9.1.2Fibre Channel task management functions

Table 14 lists the Fibre Channel SCSI Fibre Channel Protocol (FC SCSI FCP) task management functions sup- ported.

Table 14:

Fibre Channel SCSI FCP task management functions

 

 

 

 

Task name

 

Supported

 

 

 

Terminate task

No

 

 

 

 

 

 

Clear ACA

 

No

 

 

 

 

 

 

Target reset

 

Yes

 

 

 

 

 

Clear task set

Yes

 

 

 

 

 

Abort task set

Yes

 

 

 

 

 

 

9.1.3Fibre Channel task management responses

Table 15 lists the FC SCSI FCP response codes returned for task management functions supported.

Table 15: FC SCSI FCP response codes

Function name

Response code

 

 

Function complete

00

 

 

 

Function not supported

04

 

 

 

Function reject

05

 

 

 

44

Cheetah 10K.7 36GB FC Product Manual, Rev. A

Image 56
Contents Cheetah 10K.7 FC Page Cheetah 10K.7 FC Page Revision Date Sheets Affected Revision status summary sheetRev. a 05/04/05 All. Initial release Page Contents Physical/electrical specifications Defect and error managementInstallation Interface requirementsSeagate Technology support services Viii Cheetah 10K.7 36GB FC Product Manual, Rev. a List of Figures Cheetah 10K.7 FC family disc driveCheetah 10K.7 36GB FC Product Manual, Rev. a Scope Cheetah 10K.7 FC family disc driveCheetah 10K.7 36GB FC Product Manual, Rev. a Applicable standards and reference documentation StandardsElectromagnetic compatibility Electromagnetic susceptibilityElectromagnetic compliance European Union Restriction of Hazardous Substances RoHSReference documents Fibre Channel Interface ManualCheetah 10K.7 36GB FC Product Manual, Rev. a General description Standard features Media descriptionPerformance ReliabilityFormatted capacities Programmable drive capacityUser-installed accessories Factory-installed accessoriesFactory-installed options ST336807FC Performance characteristicsInternal drive characteristics Seek performance characteristics Access timeFormat command execution time in minutes Generalized performance characteristicsCache operation Start/stop timePrefetch/multi-segmented cache control Caching write data Prefetch operation Cheetah 10K.7 36GB FC Product Manual, Rev. a Recoverable Errors Reliability specificationsError rates Reliability and service Controlling S.M.A.R.T Hot plugging the drive4 S.M.A.R.T Performance impact MillisecondsReporting control Determining rateDrive Self Test DST Temperature Log page 0DhParameter Code Description State of the drive prior to testing DST Failure DefinitionImplementation Invoking DSTProduct warranty Short test Function Code 001bExtended test Function Code 010b Log page entriesShipping Product repair and return informationPhysical/electrical specifications AC power requirementsDC power requirements ST336807FC DC power requirementsConducted noise immunity General DC power requirement notesPower sequencing Typical ST336807FC drive, 2 Gbit, +12V current profile Typical ST336807FC drive, 2 Gbit, +5V current profilePower dissipation ST336807FCTemperature Environmental limitsRelative humidity Effective altitude sea levelShock Package size Packaged/product weight Drop heightShock and vibration Recommended mounting Corrosive environment Air cleanlinessVibration Mechanical specifications AcousticsMounting configuration dimensions Drive error recovery procedures Defect and error managementDrive internal defects/errors 77.7 Media Pre-Scan FC-AL system errorsBackground Media Scan Cheetah 10K.7 36GB FC Product Manual, Rev. a Installation Drive ID/option selectionLED connections Physical interface Drive FrontCooling 1 J6 connector requirementsDrive orientation Drive mounting GroundingFC-AL features Fibre Channel link service framesLink services supported Type of frame Link serviceFibre Channel task management functions Fibre Channel Scsi FCP task management functionsFibre Channel task management responses FC Scsi FCP response codesBytes Fibre Channel port loginNPort login Plogi payload Fibre Channel port login accept NPort Login Accept ACC payloadFibre Channel Process Login Process Login Plri payloadFibre Channel Process Login Accept Process Login Accept ACC payloadFibre Channel fabric login Fabric Login Flogi payloadFibre Channel fabric accept login Fabric Login Accept ACC payloadDual port support Fibre Channel Arbitrated Loop optionsFC-AL options supported Option SupportedCommand code Supported Command name Scsi commands supportedSupported commands Supported commands Supported commands Supported commands Supported commands Mode Sense data Inquiry dataCheetah 10K.7 FC inquiry data Bytes Data hexPage DEF CHG Miscellaneous operating features and conditions Miscellaneous featuresSupported Feature or condition Miscellaneous statusPhysical description Physical characteristicsFC-AL physical interface Connector requirements Part description Positions Part number FeaturesJ6 connector dimensions Electrical descriptionFC-SCA pin descriptions Pin Signal name Signal typePin descriptions FC-AL transmitters and receivers PowerFault LED Out Enable port bypass signals Normal command activity LED statusActive LED Out Active LED Out conditionsMotor start control signals Parallel Enclosure Services Interface ESIMotor start controls 11 SEL6 through SEL0 ID linesHex Dec SettingArbitrated loop physical address Alpa values Signal characteristics LED driver signals LED drive signalDifferential Pecl output characteristics Differential Pecl input characteristicsEye diagram data values Link rate GHzCheetah 10K.7 36GB FC Product Manual, Rev. a Seagate Technology support services Internet MySeagate Reseller.seagate.comPresales Support Technical SupportData Recovery Services Warranty ServiceData Recovery Services Authorized Service Centers Toll-free support numbers FAX services-All Europe toll callCall center Presales and Technical Support Warranty Service Asia/Pacific support services Publication feedback survey Cheetah 10K.7 36GB FC Product Manual, Rev. a Index NumericsFAN Flogi PBC Page See also cooling