TDK 5KW Dvc?, Filter?, Out?, Fld?, Fbd ?, Fbdrst, Ovp?, Ovm, Uvl?, Ast?, Sav, Rcl

Page 65

#

Command

 

Description

 

 

Display Voltage and Current data. Data will be returned as a string of ASCII

 

 

characters. A comma will separate the different fields. The fields, in order, are:

7

DVC?

Measured Voltage, Programmed Voltage, Measured Current, Programmed Cur-

 

 

rent, Over Voltage Set Point and Under Voltage Set Point.

 

 

Example: 5.9999,6.0000,010.02,010.00,7.500,0.000

8

FILTER

Set the low pass filter frequency of the A to D Converter for Voltage and Current

nn

Measurement where nn = 18, 23 or 46.

 

9

FILTER?

Returns the A to D Converter filter frequency: 18,23 or 46 Hz.

 

 

Turns the output to ON or OFF. Recover from Safe-Start, OVP or FLD fault.

10

OUT n

OUT 1 (or OUT ON)-Turn On.

 

 

OUT 0 (or OUT OFF)-Turn Off

11

OUT?

Returns the output On/Off status string.

 

 

ON - output On. OFF - output Off.

12

FLD n

Sets the Foldback protection to ON or OFF.

 

 

FLD 1 (or FOLD ON) - Arms the Foldback protection

 

 

FLD 0 (or FOLD OFF) - Cancels the Foldback protection.

 

 

When the Foldback protection has been activated, OUT 1 command will release

 

 

the protection and re-arm it, while FLD 0 will cancel the protection.

13

FLD?

Returns the Foldback protection status string:

“ON” - Foldback is armed. “OFF” - Foldback is cancelled.

 

 

14

FBD nn

Add (nn x 0.1) seconds to the Fold Back Delay. This delay is in addition to the

standard delay. The range of nn is 0 to 255. The value is stored in eprom at AC

 

 

power down and recovered at AC power up.

15

FBD ?

Supply returns the value of the added Fold Back Delay.

16

FBDRST

Reset the added Fold Back Delay to zero.

 

 

Sets the OVP level. The OVP setting range is given in Table 7-7. The number of

 

 

characters after OVP is up to 12. The minimum setting level is approximately

17

OVP n

105% of the Output Voltage setting, or the value in Table 7-7, whichever is

higher. The maximum OVP setting level is shown in Table 5-1. Attempting to

 

 

 

 

program the OVP below this level will result in an execution error response

 

 

(“E04”). The OVP setting stays unchanged.

18

OVP?

Returns the setting “n” where “n” is the exact string in the user’s “OVP n”. When

in Local mode, returns the last setting from the front panel in a 4 digit string.

 

 

19

OVM

Sets OVP level to the maximum level. Refer to Table 7-7.

20

UVL n

Sets Under Voltage Limit. Value of “n” may be equal to PV setting, but returns

“E06” if higher. Refer to Table 7-8 for UVL programming range.

 

 

21

UVL?

Returns the setting “n” where “n” is the exact string in the user’s “UVL n”. When

in Local mode, returns the last setting from the front panel in a 4 digit string.

 

 

 

 

Sets the Auto-restart mode to ON or OFF.

22

AST n

AST 1 (or AST ON): Auto restart On.

 

 

AST 0 (or AST OFF): Auto restart Off.

23

AST?

Returns the string auto-restart mode status.

24

SAV

Saves present settings. The settings are the same as power-down last setting.

These settings are erased when the supply power is switched Off and the new

 

 

“last settings” are saved.

25

RCL

Recalls

last settings. Settings are from the last power-down or from the last

“SAV”

command.

 

 

 

 

 

