Western Telematic PLS-345 manual Status Screens, Circuit Status Screen

Page 35

6.The Status Screens

The PLS Status Screens are used to display current conditions of the three switched A/B circuits and the network interface. There are two status screens; the Circuit Status Screen (/S), and the Network Status Screen (/SN).

6.1. The Circuit Status Screen

The Circuit Status Screen lists the current A/B settings for the PLS-345's three switched circuits, and also summarizes user- selected parameters, such as Command Echo, Inactivity Timeout, and Command Confirmation.

As shown in Figure 6.1, the Circuit Status Screen lists the following items:

1.Site ID Message: The currently defined Site ID message. Note that the site ID message is defined via the General Parameters Menu (/G).

2.Ckt #: The circuit numbers for the PLS's three A/B circuits.

Physical Layer Switch v1.00

Site ID: PLS-345_TEST_IRVINE_CALIFORNIA

CKT#

From

To

POS MON Default

-----+

------------------

+------------------

+

-----

+

-----

+

---------

1

COMMON_LINE_1

LINE_B1

B

 

A

2

COMMON_LINE_2

LINE_A2

A

*

A

3

COMMON_LINE_3

LINE_A3

A

*

A

-----+

------------------

+------------------

+

-----

+

-----

+

---------

Command Echo:

On

 

 

 

 

 

 

 

Inactivity Timeout:

30 Min

 

 

 

 

 

 

 

Command Confirmation:

On

 

 

 

 

 

 

 

Automated Mode:

Off

 

 

 

 

 

 

 

Monitor Mode:

On

 

 

 

 

 

 

 

Monitor Input Level:

1 - High

 

 

 

 

 

 

 

"/H" for help.

Figure 6.1: The Circuit Status Screen

6-1

Image 35
Contents PLS-345 Page Shock Hazard Do Not Enter Nameplate Power WarningVentilation Enclosed RacksTable of Contents Application Examples Command SummaryIntroduction Monitor ModeApplications Typographic ConventionsFront Panel Unit DescriptionBack Panel Back PanelUnit Description PLS-345 Physical Layer Switch Users Guide Quick Start / System Overview $ telnet 192.168.168.168 Enter Modem & Console Port Access Factory set PLSCircuit Status Screen Command Help Screen System Mode Initialization InstallationPower Supply Connection Connecting a PC to the Console Port Connecting Common and A/B LinesConnecting the Network Cable Connecting an External ModemSystem Mode and User Mode SetUp and ConfigurationCommunicating with the PLS-345 SetUp and Configuration PLS Command/Menu Conventions Defining General Parameters SetUp and ConfigurationPLS-345 Physical Layer Switch Users Guide SetUp and Configuration Circuit Parameters Menu Circuit ParametersNetwork Parameters Network Parameters Menu IP Security Implementing IP SecurityExample 1 Deny access to all hosts except Selecting Monitor Mode Parameters Monitor ModeHardware Configuration Monitor Mode Parameters Menu Switch if Level 1 High Switch to Position B Return On Save Configuration Parameters Circuit Status Screen Status ScreensPLS-345 Physical Layer Switch Users Guide Port Network Status ScreenPLS-345 Physical Layer Switch Users Guide Operation Manual A/B SwitchingEnter Code Activated A/B Switching/A Command and the /B Command Enter or /B n EnterCommand Confirmation Prompt /D CommandMonitor Mode Sending Parameters to a File Saving and Restoring Configuration ParametersRestoring Saved Parameters Application Examples Monitoring Signal Drop and/or Power LossAUX Port Connection Monitoring a Contact Monitoring a Switch or RelayItem 6 Circuits to Switch Enable the Monitor Mode at circuit Display Circuit Status Command SummaryDisplay Commands Display Help ScreenView/Set Circuit Parameters Configuration CommandsSN Display Network Status View/Set General ParametersView/Set Network Parameters View/Set Monitor Mode ParametersDL Download Configuration to File Switch Circuit n to Line B Control CommandsSwitch Circuit n to Line a Command Format /T Enter Command Arguments Set Circuits to DefaultReset Network Interface Command Format /D Enter Command ArgumentsExit/Disconnect Command Format /X Enter Command ArgumentsModem Port Interface Interface DescriptionsConsole Port Interface Figure A.3 Common Ports and A/B Ports Common Ports and A/B PortsSize SpecificationsSwitching Trademark and Copyright Information Customer ServiceIndex Index-2 Page Sterling Irvine California 949 586-9950 Toll Free