Chapter 3: Troubleshooting
Check the FAULT LED. During normal operations, the LED remains off, except for periods when the management software is saving a change to its configuration. If it remains on for an extended period, do the following:
Try resetting the switch by disconnecting and reconnecting the AC power cord. If the switch is a DC model, reset the unit by powering off and the powering on the DC circuit.
If the FAULT LED remains ON, try downloading a new version of the switch’s management software through the
If the LED remains on even after you have tried the above suggestions, the switch may be having a hardware problem. Contact your Allied Telesis representative for assistance.
Cannot Establish a Local Management Session
If you are unable to establish a local management session with the switch through the
Check to be sure that the
Check to be sure that you are using a
Check to be sure that the operating parameters on the terminal or the terminal emulation program, if you are using a personal computer, have been set correctly. The default settings for “Planning the Installation” on page 52the
80