Teledyne 460H instruction manual Safety Messages

Page 2
SAFETY MESSAGES

SAFETY MESSAGES

Your safety and the safety of others is very important. We have provided many important safety messages in this manual. Please read these messages carefully.

A safety message alerts you to potential hazards that could hurt you or others. Each safety message is associated with a safety alert symbol. These symbols are found in the manual and inside the instrument. The definition of these symbols is described below:

General Warning/Caution: Refer to the instructions for details on the specific danger.

Caution: Hot Surface

Caution: Electrical Shock Hazard

Technician Symbol: All operations marked with this symbol are to be performed by qualified maintenance personnel only.

CAUTION

The monitor should only be used for the purpose and in the

manner described in this manual.

If you use the monitor in a manner other than that for which it was intended, unpredictable behavior could ensue with possibly hazardous consequences.

P/N 03662D Teledyne API Model 460H O3 Monitor Operator Manual - Page ii

Image 2
Contents EMAIL api-sales@teledyne.com MODEL 460H NEMA OZONE MONITORINSTRUCTION MANUAL 03662 Rev. D 1/8/04SAFETY MESSAGES 6.0 MAINTENANCE TABLE OF CONTENTS2.0 INSTALLATION I. 0 INTRODUCTIONAPPENDIX A - SERIAL PORT CONFIGURATION 6.2 CLEANING EXTERIOR SURFACES OF THE M460H7.0 SENSOR AND SYSTEM TROUBLESHOOTING 6.3 DEGREE OF PROTECTIONPneumatic Connections FIGURESFigure 2-1 Mounting Hole Locations Electrical ConnectionsTable 2-3 Serial Port Pins TABLESTable 2-1 Digital Status Output Pins Serial Port ConfigurationI.0 INTRODUCTION 1.1 Preface02024c 1.2 WARRANTY POLICYADVANCED POLLUTION INSTRUMENTATION DIVISION TERMS AND CONDITIONS1.3 Principle of Operation 1.4 Specifications Figure 2-1 Mounting Hole Locations 2.0 Installation2.1 Mechanical Installation 2.2 Pneumatic Connections Figure 2-2 Pneumatic Connections2.3AC Power Connection Figure 2-3 Electrical Connections 2.4 Electrical I/O Connections2.4.1 Analog Output I/O CONNECTORLabel Table 2-1 Digital Status Output Pins2.4.2 Digital Status Outputs NameInput 2.4.3 Control InputsTable 2-2 Control Inputs DescriptionFigure 2-5 Typical RS232 and RS485 Connections Table 2-3 Serial Port Pins2.4.4 RS232/RS485 Serial Communications Port RS2323.0 Startup 4.1.1 O3 readout 4.0 Operation4.1 Front Panel Display 4.1.2 Pressure Display4.2 Auto-Zero Operation 4.2.1 Auto-Zero Installation4.2.3 Auto Zero Error 4.2.2 Auto-Zero FunctionTable 5-1 Serial Port Configuration 5.1 Serial Port Configuration5.2 Command Syntax addresscommanddata1,data2#checksumCRExamples of valid Commands with data 5.3 Command SummaryExamples of valid Commands with no data Table 5-2 Serial Port Command SummarySyntax 5.4 Command Reference5.4.1 CAUTO Data Parameters Sent5.4.2 CZERO 5.4.3 DACSTEP addresso3conc#checksumCR 5.4.4 O3addressO3CR 5.4.5 SETADDR addressSETADDRnewaddressCR5.4.6 TDUMP 5.4.7 TLIST Index 5.4.8 VGETAllowable Range addressvarvalue#checksumCR#5 iirfilt = 0.4 #6 concunits = 5.4.9 VLIST1VLISTCR is index number for internal VAR See VGET for index list 5.4.10 VSETvarindex newvalueFilter Replacement Procedure 6.0 Maintenance6.2 Cleaning Exterior Surfaces of the M460H 6.1 Replacing the gas filter element7.2 Sensor OK 7.0 Sensor and System Troubleshooting7.1 Status Output Summary Table 7-1 Digital Status Outputs7.5 Cell Dirty 7.3 Invalid Reading7.4 Lamp Low Sensor 7.6 Status Output Summary TableTable 7-2 Status Output Truth Table InvalidRS232RS485 Appendix A - Serial Port ConfigurationFigure A-1 RS232/RS485 Jumpers Controller PCA#03492 Appendix B - Pneumatic Diagram