Seagate ST336807FC manual Installation, Drive ID/option selection

Page 51

8.0Installation

Cheetah 10K.7 FC disc drive installation is a plug-and-play process. There are no jumpers, switches, or termi- nators on the drive. Simply plug the drive into the host’s 40-pin Fibre Channel backpanel connector (FC- SCA)no cables are required. See Section 9.5 for additional information about this connector.

Use the FC-AL interface to select drive ID and all option configurations for devices on the loop.

If multiple devices are on the same FC-AL and physical addresses are used, set the device selection IDs (SEL IDs) on the backpanel so that no two devices have the same selection ID. This is called the hard assigned arbi- trated loop physical address (AL_PA). There are 125 AL_PAs available (see Table 31). If you set the AL_PA on the backpanel to any value other than 0, the device plugged into the backpanel’s SCA connector inherits this AL_PA. In the event you don’t successfully assign unique hard addresses (and therefore have duplicate selec- tion IDs assigned to two or more devices), the FC-AL generates a message indicating this condition. If you set the AL_PA on the backpanel to a value of 0, the system issues a unique soft-assigned physical address auto- matically.

Loop initialization is the process used to verify or obtain an address. The loop initialization process is per- formed when power is applied to the drive, when a device is added or removed from the Fibre Channel loop, or when a device times out attempting to win arbitration.

Set all option selections in the connector prior to applying power to the drive. If you change options after applying power to the drive, recycle the drive power to activate the new settings.

It is not necessary to low-level format this drive. The drive is shipped from the factory low-level formatted in 512-byte logical blocks. You need to reformat the drive only if you want to select a different logical block size.

8.1Drive ID/option selection

All drive options are made through the interface connector (J1). Table provides the pin descriptions for the 40- pin Fibre Channel single connector (J1).

Cheetah 10K.7 36GB FC Product Manual, Rev. A

39

Image 51
Contents Cheetah 10K.7 FC Page Cheetah 10K.7 FC Page Revision status summary sheet Rev. a 05/04/05 All. Initial releaseRevision Date Sheets Affected Page Contents Interface requirements Physical/electrical specificationsDefect and error management InstallationSeagate Technology support services Viii Cheetah 10K.7 36GB FC Product Manual, Rev. a Cheetah 10K.7 FC family disc drive List of FiguresCheetah 10K.7 36GB FC Product Manual, Rev. a Cheetah 10K.7 FC family disc drive ScopeCheetah 10K.7 36GB FC Product Manual, Rev. a Electromagnetic susceptibility Applicable standards and reference documentationStandards Electromagnetic compatibilityEuropean Union Restriction of Hazardous Substances RoHS Electromagnetic complianceFibre Channel Interface Manual Reference documentsCheetah 10K.7 36GB FC Product Manual, Rev. a General description Media description Standard featuresProgrammable drive capacity PerformanceReliability Formatted capacitiesFactory-installed accessories Factory-installed optionsUser-installed accessories Performance characteristics Internal drive characteristicsST336807FC Generalized performance characteristics Seek performance characteristicsAccess time Format command execution time in minutesStart/stop time Prefetch/multi-segmented cache controlCache operation Caching write data Prefetch operation Cheetah 10K.7 36GB FC Product Manual, Rev. a Reliability specifications Error ratesRecoverable Errors Reliability and service Hot plugging the drive 4 S.M.A.R.TControlling S.M.A.R.T Determining rate Performance impactMilliseconds Reporting controlTemperature Log page 0Dh Parameter Code DescriptionDrive Self Test DST Invoking DST State of the drive prior to testingDST Failure Definition ImplementationLog page entries Product warrantyShort test Function Code 001b Extended test Function Code 010bProduct repair and return information ShippingST336807FC DC power requirements Physical/electrical specificationsAC power requirements DC power requirementsGeneral DC power requirement notes Power sequencingConducted noise immunity Typical ST336807FC drive, 2 Gbit, +5V current profile Typical ST336807FC drive, 2 Gbit, +12V current profileST336807FC Power dissipationEffective altitude sea level TemperatureEnvironmental limits Relative humidityPackage size Packaged/product weight Drop height Shock and vibrationShock Recommended mounting Air cleanliness VibrationCorrosive environment Acoustics Mechanical specificationsMounting configuration dimensions Defect and error management Drive internal defects/errorsDrive error recovery procedures 77.7 FC-AL system errors Background Media ScanMedia Pre-Scan Cheetah 10K.7 36GB FC Product Manual, Rev. a Drive ID/option selection InstallationPhysical interface Drive Front LED connections1 J6 connector requirements Drive orientationCooling Grounding Drive mountingType of frame Link service FC-AL featuresFibre Channel link service frames Link services supportedFC Scsi FCP response codes Fibre Channel task management functionsFibre Channel Scsi FCP task management functions Fibre Channel task management responsesFibre Channel port login NPort login Plogi payloadBytes Process Login Plri payload Fibre Channel port login acceptNPort Login Accept ACC payload Fibre Channel Process LoginFabric Login Flogi payload Fibre Channel Process Login AcceptProcess Login Accept ACC payload Fibre Channel fabric loginFabric Login Accept ACC payload Fibre Channel fabric accept loginOption Supported Dual port supportFibre Channel Arbitrated Loop options FC-AL options supportedScsi commands supported Supported commandsCommand code Supported Command name Supported commands Supported commands Supported commands Supported commands Bytes Data hex Mode Sense dataInquiry data Cheetah 10K.7 FC inquiry dataPage DEF CHG Miscellaneous status Miscellaneous operating features and conditionsMiscellaneous features Supported Feature or conditionPhysical characteristics FC-AL physical interfacePhysical description Part description Positions Part number Features Connector requirementsElectrical description J6 connector dimensionsPin Signal name Signal type Pin descriptionsFC-SCA pin descriptions Power Fault LED OutFC-AL transmitters and receivers Active LED Out conditions Enable port bypass signalsNormal command activity LED status Active LED Out11 SEL6 through SEL0 ID lines Motor start control signalsParallel Enclosure Services Interface ESI Motor start controlsSetting Arbitrated loop physical address Alpa valuesHex Dec Signal characteristics Differential Pecl input characteristics LED driver signalsLED drive signal Differential Pecl output characteristicsLink rate GHz Eye diagram data valuesCheetah 10K.7 36GB FC Product Manual, Rev. a Technical Support Seagate Technology support servicesInternet MySeagate Reseller.seagate.com Presales SupportWarranty Service Data Recovery Services Authorized Service CentersData Recovery Services FAX services-All Europe toll call Call center Presales and Technical Support Warranty ServiceToll-free support numbers Asia/Pacific support services Publication feedback survey Cheetah 10K.7 36GB FC Product Manual, Rev. a Numerics IndexFAN Flogi PBC Page See also cooling