Operation

6.4. The Automated Mode

The Automated Mode allows the IPS to execute switching and reboot commands, without displaying menus or generating response messages. Automated Mode is designed to allow the IPS to be controlled by a device which can generate commands to control power switching functions without human intervention.

When Automated Mode is enabled, the /ON, /OFF, /BOOT, /D and /X commands are executed without a "Sure?" confirmation prompt and without command response messages; the only reply to these commands is the "IPS>" prompt, which is displayed when the command is complete.

Note that although Automated Mode can be enabled using either the Web Browser Interface or Text Interface, Automated Mode is designed primarily for users who wish to send ASCII commands to the IPS without operator intervention, and therefore does not specifically apply to the Web Browser Interface. When Automated Mode is enabled, the Web Browser Interface can still be used to invoke On / Off / Boot commands.

Notes:

When Automated Mode is enabled, all IPS password security functions are disabled, and users are able to access System Level command functions (including the configuration menus) and control plugs without entering a password.

If you need to enable the Automated Mode, but want to restrict network access to IPS configuration menus, it is recommended to enable and configure the IP Security Function as described in Section 5.3.4.1.

To enable/disable Automated Mode, access the General Parameters menu (see Section 5.3.1,) then set the "Automated Mode" option to "On". When Automated Mode is enabled, IPS functions will change as follows:

1.All Password Security Suppressed: When a user attempts to access command mode, the password prompt will not be displayed at either the COM / RS232 Port or the Network Port. Unless specifically restricted by the IP Security Function, all users will be allowed to access both switching and configuration functions, and all commands will be immediately accepted without the requirement to enter a password.

2.Status Screen Suppressed: The status screens will not be automatically displayed after commands are successfully executed. Note however, that the /S command can still be invoked to display the status screen as needed.

6-7

Image 45
Contents Models User’s GuidePage Installation Instructions FCC Part 15 Regulation Table of Contents List of Figures Introduction Typographic Conventions IPS-800-D20, IPS-800E-D20, IPS-1600-D20 IPS-1600E-D20 UnitsIPS-800-D20 Back Panel 120 VAC Model Shown Unit DescriptionIPS-800/1600-D20 Series User’s Guide Hardware Installation Apply Power to the IPSQuick Start Connect your PC to the IPS Communicating with the IPSText Interface Text Interface Type /X and press Enter Installation Power Supply ConnectionInstalling the Cable Keepers IPS-800 Series Cable Keeper Installation Connection to Switched OutletsConnecting a Local PC Connecting the Network CableConnecting an External Modem Serial COM / RS232 Port ConnectionIPS-800/1600-D20 Series User’s Guide System Mode and User Mode ConfigurationPlug Status Screen Web Browser Interface IPS-800-D20 Shown Accessing the Web Browser InterfaceAccessing the Text Interface $ telnet 192.168.168.168 Enter Configuration Menus General Parameters Menu Web Browser Interface General Parameters MenusGeneral Parameters Menu Text Interface IPS-800/1600-D20 Series User’s Guide Serial Parameters Serial Parameters MenuIPS-800/1600-D20 Series User’s Guide Plug #1 Parameters Plug Parameters MenusPlug Passwords and Co-Location Features Reboot Cycles Network Parameters Menu Web Browser Interface Network Parameters Menus IP Security Feature Confi guration 12 Telnet Parameters Menu Web Browser Interface Telnet Parameters Menus14 Web Server Parameters Menu Web Browser Interface Web Server Parameters MenusSave Configuration Parameters Operation Operation via the Web Browser InterfacePlug Status Screen Web Browser Interface Plug Status Menu Web Browser Interface IPS-800-D20 Shown Plug Status Screen Text Interface Operation via the Text InterfaceIPS Help Screen Text Interface Switching and Reboot Commands Text InterfaceBoot 1 or /BO Atmswtch Applying Commands to Several Plugs Text Interface Logging Out of Command ModeAutomated Mode Manual Operation Sending Parameters to a File Saving and Restoring Configuration ParametersRestoring Saved Parameters Upgrading the IPS Firmware IPS-800/1600-D20 Series User’s Guide Interface Description Serial COM / RS232 Port InterfaceApx-1 Apx-2 SpecificationsApx-3 Customer ServiceApx-4 Trademark and Copyright InformationIndex-1 IndexIndex-2 Page Sterling Irvine California 949 586-9950 Toll Free