57

83-515-000 Rev. B

Image 65
Contents 2U Genesystm 5kW Page Page Genesys Manual Supplement Table of Contents Front and Rear Panel Controls and Connectors ……………… Remote Analog PROGRAMMING……………………………………………… Isolated Analog Progamming OPTION………………………………… Warranty Service Limitation of WarrantyDisclaimer Trademark InformationSafety Instructions FCC Compliance Notice Environmental ConditionsSICHERHEITS-INSTALLATIONS Anweisungen Anderungen and Bauteileersatz Sicherheits-und WarnsymboleSICHERHEITS-HINWEISE UmweltbedingungenGeneral Information Features and optionsIntroduction General DescriptionControl via the serial communication port Multiple output power systemAnalog voltage programming and monitoring Parallel operationAccessories Specifications 83-515-000 Rev. B Supplemental Characteristics Genesystm 5000W Power Supplies Outline Drawings General InstallationPreparation for USE Initial InspectionsRack Mounting To install the Power Supply in a rackLOCATION, Mounting and Cooling AC Source RequirementsAC Input Connector AC Input Power ConnectionAC Input Wire Connection AC Input CordStripped Wires installed in Strain Relief Prior to Operation TURN-ON Checkout ProcedureConstant Voltage Check Constant Current CheckBaud Rate Setting RS-232 and RS-485 only Address SettingUVL Check Foldback CheckLoad Wiring Connecting the LoadCurrent Carrying Capacity AWGInductive loads Wire terminationNoise and Impedance Effects Making the load connections 8V to 100V Models Load wires connection, 8V to 100V models 83-515-000 Rev. B Connecting multiple loads, radial distribution method Connecting single loads, local sensing defaultConnecting single loads, remote sensing Grounding outputs Multiple load connection with distribution terminalsLocal and Remote Sensing Sense wiringOutput Terminal Grounding Local sensingRepackaging for Shipment 10.4 J2 sense connector technical informationRemote sensing Front Panel Controls and Indicators Front and Rear Panel Controls and ConnectorsSection Rear Panel Connections and Controls SW1 setup DIP-switch Rear Panel SW1 Setup Switch1 SW1 position function Resetting the SW1 switchMaking J1 connections Rear Panel J1 Programming and Monitoring ConnectorEnain SignalIfcom LocalConstant Current Mode Constant Voltage ModeLocal Operation IntroductionResetting the OVP circuit Setting the OVP levelAutomatic Crossover Over Voltage Protection OVP4A Under Voltage Limit UVL Output SHUT-OFF SO Control VIA Rear Panel J1 ConnectorFoldback Protection Output ON/OFF ControlPsok Signal ENABLE/DISABLE Control VIA Rear Panel J1 ConnectorCV/CC Signal Last Setting Memory Over Temperature Protecton OTPSAFE-START and AUTO-RESTART Modes Series OperationSeries connection, local sensing Series connection for increased output voltageSeries connection for positive/negative output voltages Series connection for positive and negative output voltageParallel Operation Setting the units as Master or Slave Advanced parallel configurationMaster and Slave units default operation Connection to the loadAST OFF *OUT OFF To release units from Slave modeCurrent display accuracy Front Panel Locking DAISY-CHAIN ConnectionUnlocked front panel Locked front panelLOCAL/REMOTE Analog Indication Remote Analog ProgrammingLOCAL/REMOTE Analog Control J1 connector, rear panel view Remote resistive programming Resisitive Programming of Output Voltage and Current LimitRemote Monitoring of Output Voltage and Current Configuration RS232 & RS485 Remote ControlFront panel in Remote mode Rear Panel RS232/RS485 Connector6 RS232/RS485 port in Local mode MD Mode enable Serial communication mode MD Mode DescriptionMD Mode SRQ MD Mode SRQ RetransmissionSingle power supply Connecting Power Supplies to RS232 or RS485 BUSCommunication Interface Protocol Command SET Description Error MessagesOutput Control Commands Initialization Control CommandsID Control Commands Filter DVC?FILTER? OUT?General Global Output CommandsEnable MD Mode MD Mode Option Required Single Byte CommandsDisable SRQ retransmission MD Mode Option Required Enable SRQ retransmission MD Mode Option RequiredPrint Power On Time Addressed commands with response Read registersTest if MD Mode is Installed Addressed commands without response Acknowledge SRQ1010 None Disable retransmission of SRQs by sup Voltage programming range Status Control Commands STATUS, Error and SRQ RegistersStatus Registers Conditional RegistersFold BITFault Event Register Service Request Enable and Event RegistersFault Enable Register Status Event Register Status Enable RegisterCommunication Test Power supply set-upSerial Communication Test SET-UP Isolated Analog Programming Option Specifications1 0-5V/0-10V Option PN IS510 PPM/CIsolated Programming & Monitoring Connector Setup and Operating Instructions Maintenance OUP Fuse Rating

5KW specifications

The TDK 5KW is a cutting-edge power supply solution designed to deliver high performance and efficiency in a compact form. This robust unit is engineered for various applications, including industrial automation, telecommunications, and renewable energy systems. With a focus on reliability and durability, the TDK 5KW is an excellent choice for users seeking a dependable power source.

One of the standout features of the TDK 5KW is its advanced power conversion technology. It utilizes a high-frequency switching technique that allows for superior efficiency, minimizing energy loss and reducing heat generation. By operating at high efficiency levels, the TDK 5KW helps lower operational costs while contributing to a greener environment.

The power supply is equipped with a wide input voltage range, making it suitable for global applications. It can accept input voltages from 90 to 264 VAC, ensuring versatility and compatibility with various electrical systems. This feature also enhances its usability in different geographic regions without the need for additional transformers or converters.

Another significant characteristic of the TDK 5KW is its modular design, which allows for easy integration into existing systems. The power supply features a compact footprint, making it ideal for installations where space is at a premium. Moreover, its robust construction ensures that it can withstand harsh operating conditions, including extreme temperatures and vibrations.

Reliability is further enhanced through built-in protection features, including overvoltage, overcurrent, and short-circuit protection. These safety mechanisms not only safeguard the power supply itself but also protect the connected equipment from damage, making it a trustworthy choice for critical applications.

The TDK 5KW also supports various communication protocols, enabling seamless integration into modern automation systems. This feature allows for real-time monitoring and control, providing users with essential data to optimize performance and troubleshoot issues efficiently.

In summary, the TDK 5KW is a powerful, efficient, and reliable power supply solution that caters to a broad range of applications. Its advanced technologies, modular design, and robust safety features make it an essential component for anyone looking to enhance their electrical systems with a high-quality power source.