Seagate ST336807FC manual Motor start controls, Motor start control signals

Page 77

9.5.10Motor start controls

The drive’s motor is started according to the Start_1 and Start_2 signals described in Table 30. The state of these signals can be wired into the backplane socket or driven by logic on the backplane.

Table 30:

Motor start control signals

 

 

 

 

 

Case

 

Start_2

Start_1

Motor spin function

 

 

 

 

 

1

 

Low

Low

Motor spins up at DC power on.

 

 

 

 

 

2

 

High

Low

Motor spins up only when SCSI Start command is received.

 

 

 

 

 

3

 

Low

High

Motor spins up after a delay of 12 seconds times the modulo 8 value of

 

 

 

 

the numeric SEL ID of the drive from DC power on.

 

 

 

 

 

4

 

High

High

The drive will not spin up.

 

 

 

 

 

9.5.11SEL_6 through SEL_0 ID lines

The SEL_6 through SEL_0 ID lines determine drive address, and, optionally, for an Enclosure Services Inter- face. When the Parallel ESI line is high, the enclosure backpanel must provide address information on the SEL line. Refer to table 31 for a mapping of SEL to FC-AL physical addresses (AL_PA). You can think of the SEL lines as the equivalent of a backpanel logic plug. The drives does not provide pull up resistors on these lines. The backpanel is required to provide high and low inputs to the SEL_ID lines per the specifications in table 33 on page 67.

Note. Table 31 gives AL_PA values for each SEL value. The first entry in the table is SEL_ID 00. The last entry is SEL_ID 7D. SEL_ID 7E is AL_PA 00 which is not valid for an NL_Port, so is not included in the table. Also, SEL_ID 7Fh does map to a valid AL_PA; however, this value signals the drive that physical addresses are not being assigned using the SEL lines and that a “soft” address will be determined by FC-AL loop initialization.

When the Parallel ESI line is low, the enclosure backpanel logic switches to ESI mode if supported. There are two modes of ESI, seven bits of enclosure status and a bidirectional mode. ESI support and the mode are determined by the drive using a discovery process. Refer to the Fibre Channel Interface Manual for a descrip- tion of ESI operation.

9.5.11.1Parallel Enclosure Services Interface (ESI)

The parallel ESI line is an output from the drive. This line provides the enclosure with an indication of the present function of the SEL lines. A high level, the default state, indicates the drive requires address informa- tion on the SEL lines. A low level indicates the drive is attempting an ESI transfer. The enclosure may not sup- port ESI on any or all drive locations. It may only support the address function. Support of ESI is discovered by the drive. Refer to the Fibre Channel Interface Manual for a description of ESI operations.

Cheetah 10K.7 36GB FC Product Manual, Rev. A

65

Image 77
Contents Cheetah 10K.7 FC Page Cheetah 10K.7 FC Page Revision Date Sheets Affected Revision status summary sheetRev. a 05/04/05 All. Initial release Page Contents Defect and error management Physical/electrical specificationsInstallation Interface requirementsSeagate Technology support services Viii Cheetah 10K.7 36GB FC Product Manual, Rev. a Cheetah 10K.7 FC family disc drive List of FiguresCheetah 10K.7 36GB FC Product Manual, Rev. a Cheetah 10K.7 FC family disc drive ScopeCheetah 10K.7 36GB FC Product Manual, Rev. a Standards Applicable standards and reference documentationElectromagnetic compatibility Electromagnetic susceptibilityEuropean Union Restriction of Hazardous Substances RoHS Electromagnetic complianceFibre Channel Interface Manual Reference documentsCheetah 10K.7 36GB FC Product Manual, Rev. a General description Media description Standard featuresReliability PerformanceFormatted capacities Programmable drive capacityUser-installed accessories Factory-installed accessoriesFactory-installed options ST336807FC Performance characteristicsInternal drive characteristics Access time Seek performance characteristicsFormat command execution time in minutes Generalized performance characteristicsCache operation Start/stop timePrefetch/multi-segmented cache control Caching write data Prefetch operation Cheetah 10K.7 36GB FC Product Manual, Rev. a Recoverable Errors Reliability specificationsError rates Reliability and service Controlling S.M.A.R.T Hot plugging the drive4 S.M.A.R.T Milliseconds Performance impactReporting control Determining rateDrive Self Test DST Temperature Log page 0DhParameter Code Description DST Failure Definition State of the drive prior to testingImplementation Invoking DSTShort test Function Code 001b Product warrantyExtended test Function Code 010b Log page entriesProduct repair and return information ShippingAC power requirements Physical/electrical specificationsDC power requirements ST336807FC DC power requirementsConducted noise immunity General DC power requirement notesPower sequencing Typical ST336807FC drive, 2 Gbit, +5V current profile Typical ST336807FC drive, 2 Gbit, +12V current profileST336807FC Power dissipationEnvironmental limits TemperatureRelative humidity Effective altitude sea levelShock Package size Packaged/product weight Drop heightShock and vibration Recommended mounting Corrosive environment Air cleanlinessVibration Acoustics Mechanical specificationsMounting configuration dimensions Drive error recovery procedures Defect and error managementDrive internal defects/errors 77.7 Media Pre-Scan FC-AL system errorsBackground Media Scan Cheetah 10K.7 36GB FC Product Manual, Rev. a Drive ID/option selection InstallationPhysical interface Drive Front LED connectionsCooling 1 J6 connector requirementsDrive orientation Grounding Drive mountingFibre Channel link service frames FC-AL featuresLink services supported Type of frame Link serviceFibre Channel Scsi FCP task management functions Fibre Channel task management functionsFibre Channel task management responses FC Scsi FCP response codesBytes Fibre Channel port loginNPort login Plogi payload NPort Login Accept ACC payload Fibre Channel port login acceptFibre Channel Process Login Process Login Plri payloadProcess Login Accept ACC payload Fibre Channel Process Login AcceptFibre Channel fabric login Fabric Login Flogi payloadFabric Login Accept ACC payload Fibre Channel fabric accept loginFibre Channel Arbitrated Loop options Dual port supportFC-AL options supported Option SupportedCommand code Supported Command name Scsi commands supportedSupported commands Supported commands Supported commands Supported commands Supported commands Inquiry data Mode Sense dataCheetah 10K.7 FC inquiry data Bytes Data hexPage DEF CHG Miscellaneous features Miscellaneous operating features and conditionsSupported Feature or condition Miscellaneous statusPhysical description Physical characteristicsFC-AL physical interface Part description Positions Part number Features Connector requirementsElectrical description J6 connector dimensions FC-SCA pin descriptions Pin Signal name Signal type Pin descriptions FC-AL transmitters and receivers PowerFault LED Out Normal command activity LED status Enable port bypass signalsActive LED Out Active LED Out conditionsParallel Enclosure Services Interface ESI Motor start control signalsMotor start controls 11 SEL6 through SEL0 ID linesHex Dec SettingArbitrated loop physical address Alpa values Signal characteristics LED drive signal LED driver signalsDifferential Pecl output characteristics Differential Pecl input characteristicsLink rate GHz Eye diagram data valuesCheetah 10K.7 36GB FC Product Manual, Rev. a Internet MySeagate Reseller.seagate.com Seagate Technology support servicesPresales Support Technical SupportData Recovery Services Warranty ServiceData Recovery Services Authorized Service Centers Toll-free support numbers FAX services-All Europe toll callCall center Presales and Technical Support Warranty Service Asia/Pacific support services Publication feedback survey Cheetah 10K.7 36GB FC Product Manual, Rev. a Numerics IndexFAN Flogi PBC Page See also cooling