2.0Applicable standards and reference documentation

The drive has been developed as a system peripheral to the highest standards of design and construction. The drive depends upon its host equipment to provide adequate power and environment in order to achieve opti- mum performance and compliance with applicable industry and governmental regulations. Special attention must be given in the areas of safety, power distribution, shielding, audible noise control, and temperature regu- lation. In particular, the drive must be securely mounted in order to guarantee the specified performance char- acteristics. Mounting by bottom holes must meet the requirements of Section 8.5.

2.1Standards

The Cheetah 10K.7 FC family complies with Seagate standards as noted in the appropriate sections of this manual and the Seagate Fibre Channel Interface Manual, part number 77767496.

The Cheetah 10K.7 FC disc drive is a UL recognized component per UL1950, CSA certified to CAN/CSA C22.2 No. 950-95, and VDE certified to VDE 0805 and EN60950.

2.1.1Electromagnetic compatibility

The drive, as delivered, is designed for system integration and installation into a suitable enclosure prior to use. As such the drive is supplied as a subassembly and is not subject to Subpart B of Part 15 of the FCC Rules and Regulations nor the Radio Interference Regulations of the Canadian Department of Communica- tions.

The design characteristics of the drive serve to minimize radiation when installed in an enclosure that provides reasonable shielding. As such, the drive is capable of meeting the Class B limits of the FCC Rules and Regula- tions of the Canadian Department of Communications when properly packaged. However, it is the user’s responsibility to assure that the drive meets the appropriate EMI requirements in their system. Shielded I/O cables may be required if the enclosure does not provide adequate shielding. If the I/O cables are external to the enclosure, shielded cables should be used, with the shields grounded to the enclosure and to the host con- troller.

2.1.2Electromagnetic susceptibility

As a component assembly, the drive is not required to meet any susceptibility performance requirements. It is the responsibility of those integrating the drive within their systems to perform those tests required and design their system to ensure that equipment operating in the same system as the drive or external to the system does not adversely affect the performance of the drive. See Section Table 11, DC power requirements.

Cheetah 10K.7 36GB FC Product Manual, Rev. A

3

Image 15
Contents Cheetah 10K.7 FC Page Cheetah 10K.7 FC Page Revision status summary sheet Rev. a 05/04/05 All. Initial releaseRevision Date Sheets Affected Page Contents Interface requirements Physical/electrical specificationsDefect and error management InstallationSeagate Technology support services Viii Cheetah 10K.7 36GB FC Product Manual, Rev. a Cheetah 10K.7 FC family disc drive List of FiguresCheetah 10K.7 36GB FC Product Manual, Rev. a Cheetah 10K.7 FC family disc drive ScopeCheetah 10K.7 36GB FC Product Manual, Rev. a Electromagnetic susceptibility Applicable standards and reference documentationStandards Electromagnetic compatibilityEuropean Union Restriction of Hazardous Substances RoHS Electromagnetic complianceFibre Channel Interface Manual Reference documentsCheetah 10K.7 36GB FC Product Manual, Rev. a General description Media description Standard featuresProgrammable drive capacity PerformanceReliability Formatted capacitiesFactory-installed accessories Factory-installed optionsUser-installed accessories Performance characteristics Internal drive characteristicsST336807FC Generalized performance characteristics Seek performance characteristicsAccess time Format command execution time in minutesStart/stop time Prefetch/multi-segmented cache controlCache operation Caching write data Prefetch operation Cheetah 10K.7 36GB FC Product Manual, Rev. a Reliability specifications Error ratesRecoverable Errors Reliability and service Hot plugging the drive 4 S.M.A.R.TControlling S.M.A.R.T Determining rate Performance impactMilliseconds Reporting controlTemperature Log page 0Dh Parameter Code DescriptionDrive Self Test DST Invoking DST State of the drive prior to testingDST Failure Definition ImplementationLog page entries Product warrantyShort test Function Code 001b Extended test Function Code 010bProduct repair and return information ShippingST336807FC DC power requirements Physical/electrical specificationsAC power requirements DC power requirementsGeneral DC power requirement notes Power sequencingConducted noise immunity Typical ST336807FC drive, 2 Gbit, +5V current profile Typical ST336807FC drive, 2 Gbit, +12V current profileST336807FC Power dissipationEffective altitude sea level TemperatureEnvironmental limits Relative humidityPackage size Packaged/product weight Drop height Shock and vibrationShock Recommended mounting Air cleanliness VibrationCorrosive environment Acoustics Mechanical specificationsMounting configuration dimensions Defect and error management Drive internal defects/errorsDrive error recovery procedures 77.7 FC-AL system errors Background Media ScanMedia Pre-Scan Cheetah 10K.7 36GB FC Product Manual, Rev. a Drive ID/option selection InstallationPhysical interface Drive Front LED connections1 J6 connector requirements Drive orientationCooling Grounding Drive mountingType of frame Link service FC-AL featuresFibre Channel link service frames Link services supportedFC Scsi FCP response codes Fibre Channel task management functionsFibre Channel Scsi FCP task management functions Fibre Channel task management responsesFibre Channel port login NPort login Plogi payloadBytes Process Login Plri payload Fibre Channel port login acceptNPort Login Accept ACC payload Fibre Channel Process LoginFabric Login Flogi payload Fibre Channel Process Login AcceptProcess Login Accept ACC payload Fibre Channel fabric loginFabric Login Accept ACC payload Fibre Channel fabric accept loginOption Supported Dual port supportFibre Channel Arbitrated Loop options FC-AL options supportedScsi commands supported Supported commandsCommand code Supported Command name Supported commands Supported commands Supported commands Supported commands Bytes Data hex Mode Sense dataInquiry data Cheetah 10K.7 FC inquiry dataPage DEF CHG Miscellaneous status Miscellaneous operating features and conditionsMiscellaneous features Supported Feature or conditionPhysical characteristics FC-AL physical interfacePhysical description Part description Positions Part number Features Connector requirementsElectrical description J6 connector dimensionsPin Signal name Signal type Pin descriptionsFC-SCA pin descriptions Power Fault LED OutFC-AL transmitters and receivers Active LED Out conditions Enable port bypass signalsNormal command activity LED status Active LED Out11 SEL6 through SEL0 ID lines Motor start control signalsParallel Enclosure Services Interface ESI Motor start controlsSetting Arbitrated loop physical address Alpa valuesHex Dec Signal characteristics Differential Pecl input characteristics LED driver signalsLED drive signal Differential Pecl output characteristicsLink rate GHz Eye diagram data valuesCheetah 10K.7 36GB FC Product Manual, Rev. a Technical Support Seagate Technology support servicesInternet MySeagate Reseller.seagate.com Presales SupportWarranty Service Data Recovery Services Authorized Service CentersData Recovery Services FAX services-All Europe toll call Call center Presales and Technical Support Warranty ServiceToll-free support numbers Asia/Pacific support services Publication feedback survey Cheetah 10K.7 36GB FC Product Manual, Rev. a Numerics IndexFAN Flogi PBC Page See also cooling