SUPER MICRO Computer X7DCL-3, X7DCL-i Core-Multi-Processing Available if supported by the CPU

Page 69

Chapter 4: BIOS

Core-Multi-Processing (Available if supported by the CPU.)

Set to Enabled to use a processor's Second Core and beyond. (Please refer to Intel's web site for more information.) The options are Disabled and Enabled.

Machine Checking (Available when supported by the CPU.)

Set to Enabled to activate the function of Machine Checking and allow the CPU to detect and report hardware (machine) errors via a set of model-specific registers (MSRs). The options are Disabled and Enabled.

Thermal Management 2 (Available if supported by the CPU.)

Set to Enabled to use Thermal Management 2 (TM2) which will lower CPU voltage and frequency when the CPU temperature reaches a predefined overheat threshold. Set to Disabled to use Thermal Manager 1 (TM1), allowing CPU clocking to be regulated via CPU Internal Clock modulation when the CPU temperature reaches

the overheat threshold.

C1 Enhanced Mode (Available if supported by the CPU.)

Set to Enabled to enable Enhanced Halt State to lower CPU voltage/frequency to prevent overheat. The options are Enabled and Disabled. (Note: please refer to Intel’s web site for detailed information.)

Execute Disable Bit (Available if supported by the CPU and the OS.)

Set to Enabled to enable Execute Disable Bit and allow the processor to classify areas in memory where an application code can execute and where it cannot, and thus preventing a worm or a virus from inserting and creating a flood of codes to overwhelm the processor or damage the system during an attack. This feature is available when your OS and your CPU support the function of Execute Disable Bit. The options are Disabled and Enabled. Note: For more information regarding hardware/software support for this function, please refer to Intel's and Microsoft's web sites.

Adjacent Cache Line Prefetch (Available when supported by the CPU.)

The CPU fetches the cache line for 64 bytes if this option is set to Disabled. The CPU fetches both cache lines for 128 bytes as comprised if Enabled. The options are Disabled and Enabled.

Hardware Prefetcher (Available when supported by the CPU.)

Set to this option to enabled to enable the hardware components that are used in conjunction with software programs to prefetch data in order to shorten execution cycles and maximize data processing efficiency. The options are Disabled and Enabled.

