2. Unit Description

As shown in Figure 2.1 and Figure 2.2, the IPS back panel includes connectors, LEDs and manual controls described below:

1

8

9

BUS

A

B

A-1

A-2

A-3

A-4

 

 

 

 

MAIN POWER

COM

 

B-5

B-6

B-7

B-8

DEF ON RDY

10BaseT

ACT

 

 

 

 

 

 

2

3

4

5

6

7

Figure 2.1: IPS-800-D20 Back Panel (120 VAC Model Shown)

1

 

 

 

 

3

 

 

 

8

9

 

 

 

 

 

 

 

 

 

 

MAIN POWER

BUS

A-1

A-2

A-3

A-4

A-5

A-6

A-7

A-8

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COM

BUS

B-9

B-10

B-11

B-12

B-13

B-14

B-15

B-16

DEF

ON RDY

ACT

B

 

 

10BaseT

2

 

 

 

 

4

 

 

 

5

6

7

Figure 2.2: IPS-1600-D20 Back Panel (120 VAC Model Shown)

Bus "A" Power Inlet and Circuit Breaker: An IEC320-C20 AC inlet and circuit breaker which supply power to the Circuit "A" outlets. Also includes cable keeper (not shown.)

Models IPS-800-D20 & IPS-1600-D20: Power Inlet and 20 Amp Circuit Breaker.

Models IPS-800E-D20 & IPS-1600E-D20: Power Inlet and 20 Amp Circuit Breaker.

Bus "B" Power Inlet and Circuit Breaker: An IEC320-C20 AC inlet and circuit breaker which supply power to the Circuit "B" outlets. Also includes cable keeper (not shown.) Includes the same components listed in Item 1 above.

2-1

Image 9
Contents Models User’s GuidePage Installation Instructions FCC Part 15 Regulation Table of Contents List of Figures Introduction Typographic Conventions IPS-800-D20, IPS-800E-D20, IPS-1600-D20 IPS-1600E-D20 UnitsIPS-800-D20 Back Panel 120 VAC Model Shown Unit DescriptionIPS-800/1600-D20 Series User’s Guide Hardware Installation Apply Power to the IPSQuick Start Connect your PC to the IPS Communicating with the IPSText Interface Text Interface Type /X and press Enter Installation Power Supply ConnectionInstalling the Cable Keepers IPS-800 Series Cable Keeper Installation Connection to Switched OutletsConnecting a Local PC Connecting the Network CableConnecting an External Modem Serial COM / RS232 Port ConnectionIPS-800/1600-D20 Series User’s Guide System Mode and User Mode ConfigurationPlug Status Screen Web Browser Interface IPS-800-D20 Shown Accessing the Web Browser InterfaceAccessing the Text Interface $ telnet 192.168.168.168 Enter Configuration Menus General Parameters Menu Web Browser Interface General Parameters MenusGeneral Parameters Menu Text Interface IPS-800/1600-D20 Series User’s Guide Serial Parameters Serial Parameters MenuIPS-800/1600-D20 Series User’s Guide Plug #1 Parameters Plug Parameters MenusPlug Passwords and Co-Location Features Reboot Cycles Network Parameters Menu Web Browser Interface Network Parameters Menus IP Security Feature Confi guration 12 Telnet Parameters Menu Web Browser Interface Telnet Parameters Menus14 Web Server Parameters Menu Web Browser Interface Web Server Parameters MenusSave Configuration Parameters Operation Operation via the Web Browser InterfacePlug Status Screen Web Browser Interface Plug Status Menu Web Browser Interface IPS-800-D20 Shown Plug Status Screen Text Interface Operation via the Text InterfaceIPS Help Screen Text Interface Switching and Reboot Commands Text InterfaceBoot 1 or /BO Atmswtch Applying Commands to Several Plugs Text Interface Logging Out of Command ModeAutomated Mode Manual Operation Sending Parameters to a File Saving and Restoring Configuration ParametersRestoring Saved Parameters Upgrading the IPS Firmware IPS-800/1600-D20 Series User’s Guide Interface Description Serial COM / RS232 Port InterfaceApx-1 Apx-2 SpecificationsApx-3 Customer ServiceApx-4 Trademark and Copyright InformationIndex-1 IndexIndex-2 Page Sterling Irvine California 949 586-9950 Toll Free