Bosch Appliances LE10 user manual Operation, Standby mode, Normal mode modes 1

Page 16

16 en Operation

LE10 Radio Receiver

 

 

6Operation

6.1Standby mode

The LE10 Radio Receiver enters standby mode when the power supply is connected. Both relays are off. See Section 4.2.1 Mode indication after power on, page 12.

6.1.1Standby with no transmitter programmed

Device behavior

The green LED stays permanently on.

The red LED blinks 3 times every 10 seconds.

6.1.2Standby with at least one transmitter programmed

Device behavior

The green LED stays permanently on.

The red LED stays permanently off.

6.2Normal mode (modes 1 and 2)

6.2.1Activation of a transmitter in normal mode

Device behavior

The green LED stays permanently on. When a matched transmitter is activated:

The red LED lights up permanently for 10 seconds.

Relay 1 switches on for 10 seconds.

Relay 2 stays off.

If the same or another matched transmitter is activated within 10 seconds, the alarm will be retriggered for 10 seconds.

Device behavior when a transmitter has a low battery

The green LED stays permanently on. When the transmitter is activated:

The red LED blinks twice for 2 seconds, then lights up permanently for 8 seconds. It then blinks once every 10 seconds.

Relay 1 switches on for 10 seconds.

F.01U.278.517 V2.0 2012.11

User Manual

Bosch Security Systems

Image 16
Contents LE10 Radio Receiver Page Table of Contents Technical data Safety instructions General safety instructionsEnvironmental conditions Electrostatic Discharge ESDGeneral description Product informationCompatible transmitters Mode Name Description Main applicationsDescription of the different modes LE10 Radio Receiver as small stand alone call systemMode Name Description Installation Connecting the power supplyPower supply with the RJ12 power socket Power supply connected to a wired installationWall installation Dimensions of the backside of the LE10 Radio ReceiverConnecting ports Connection compartmentMode indication after power on Mode selectionMode Description Switch number Enter programming mode ProgrammingProgram a transmitter in modes 1, 2 or To start programmingDelete all transmitters Delete a transmitterTo start deleting Program a door address in modes 3 or Programming in modes 6 orNormal mode modes 1 Standby modeOperation Dementia mode Activation of a MIYS37L Wristband TransmitterDetection of a MIYS37E Wristband Transmitter alone Remote control mode Dementia with Accompany modeActivation of a programmed transmitter Daily message with battery-low signal Open receiver modes 6Daily messages in modes 1, 2 or Activation of a transmitter in the reception rangeReset of a battery-low indication with button T1 Extended MIYN46 mode 8, only with SWStandby Battery-low indication Dual channel receiver mode 9, only with SWBattery low indication until the battery is exchanged Technical data ABSBosch Security Systems