4-13

Image 69
Contents Super Page About This Manual Manual OrganizationConventions Used in the Manual Table of Contents Table of Contents Bios TroubleshootingIntroduction Running Setup Advanced SetupOverview ChecklistHeadquarters Contacting SupermicroEurope Asia-PacificX7DCL-3/X7DCL-i Image Not drawn to scale X7DCL-3/X7DCL-i Motherboard LayoutLED Indicator Description Jumper Description Default SettingQuick Reference X7DCL-3/X7DCL-i JPA1 NoteMemory Motherboard FeaturesChipset Expansion SlotsDimensions Acpi FeaturesOnboard I/O OtherMCH Block Diagram of the Intel 5100 ChipsetChipset and Processor Features Overview 5100 Memory Controller Hub MCHNinth Generation I/O Controller Hub ICH9 PC Health Monitoring Special FeaturesSlow Blinking LED for Suspend-State Indicator Acpi FeaturesMain Switch Override Mechanism External Modem Ring-OnSuper I/O Power SupplyPage Page Precautions Static-Sensitive DevicesUnpacking Installing the LGA771 Processor Processor and Heatsink Fan InstallationLoading the Processor into the Socket To Remove the Heatsink Installing the HeatsinkInstalling DIMMs Dimm InstallationMounting the Motherboard in the Chassis Dimm 1A Dimm 2A Memory SupportDimm 1A Dimm 1B Dimm 2A Dimm 2B Dimm 1A Dimm 1B Dimm 1C Dimm 2A Dimm 2B Dimm 2CInstalling and Removing DIMMs To RemovePossible System Memory Allocation & Availability Back Panel Connectors/IO Ports Control Panel Connectors/IO PortsPower LED JF1 Header PinsPower Button Front Control PanelFront Control Panel Pin Definitions Power LEDNMI Button NMI PWR LEDHDD LED NIC1 LED NIC2 LED NIC1/NIC2 LED IndicatorsPower Fail LED Overheat/Fan Fail LED OHOH/Fan Fail LED B. PWR Supply Fail Power Button Reset ButtonReset Button PWR Button Reset Button Pin Definitions JF1ATX Power Connector Connecting CablesProcessor Power Connector Required ConnectionBackpanel USB 0/1 Front Panel USB 2/3 Front Panel USB 4/5 Universal Serial Bus USBBack Panel USB 0/1 Pin Definitions Front Panel USB Pin Definitions USB2/3/4/5Chassis Intrusion Fan HeadersFan Chassis Intrusion Fan Header Pin Definitions Fan1-6Serial Ports ATX PS/2 Keyboard and PS/2 Mouse PortsKeyboard/Mouse COM1 COM2Wake-On-LAN Wake-On-RingWOR WOL Wake-On-Ring Pin DefinitionsSpeaker Connector Power LED/SpeakerGlan 1/2 Giga-bit Ethernet Ports GLAN1 GLAN2PWR Supply Failure/PWR Fault Detect Alarm ResetAlarm Reset PWR FaultGpio Headers VGA ConnectorVGA J7 SATAGPIO#0 J8 SATAGPIO#1 J9 SASGPIO#0 J10 SASGPIO#1BP PWR SMB I2C Connector Power SMB I2C ConnectorPWR SMB Backplane PWR SMBKeylock KeylockKeylock Pin Definitions Glan Enable/Disable Jumper SettingsGlan Port1 Enable B. Glan Port2 Enable Glan Enable Jumper SettingsClear Cmos Watch Dog Enable Watch Dog Enable/DisableWatch Dog Jumper Settings Cmos ClearVGA Enable/Disable Jumper Settings VGA Enable/DisableI2C Bus to PCI/PCI-Exp. Slots JPI2C1 C. JPI2C2Software RAID Enable SAS Enable/DisableSAS Enabled Software RAID Enable SAS Enable/Disable Jumper SettingsOnboard Power LED LED3 Onboard LED IndicatorsGlan LEDs LEDSystem Status LED LED4 Cpuvrm Overheating LED Indicators LED5/LED6LED4 System Status LED LED5 CPU1VRM OH LED LED6 CPU2VRM OH LEDLED1 SAS LED SAS LED Indicator LED1Floppy Connector Floppy Drive, Simlc Ipmi and Hard Disk Drive ConnectionsFloppy Disk Drive IDE Connector Simlc Ipmi SlotIDE Simlc Before Power On Troubleshooting ProceduresNo Power Losing the System’s Setup ConfigurationMemory Errors Technical Support ProceduresFrequently Asked Questions Question Whats on the CD that came with my motherboard? Returning Merchandise for ServiceHow To Change the Configuration Data System BiosStarting the Setup Utility IntroductionRunning Setup Main Bios SetupPress the Delete key to enter Setup Main Setup Features Main Bios Setup MenuSATA Port 1 ~ Sata Port 6, Ext. Primary Master/Slave LBA Mode ControlType Multi-Sector TransfersUltra DMA Mode Transfer ModeNative Mode Operation Sata Controller ModeSata Ahci Enable System MemoryExtended Memory Advanced Setup Power Loss Control Power Button BehaviorMemory Cache Cache System Bios Area Cache Video Bios AreaCache Base 512K-640K Cache Base 0-512KCache Extended Memory Discrete Mtrr AllocationOnboard GLAN-1/Onboard GLAN-2 Gigabit- LAN Oprom Configure PCI ConfigurationOnboard Storage Oprom Configure Reset Configuration DataCrystal Beach Configure Enable Clock Spectrum FeatureSerr Signal Condition Advanced Chipset ControlDemand Scrubbing Enable Multi-Media TimerPatrol Scrubbing Route Port 80h Cycles toMachine Checking Available when supported by the CPU C1 Enhanced Mode Available if supported by the CPUHardware Prefetcher Available when supported by the CPU Core-Multi-Processing Available if supported by the CPUCPU Cache Control I/O Device ConfigurationIntel Eist Support Available if supported by the CPU KBC Clock InputInterrupt Base I/O AddressSerial Port B ModeECC Event Logging Event LoggingMark DMI Events as Read Clear All DMI Event LogsCPU Overheat Alarm CPU1 Temperature/CPU2 TemperatureHardware Monitor System Temperature Fan1-Fan6 Speeds Fan Speed Control ModesVoltage Monitoring Clear System Event Logging System Event LoggingExisting Event Log Number Event Log ControlBios Post Watch Dog System Event Log/System Event Log List ModeOS Boot Watch Dog Timer for Loading OS MinutesRealtime Sensor Data IPMI LAN ConfigurationUser Password Is Supervisor Password IsSet Supervisor Password Set User PasswordBoot Password on BootBoot Priority Order/Excluded from Boot Orders Exit Recoverable Post Error Beep Codes Appendix a Post Error Beep CodesPage Appendix B Installing the Windows OS Page Driver/Tool Installation Display Screen Installing other Drivers and the OSConfiguring Supero Doctor Supero Doctor III Interface Display Screen-II Remote Control