Bosch Appliances LE10 user manual Mode Name Description

Page 8

8 en Product information

LE10 Radio Receiver

 

 

 

 

 

 

 

Mode

Name

Description

 

 

 

4

Dementia with

This mode allows to connect the LE10 Radio

 

Accompany

Receiver to a wired emergency call system, in

 

 

which the Accompany function can be

 

 

implemented. It will wait 10 seconds after

 

 

receiving a signal from a MIYS37L transmitter.

 

 

If it detects a MIYS37E transmitter in this lapse

 

 

of time, no alarm is generated. If not, Relay 1 is

 

 

activated for 2 seconds.

 

 

 

5

Remote control

20 wireless transmitters can be programmed.

 

 

Per sequence, only the same transmitter can

 

 

switch on and off the Relay1. A battery-low

 

 

signal is indicated by the red LED and Relay 2.

 

 

 

6

Open receiver

No wireless transmitter needs to be

 

 

programmed. Any transmitter within reception

 

 

range of the LE10 Radio Receiver can activate

 

 

the device.

 

 

 

7

Open receiver with

Same functions as in mode 6, but with

 

reduced range

reduced range. This functionality is designed

 

 

to improve reception of transmitters located

 

 

closer to the LE10 Radio Receiver.

 

 

 

8

Extended MIYN46

Additional MIYN46 transmitters can be

 

transmitter

programmed. Behavior is similar to normal

 

programming

mode 1, with certain differences according to

 

(only with SW 1.10)

the transmitter that is activated.

 

 

 

9

Dual channel receiver

Only MIYS37 wireless transmitters can be

 

(only with SW 1.10)

programmed. Calls are indicated by Relay 1 or

 

 

Relay 2, according to the slot in which the

 

 

MIYS37 wireless transmitter is programmed. A

 

 

battery-low signal is indicated by the red LED.

 

 

 

 

 

 

 

 

NOTICE!

Factory setting is normal mode 1, in which 20 wireless transmitters can be programmed. Calls are indicated by the red LED and Relay 1. A battery-low signal is indicated by the red LED and Relay 2.

F.01U.278.517 V2.0 2012.11

User Manual

Bosch Security Systems

Image 8
Contents LE10 Radio Receiver Page Table of Contents Technical data Safety instructions General safety instructionsEnvironmental conditions Electrostatic Discharge ESDCompatible transmitters Product informationGeneral description Mode Name Description Main applicationsDescription of the different modes LE10 Radio Receiver as small stand alone call systemMode Name Description Installation Connecting the power supplyPower supply with the RJ12 power socket Power supply connected to a wired installationWall installation Dimensions of the backside of the LE10 Radio ReceiverConnecting ports Connection compartmentMode Description Switch number Mode selectionMode indication after power on Enter programming mode ProgrammingProgram a transmitter in modes 1, 2 or To start programmingTo start deleting Delete a transmitterDelete all transmitters Program a door address in modes 3 or Programming in modes 6 orOperation Standby modeNormal mode modes 1 Dementia mode Activation of a MIYS37L Wristband TransmitterDetection of a MIYS37E Wristband Transmitter alone Activation of a programmed transmitter Dementia with Accompany modeRemote control mode Daily message with battery-low signal Open receiver modes 6Daily messages in modes 1, 2 or Activation of a transmitter in the reception rangeStandby Extended MIYN46 mode 8, only with SWReset of a battery-low indication with button T1 Battery low indication until the battery is exchanged Dual channel receiver mode 9, only with SWBattery-low indication Technical data ABSBosch Security Systems