Table 12 equates the read and write retry count with the maximum possible recovery time for read and write recovery of individual LBAs. The times given do not include time taken to perform reallocations. Reallocations are performed when the ARRE bit (for reads) or AWRE bit (for writes) is one, the RC bit is zero, and the recov- ery time limit for the command has not yet been met. Time needed to perform reallocation is not counted against the recovery time limit.

When the RC bit is one, reallocations are disabled even if the ARRE or AWRE bits are one. The drive will still perform data recovery actions within the limits defined by the Read Retry Count, Write Retry Count, and Recovery Time Limit parameters. However, the drive does not report any unrecovered errors.

Table 12: Read and write retry count maximum recovery times

Read retry

Maximum recovery time per

count1

LBA (cumulative, msec)

0

77.7

 

 

1

89.7

 

 

2

305.0

 

 

3

352.8

 

 

4

400.7

 

 

5

418.6

 

 

6

466.4

 

 

7

586.0

 

 

8

675.7

 

 

9

723.5

 

 

10

777.3

 

 

11

1,064.4

 

 

12

1,877.66 (default)

 

 

Write retry

Maximum recovery time per

count1

LBA (cumulative, msec)

0

35.9

 

 

1

53.8

 

 

2

83.7

 

 

3

101.7

 

 

4

179.4

 

 

5

424.6 (default)

 

 

[1]These values are subject to change.

Setting these retry counts to a value below the default setting could result in an increased unrecovered error rate which may exceed the value given in this product manual. A setting of zero (0) will result in the drive not performing error recovery.

For example, suppose the Read/Write Recovery page has the RC bit set to 0, read retry count set to 4, and the recovery time limit field (Mode Sense page 01, bytes 10 and 11) set to FF FF hex (maximum). A four LBA Read command is allowed to take up to 400.7 msec recovery time for each of the four LBAs in the command. If the recovery time limit is set to 00 C8 hex (200 msec decimal) a four LBA read command is allowed to take up to 200 msec for all error recovery within that command. The use of the Recovery Time Limit field allows finer granularity on control of the time spent in error recovery. The recovery time limit only starts counting when the drive is executing error recovery and it restarts on each command. Therefore, each command’s total recovery time is subject to the recovery time limit. Note: A recovery time limit of 0 will use the drive’s default value of FF FF. Minimum recovery time limit is achieved by setting the Recovery Time Limit field to 00 01.

36

Cheetah 10K.7 36GB FC Product Manual, Rev. A

Image 48
Contents Cheetah 10K.7 FC Page Cheetah 10K.7 FC Page Revision status summary sheet Rev. a 05/04/05 All. Initial releaseRevision Date Sheets Affected Page Contents Physical/electrical specifications Defect and error managementInstallation Interface requirementsSeagate Technology support services Viii Cheetah 10K.7 36GB FC Product Manual, Rev. a List of Figures Cheetah 10K.7 FC family disc driveCheetah 10K.7 36GB FC Product Manual, Rev. a Scope Cheetah 10K.7 FC family disc driveCheetah 10K.7 36GB FC Product Manual, Rev. a Applicable standards and reference documentation StandardsElectromagnetic compatibility Electromagnetic susceptibilityElectromagnetic compliance European Union Restriction of Hazardous Substances RoHSReference documents Fibre Channel Interface ManualCheetah 10K.7 36GB FC Product Manual, Rev. a General description Standard features Media descriptionPerformance ReliabilityFormatted capacities Programmable drive capacityFactory-installed accessories Factory-installed optionsUser-installed accessories Performance characteristics Internal drive characteristicsST336807FC Seek performance characteristics Access timeFormat command execution time in minutes Generalized performance characteristicsStart/stop time Prefetch/multi-segmented cache controlCache operation Caching write data Prefetch operation Cheetah 10K.7 36GB FC Product Manual, Rev. a Reliability specifications Error ratesRecoverable Errors Reliability and service Hot plugging the drive 4 S.M.A.R.TControlling S.M.A.R.T Performance impact MillisecondsReporting control Determining rateTemperature Log page 0Dh Parameter Code DescriptionDrive Self Test DST State of the drive prior to testing DST Failure DefinitionImplementation Invoking DSTProduct warranty Short test Function Code 001bExtended test Function Code 010b Log page entriesShipping Product repair and return informationPhysical/electrical specifications AC power requirementsDC power requirements ST336807FC DC power requirementsGeneral DC power requirement notes Power sequencingConducted noise immunity Typical ST336807FC drive, 2 Gbit, +12V current profile Typical ST336807FC drive, 2 Gbit, +5V current profilePower dissipation ST336807FCTemperature Environmental limitsRelative humidity Effective altitude sea levelPackage size Packaged/product weight Drop height Shock and vibrationShock Recommended mounting Air cleanliness VibrationCorrosive environment Mechanical specifications AcousticsMounting configuration dimensions Defect and error management Drive internal defects/errorsDrive error recovery procedures 77.7 FC-AL system errors Background Media ScanMedia Pre-Scan Cheetah 10K.7 36GB FC Product Manual, Rev. a Installation Drive ID/option selectionLED connections Physical interface Drive Front1 J6 connector requirements Drive orientationCooling Drive mounting GroundingFC-AL features Fibre Channel link service framesLink services supported Type of frame Link serviceFibre Channel task management functions Fibre Channel Scsi FCP task management functionsFibre Channel task management responses FC Scsi FCP response codesFibre Channel port login NPort login Plogi payloadBytes Fibre Channel port login accept NPort Login Accept ACC payloadFibre Channel Process Login Process Login Plri payloadFibre Channel Process Login Accept Process Login Accept ACC payloadFibre Channel fabric login Fabric Login Flogi payloadFibre Channel fabric accept login Fabric Login Accept ACC payloadDual port support Fibre Channel Arbitrated Loop optionsFC-AL options supported Option SupportedScsi commands supported Supported commandsCommand code Supported Command name Supported commands Supported commands Supported commands Supported commands Mode Sense data Inquiry dataCheetah 10K.7 FC inquiry data Bytes Data hexPage DEF CHG Miscellaneous operating features and conditions Miscellaneous featuresSupported Feature or condition Miscellaneous statusPhysical characteristics FC-AL physical interfacePhysical description Connector requirements Part description Positions Part number FeaturesJ6 connector dimensions Electrical descriptionPin Signal name Signal type Pin descriptionsFC-SCA pin descriptions Power Fault LED OutFC-AL transmitters and receivers Enable port bypass signals Normal command activity LED statusActive LED Out Active LED Out conditionsMotor start control signals Parallel Enclosure Services Interface ESIMotor start controls 11 SEL6 through SEL0 ID linesSetting Arbitrated loop physical address Alpa valuesHex Dec Signal characteristics LED driver signals LED drive signalDifferential Pecl output characteristics Differential Pecl input characteristicsEye diagram data values Link rate GHzCheetah 10K.7 36GB FC Product Manual, Rev. a Seagate Technology support services Internet MySeagate Reseller.seagate.comPresales Support Technical SupportWarranty Service Data Recovery Services Authorized Service CentersData Recovery Services FAX services-All Europe toll call Call center Presales and Technical Support Warranty ServiceToll-free support numbers Asia/Pacific support services Publication feedback survey Cheetah 10K.7 36GB FC Product Manual, Rev. a Index NumericsFAN Flogi PBC Page See also cooling