3. Quick Start

This Quick Start Guide describes a simplified installation procedure for the IPS-800-D20, IPS-800E-D20, IPS-1600-D20 or IPS-1600E-D20 hardware, which will allow you to communicate with the unit in order to demonstrate basic features and check for proper operation.

Note that this Quick Start Guide does not provide a detailed description of unit configuration or discuss advanced operating features. For more information, please refer to the Installation, Configuration and Operation sections in this User's Guide.

3.1.Hardware Installation

3.1.1.Apply Power to the IPS

Refer to power rating nameplate on the IPS back panel, and then connect the unit to an appropriate power source. Note that the IPS features two separate AC inputs and two separate power busses; connect the power cables (supplied with the unit) to the unit's Circuit "A" and Circuit "B" Power Inlets, install the cable keepers, then connect the cables to an appropriate power source. Refer to the table below for information concerning power requirements and maximum loads.

Model

Total

Input

Max. Load

Max. Load

Max. Load

Number

Outlets

Voltage

per Outlet

per Bus

per Unit

 

 

 

 

 

 

IPS-800-D20

8

100 to

15 Amps

20 Amps

40 Amps

 

 

120 VAC

 

 

 

IPS-800E-D20

8

100 to

15 Amps

20 Amps

40 Amps

 

 

240 VAC

 

 

 

 

 

 

 

 

 

IPS-1600-D20

16

100 to

15 Amps

20 Amps

40 Amps

 

 

120 VAC

 

 

 

IPS-1600E-D20

16

100 to

15 Amps

20 Amps

40 Amps

 

 

240 VAC

 

 

 

Set the Main Power Switch in the ON position; the ON LED should light, and the RDY LED should begin to flash.

3-1

Image 11
Contents Models User’s GuidePage Installation Instructions FCC Part 15 Regulation Table of Contents List of Figures Introduction Typographic Conventions IPS-800-D20, IPS-800E-D20, IPS-1600-D20 IPS-1600E-D20 UnitsIPS-800-D20 Back Panel 120 VAC Model Shown Unit DescriptionIPS-800/1600-D20 Series User’s Guide Quick Start Hardware InstallationApply Power to the IPS Connect your PC to the IPS Communicating with the IPSText Interface Text Interface Type /X and press Enter Installing the Cable Keepers InstallationPower Supply Connection IPS-800 Series Cable Keeper Installation Connection to Switched OutletsSerial COM / RS232 Port Connection Connecting the Network CableConnecting a Local PC Connecting an External ModemIPS-800/1600-D20 Series User’s Guide System Mode and User Mode ConfigurationPlug Status Screen Web Browser Interface IPS-800-D20 Shown Accessing the Web Browser InterfaceAccessing the Text Interface $ telnet 192.168.168.168 Enter Configuration Menus General Parameters Menu Web Browser Interface General Parameters MenusGeneral Parameters Menu Text Interface IPS-800/1600-D20 Series User’s Guide Serial Parameters Serial Parameters MenuIPS-800/1600-D20 Series User’s Guide Plug #1 Parameters Plug Parameters MenusPlug Passwords and Co-Location Features Reboot Cycles Network Parameters Menu Web Browser Interface Network Parameters Menus IP Security Feature Confi guration 12 Telnet Parameters Menu Web Browser Interface Telnet Parameters Menus14 Web Server Parameters Menu Web Browser Interface Web Server Parameters MenusSave Configuration Parameters Plug Status Screen Web Browser Interface OperationOperation via the Web Browser Interface Plug Status Menu Web Browser Interface IPS-800-D20 Shown Plug Status Screen Text Interface Operation via the Text InterfaceIPS Help Screen Text Interface Switching and Reboot Commands Text InterfaceBoot 1 or /BO Atmswtch Applying Commands to Several Plugs Text Interface Logging Out of Command ModeAutomated Mode Manual Operation Sending Parameters to a File Saving and Restoring Configuration ParametersRestoring Saved Parameters Upgrading the IPS Firmware IPS-800/1600-D20 Series User’s Guide Apx-1 Interface DescriptionSerial COM / RS232 Port Interface Apx-2 SpecificationsApx-3 Customer ServiceApx-4 Trademark and Copyright InformationIndex-1 IndexIndex-2 Page Sterling Irvine California 949 586-9950 Toll Free