Seagate ST336807FC manual Reliability and service

Page 30

5.1.2Unrecoverable errors

Unrecoverable Data Errors (Sense Key = 03h) are specified at less than 1 sector in error per 1015 bits trans- ferred. Unrecoverable Data Errors resulting from the same cause are treated are 1 error for that block.

5.1.3Seek errors

A seek error is defined as a failure of the drive to position the heads to the addressed track. After detecting an initial seek error, the drive automatically performs an error recovery process. If the error recovery process fails, a seek positioning error (Error code = 15h or 02h) will be reported with a Hardware error (04h) in the Sense Key. Recoverable seek errors are specified at Less than 10 errors in 108 seeks. Unrecoverable seek errors (Sense Key = 04h) are classified as drive failures.

5.1.4Interface errors

An interface error is defined as a failure of the receiver on a port to recover the data as transmitted by the device port connected to the receiver. The error may be detected as a running disparity error, illegal code, loss of word sync, or CRC error. The total error rate for a loop of devices is the sum of the individual device error rates.

5.2Reliability and service

You can enhance the reliability of Cheetah 10K.7 SCSI disc drives by ensuring that the drive receives ade- quate cooling. Section 6.0 provides temperature measurements and other information that may be used to enhance the service life of the drive. Section 8.3 provides recommended air-flow information.

5.2.1Annualized Failure Rate (AFR)

The production disc drive shall achieve an AFR of 0.62% when operated in an environment that ensures the HDA case temperatures specified in Section 6.4 are not exceeded. Short-term excursions up to the specifica- tion limits of the operating environment will not affect AFR performance. Continual or sustained operation at case temperatures above the values shown in Section 6.4.1 may degrade product reliability.

Estimated power-on operation hours means power-up hours per disc drive times the total number of disc drives in service. Each disc drive shall have accumulated at least nine months of operation. Data shall be cal- culated on a rolling average base for a minimum period of six months.

AFR is based on the following assumptions:

8,760 power-on hours per year.

250 average on/off cycles per year.

Operations at nominal voltages.

Systems will provide adequate cooling to ensure the case temperatures specified in Section 6.4.1 are not exceeded.

Drive failure means any stoppage or substandard performance caused by drive malfunction.

A S.M.A.R.T. predictive failure indicates that the drive is deteriorating to an imminent failure and is considered an AFR hit.

5.2.2Preventive maintenance

No routine scheduled preventive maintenance is required.

18

Cheetah 10K.7 36GB FC Product Manual, Rev. A

Image 30
Contents Cheetah 10K.7 FC Page Cheetah 10K.7 FC Page Revision status summary sheet Rev. a 05/04/05 All. Initial releaseRevision Date Sheets Affected Page Contents Installation Physical/electrical specificationsDefect and error management Interface requirementsSeagate Technology support services Viii Cheetah 10K.7 36GB FC Product Manual, Rev. a List of Figures Cheetah 10K.7 FC family disc driveCheetah 10K.7 36GB FC Product Manual, Rev. a Scope Cheetah 10K.7 FC family disc driveCheetah 10K.7 36GB FC Product Manual, Rev. a Electromagnetic compatibility Applicable standards and reference documentationStandards Electromagnetic susceptibilityElectromagnetic compliance European Union Restriction of Hazardous Substances RoHSReference documents Fibre Channel Interface ManualCheetah 10K.7 36GB FC Product Manual, Rev. a General description Standard features Media descriptionFormatted capacities PerformanceReliability Programmable drive capacityFactory-installed accessories Factory-installed optionsUser-installed accessories Performance characteristics Internal drive characteristicsST336807FC Format command execution time in minutes Seek performance characteristicsAccess time Generalized performance characteristicsStart/stop time Prefetch/multi-segmented cache controlCache operation Caching write data Prefetch operation Cheetah 10K.7 36GB FC Product Manual, Rev. a Reliability specifications Error ratesRecoverable Errors Reliability and service Hot plugging the drive 4 S.M.A.R.TControlling S.M.A.R.T Reporting control Performance impactMilliseconds Determining rateTemperature Log page 0Dh Parameter Code DescriptionDrive Self Test DST Implementation State of the drive prior to testingDST Failure Definition Invoking DSTExtended test Function Code 010b Product warrantyShort test Function Code 001b Log page entriesShipping Product repair and return informationDC power requirements Physical/electrical specificationsAC power requirements ST336807FC DC power requirementsGeneral DC power requirement notes Power sequencingConducted noise immunity Typical ST336807FC drive, 2 Gbit, +12V current profile Typical ST336807FC drive, 2 Gbit, +5V current profilePower dissipation ST336807FCRelative humidity TemperatureEnvironmental limits Effective altitude sea levelPackage size Packaged/product weight Drop height Shock and vibrationShock Recommended mounting Air cleanliness VibrationCorrosive environment Mechanical specifications AcousticsMounting configuration dimensions Defect and error management Drive internal defects/errorsDrive error recovery procedures 77.7 FC-AL system errors Background Media ScanMedia Pre-Scan Cheetah 10K.7 36GB FC Product Manual, Rev. a Installation Drive ID/option selectionLED connections Physical interface Drive Front1 J6 connector requirements Drive orientationCooling Drive mounting GroundingLink services supported FC-AL featuresFibre Channel link service frames Type of frame Link serviceFibre Channel task management responses Fibre Channel task management functionsFibre Channel Scsi FCP task management functions FC Scsi FCP response codesFibre Channel port login NPort login Plogi payloadBytes Fibre Channel Process Login Fibre Channel port login acceptNPort Login Accept ACC payload Process Login Plri payloadFibre Channel fabric login Fibre Channel Process Login AcceptProcess Login Accept ACC payload Fabric Login Flogi payloadFibre Channel fabric accept login Fabric Login Accept ACC payloadFC-AL options supported Dual port supportFibre Channel Arbitrated Loop options Option SupportedScsi commands supported Supported commandsCommand code Supported Command name Supported commands Supported commands Supported commands Supported commands Cheetah 10K.7 FC inquiry data Mode Sense dataInquiry data Bytes Data hexPage DEF CHG Supported Feature or condition Miscellaneous operating features and conditionsMiscellaneous features Miscellaneous statusPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Part description Positions Part number FeaturesJ6 connector dimensions Electrical descriptionPin Signal name Signal type Pin descriptionsFC-SCA pin descriptions Power Fault LED OutFC-AL transmitters and receivers Active LED Out Enable port bypass signalsNormal command activity LED status Active LED Out conditionsMotor start controls Motor start control signalsParallel Enclosure Services Interface ESI 11 SEL6 through SEL0 ID linesSetting Arbitrated loop physical address Alpa valuesHex Dec Signal characteristics Differential Pecl output characteristics LED driver signalsLED drive signal Differential Pecl input characteristicsEye diagram data values Link rate GHzCheetah 10K.7 36GB FC Product Manual, Rev. a Presales Support Seagate Technology support servicesInternet MySeagate Reseller.seagate.com Technical SupportWarranty Service Data Recovery Services Authorized Service CentersData Recovery Services FAX services-All Europe toll call Call center Presales and Technical Support Warranty ServiceToll-free support numbers Asia/Pacific support services Publication feedback survey Cheetah 10K.7 36GB FC Product Manual, Rev. a Index NumericsFAN Flogi PBC Page See also cooling