Bosch Appliances LE10 user manual Open receiver modes 6, Daily messages in modes 1, 2 or

Page 20

20 en Operation

LE10 Radio Receiver

 

 

6.5.2Activation of a programmed transmitter with a

battery-low message or with a new battery

The behavior of the device is the same as in

Section 6.2.1 Activation of a transmitter in normal mode, page 16.

6.6Open receiver (modes 6 and 7)

6.6.1Activation of a transmitter in the reception range

Device behavior

The green LED stays permanently on.

The red LED lights up for 10 seconds.

Relay 1 switches on for 10 seconds.

Relay 2 switches on for 2 seconds.

Activation of any transmitter during these 10 seconds will retrigger the procedure.

NOTICE!

In these modes 6 and 7, there is no battery-low indication.

6.7Daily messages in modes 1, 2 or 5

6.7.1Daily message with battery-low signal

Device behavior

The green LED stays permanently on.

Upon receiving a daily message with battery-low signal:

The red LED blinks every 10 seconds.

Relay 1 stays off.

Relay 2 switches on, until the battery is changed.

When the battery is changed, the red LED and Relay 2 switch off if a daily message or a transmitter activation is detected.

NOTICE!

In Normal mode 2, the red LED is deactivated regarding battery- low indication and will not show any indication.

F.01U.278.517 V2.0 2012.11

User Manual

Bosch Security Systems

Image 20
Contents LE10 Radio Receiver Page Table of Contents Technical data Safety instructions General safety instructionsEnvironmental conditions Electrostatic Discharge ESDCompatible transmitters Product informationGeneral description Mode Name Description Main applicationsDescription of the different modes LE10 Radio Receiver as small stand alone call systemMode Name Description Installation Connecting the power supplyPower supply with the RJ12 power socket Power supply connected to a wired installationWall installation Dimensions of the backside of the LE10 Radio ReceiverConnecting ports Connection compartmentMode Description Switch number Mode selectionMode indication after power on Enter programming mode ProgrammingProgram a transmitter in modes 1, 2 or To start programmingTo start deleting Delete a transmitterDelete all transmitters Program a door address in modes 3 or Programming in modes 6 orOperation Standby modeNormal mode modes 1 Dementia mode Activation of a MIYS37L Wristband TransmitterDetection of a MIYS37E Wristband Transmitter alone Activation of a programmed transmitter Dementia with Accompany modeRemote control mode Daily message with battery-low signal Open receiver modes 6Daily messages in modes 1, 2 or Activation of a transmitter in the reception rangeStandby Extended MIYN46 mode 8, only with SWReset of a battery-low indication with button T1 Battery low indication until the battery is exchanged Dual channel receiver mode 9, only with SWBattery-low indication Technical data ABSBosch Security Systems