Altinex MT104-100/103 manual Rmg, 27. RD, Clm

Page 17

MULTI-TASKER™

Command Format: [RMCn1Cn2…GkUi]

Cn

= Card ID (n= # from 1 to max slots)

Gk

= Group number (k = # from 1-8)

Ui

= Unit ID (i = # from 0-9)

Example:

Group 1 consists of the cards located in slots numbered 1, 2, 3, 4 and 5. Remove just cards #4 and #5 from the group by sending the command [RMC4C5G1]. The system will return the following feedback:

G1=C1C2C3

26.[RMG]

This command may be used to delete an entire group, or all groups.

REMOVE ONE GROUP MEMBERS

Remove all the members from the group, effectively deleting the group.

Command Format: [RMGkUi]

Gk = Group number (k = # from 1-8)

Ui = Unit ID (i = # from 0-9)

Example:

Group 1 consists of the cards located in slots number 1, 2 and 3. Remove all cards from the group by sending the command [RMG1]. The system will return the following feedback:

G1=EMPTY

REMOVE ALL GROUPS

Remove all the members from every group, effectively deleting all groups.

Command Format: [RMGÜUi]

Ui = Unit ID (i = # from 0-9)

Example:

Group 1 consists of cards 1 and 2. Group 2 consists of cards 1, 2, 3, 4 and 5. Delete all the groups by sending the command [RMGÜ]. The system will return the following feedback:

G1-G8:EMPTY

400-0082-005

16

27.[RD]

This command reads and then displays the members in each group.

Command Format: [RDGkUi]

Gk = Group number (k = # from 1-8)

Ui = Unit ID (i = # from 0-9)

Example:

The cards in slots 1, 2 and 19 are part of group 5. Read the member data for group 5, by sending the command [RDG5]. The system will return feedback as follows:

G1=C1C2C19

The feedback shows G1 (Group 1) and then the cards that make up Group 1. In this case, Group 1 includes C1, C2 and C19.

28.[CLM]

This command removes the members in a group and leaves the group empty. It is equivalent to sending the [RMGkUi] command without card references.

Command Format: [CLMGkUi]

Gk = Group number (k = # from 1-8)

Ui = Unit ID (i = # from 0-9)

Example:

Group 5 of Unit ID 1 contains the cards in slots 1, 2 and 19. Read the member data for group 5 of Unit ID 1. Send the command [RDG5U1] and receive the following feedback:

G1=C1C2C19

Now, clear group 5 by sending the command [CLMG5U1]. Reread the member data as above and note the following feedback:

G1=EMPTY

16

Image 17
Contents MT104-100/103 Troubleshooting Guide Installation Precautions / Safety WarningsCleaning GeneralMechanical Technical SpecificationsMT104-100/103 Electrical Description of MT104-100Diagram 1 Rgbhv Configuration Application DiagramsDiagram 2 C-VIDEO Configuration Diagram 3 Internal View Description of Commands Installing Your MT104-100Operation RS-232 ControlCnS VERSTA ?CnExample Path OptionFeedback Option OFFMULTI-TASKER FBD CLR Test SIDn RSISIDnCi SID+Help RSN24. WR RMCCLM RMG27. RD Menu Command Definitions Menu ModeSTA OFFMenu Types Using Menu ModeMain Menu SUB MenusMenu Mode Examples Save this SETTING?Current Selection this Card ESCLED is Blinking RED Troubleshooting GuideLED is not on No Display Limited WARRANTY/RETURN PolicyAltinex Policy