReplacementRemoving the Lamp RVR Removing the Primary Lens Lens ReplacementTroubleshooting Chart Troubleshooting TipsSymptom Possible Causes Solution Trigger CineWide with SymptomDescription General Vision 140/150 Error CodesLamp Failures Code Description Power and Cooling Code Description Code Description Miscellaneous RS-232 Connection and Port Configuration Serial Command SyntaxSerial Commands Multiple serial commandsAspect Ratio Commands Image Preset Commands Output Shift Commands Value Stored? Description Miscellaneous Commands CommandEnter key Serial Communications Vision 140/150 Specifications Vision 140/150 SpecificationsIndustry-Standard Specifications Home Theater Calibration SpecificationsPower Requirements Vision DimensionsVHD Controller Specifications Vision 140/150 Dimensions Vision 140/150 DimensionsPage Vidikron